HomeMy WebLinkAboutConstruction Notes - Consultant Review - 204 MILL ROAD 4/16/2020 North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 204 Mill Road MAP: 107A LOT: 63 INSTALLER: Todd Bateson DESIGNER: John Sullivan PLAN DATE: 5/29/19 BOH APPROVAL DATE ON PLAN: INSPECTIONS TANK INSPECTION: completed DATE OF BED BOTTOM INSPECTION: completed DATE OF FINAL CONSTRUCTION INSPECTION: 4/13/20 DATE OF FINAL GRADE INSPECTION: completed SITE CONDITIONS Contractor reports any changes to design plan Existing septic tank properly abandoned Internal plumbing all to one building sewer Topography not appreciably altered Comments: 4/13/20 – Contractor reports building sewer exiting house is slightly lower than expected but cannot be raised. SEPTIC TANK Building sewer in continuous grade, on compacted firm base Cleanouts per plan Bottom of tank hole has 6” stone base Weep hole plugged 1500 gallon tank has been installed H-10 loading Monolithic tank construction Water tightness of tank has been achieved by visual testing Inlet tee installed, centered under access port Outlet tee installed, centered under access port (effluent filter) 24" inch cover to within 6” of finish grade installed over one access port Neoprene boots around inlet & outlet Comments: 4/13/20 – H-10 tank provided, plan specifies H-20 tank. Installer reports he spoke with designer and received authorization to change. DISTRIBUTION-BOX Installed on stable stone base H-20 D-Box Inlet tee (if pumped or >0.08’/foot) Hydraulic cement around inlet & outlets Observed even distribution Speed levelers provided (not required) Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) Bottom of SAS excavated down to C soil layer, as provided on plan Size of SAS excavated as per plan Title 5 sand installed, if specified on plan 40 Mil HDPE barrier installed Laterals installed and ends connected to header (and vented if impervious material above) Elevations of laterals and chambers installed as on approved plan N/ARetaining wall (boulder / concrete / timber/ block) Final cover as per plan Comments: SOIL ABSORPTION SYSTEM (Gravel-less Chambers) Brand and Model of Chamber: Low Profile Standard Quick 4 Infiltrator Chambers Number of chambers per row: 11 Number of rows (trenches): 3 Comments: Total Chambers = _33___ FINAL GRADE Loamed Seeded Cover per plan Comments: DOCUMENTS NEEDED Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM = 99.66 HR = 3.93 HI = 103.59 SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Building Sewer OUT 7.50 95.76 96.21 Septic Tank IN 7.61 95.65 95.87 Septic Tank OUT 7.84 95.42 95.62 Distribution Box IN 8.13 95.13 95.27 Distribution Box OUT 8.31 94.95 95.10 Lateral 1 INVERT 8.36 94.90 95.07 Lateral 2 INVERT 8.38 94.88 95.07 Lateral 3 INVERT 8.34 94.92 95.07 Top of Chamber 8.30 95.29 95.49 Bottom of Bed/Chamber 8.94 94.65 94.82