HomeMy WebLinkAboutFire Alarm System Inspection - Inspection - 300 ABBOTT STREET 12/27/2019 IMPACT FIRE SERVICES, LL 26 HAMPSHIRE DRIVE HUDSON NH 03051 : 603.293.7531 IMPACT F : 603. 89,2 1 111".GETFI RE P ROTETI Off#.COIF FIR FIDE ALARM SYSTEM INSPECTION MASTER ELECTRICIAN#: Inspected to the state adopted version of l FPA 72 MA-2 423A; NH- 1311 M WORK ORDER 17616266 DATE:12/2 2 19 08:00am EST CUSTOMER III: BILL To: SHIP To: NORTH ANDOVER PUBLIC SCHOOLS SARGENT ELEMENTARY SCHOOL ATT :ACCOUNTS PAYABLE,566 MAIN STREET 300 ABBOTT STREET NORTH AND OVER MA 01845 NORTH A lD V R MA 0184 Phone:(1978)688-9516 Contact:DREG ROBERTS Email: Phone: 978)994-6673 ANNUAL Ej SEMI ANNUAL QUARTERLY SENSITIVITY ARRIVAL TIME: a DEPARTU RE TIME:9:30am PASS FAIL A. PANEL CONFIGURATION:Honeywell S3 Series DETECTION CLASS: CLASS A: ■❑ CLASS B: El SIGNAL CIRCUIT CLASS: CLASS A: X CLASS B: ❑ A, ] ❑ PANEL L CAT II:1ST Floor Electric Room In Sprinkler Room BATTERIES: VOLTAGE NO LOAD: 12 V 1 Ah(Installed 1/19 B. Q UA lTITY: VO LTAGE LEAD: B. 2 100% __C71 ANNUNCIATOR TYPE: C. Li U REM OTE PAN EL TYPE:EVAC panel 12V 12Ah 2 Installed 2015 100% ID El TYPE:FC I Booster 12V 7A Installed 2019 100% � ❑ D. D. TYPE, : El------------------- TYPE: ❑ ❑ E. PANEL GROUND: TERM: TO: READ: E. ❑ L. F REMOTE El MASTER BOX N RADIO MASTED BOX 239 R COMMUNICATION................................... DIGITALCOMMUNICATOR: OTHER: � F. ❑ 1:1 OFF LIFE TIME: REPORTS T :North Andover FD . . 9a 9:3 ar G. 0 LINE TIME: ..REPORTS ITS TO: DUCT SINGLE G.O. PULLS ROFR FIXED SMOKES DETECTORS STATION DETECTORS SMOKE TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL In-rv .. -� - - - - 1 o - - - MINI Outside STROBE MINI HORN Horn/Strobe Speaker/strobe Visual Only Audible Only Beacon TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL CITY9 1 -- - - - Page 1 of 3 n IMPACT FIRE SERVICES, LL 20 HAMPSHIRE ]RIVE IM ACT HUDS N NH 03051 : 603.293.7531 F : 603.589.2051 FIRWWW.GETFIREPROTECTION.COM MASTER ELECTRICIAN#: FIRE ALARM SYSTEM INSPECTION Inspected to the stake adopted version of NFPA 7 MA- 3 H- '� 117 I WORK " C DATE: 1 / 12019 03:00 rr EST CUSTOMER ID: H. Explanation Failed Devices: None I. The Inspector suggests that following necessary improvements. However, these suggestions are not the result of an engineering survey. These are recommendations based on current code. None J. Adjustments or corrections made: None K. Inspection and suggested 'improvements ents were discussed with the undersigned Owner or Owner's a resent tive. FE-1 Yes F-1 No 12/2 /19 THIS IS NOT AN INVOICE CUSTOMER'S IGNAT DATE QTY P RT##�# DESCRIPTION PRICE AMOUNT ---------- CUS IT'S T NAM 1 1 /19 N S TtIM DATE Michael Rich,h, Ross Gadsby T CEMCiAN PRINTED NAME LICENSE## BILLING ADDRESS CONFIRMED Page 2 of IMPACT FIRE SERVICES,LLC 26 HAMPSHIRE DRIVE HUE3SON NH 03059 IMPACT O: 603.293.7537 F: 603.589.2051 ADDITIONAL SERVICE VVWGETFIREPROTECTION.COM FIRE INFO/INSPECTION COMMENTS MASTER ELECTRICIAN#: DEVICE INSPECTION REPORT MA-20423A; NH- 13117 M Page 3 of 3 WORK ORDER#: 17615266 DATE; CUSTOMER ID: 12/27/2019�B:OOam EST DEVICE MODEL LOCATION ZONE NOTES/COMMENTS: PASS FAIL TYPE Duct HV1 MECH ROOM SUPPLY L1 M021 Rl El Duct HV't MECH ROOM RETURN L1 M022 Rl El Duct 1ST FLOOR MUSIC STORAGE 15B HU4 RETURN L9 M034 Z El Duct 'iST FLOOR MUSIC STORAGE 15B HU4 SUPPLY L'fM035 �✓ Duet GYM STORAGE 158 HU3 SUPPLY L1M031 Rl F-1 Duct GYM STORAGE 159 HU2 SUPPLY L1M032 �✓ Duct GYM STORAGE 159 HU2 RETURN l.1MD33 Z El Duct ELECTRIC ROOM 225 HU7 SUPPLY L1 M028 �✓ Duct ELECTRIC ROOM 225 HU7 RETURN L1M027 ❑✓ Duct ELECTRIC ROOM 225 HU 6 SUPPLY L1Md26 Q✓ El Duct ELECTRIC ROOM 225 HU8 RETURN L1 M025 RI El Duct ELECTRIC ROOM 225HU5 RETURN L1 M024 � RI Duct ELECTRIC ROOM 225 HU5 SUPPLY L'4M023 z El El El El El El El El El El El El El El El El El El El El El El El E El El El E] BILLING ADDRESS CONFIRMED CUSTOMER'S SIGNATURE-DATE TECHNICIAN'S SIGNATURE-DATE CUSTOMER'S PRINTED NAME