Loading...
HomeMy WebLinkAboutFire Alarm Maintenance and Test Report - Correspondence - 6/26/2020 Copy For: B.B.AC.�4RM SYSTEMS ` Fire Department 3$ LAFAYETTE..ROAD...: :. 6I26/2020 ISBURY.,MA.,{f1952 DATE TESTEp 'TEL. 978-463-889� FAX 978 463-3622'. - FIRE A LA RM MA IN NA NCE & TES T REPOR T PROPERTY Chickering Properties ADDRESS 535 Checkering Road North Andover, MA .......... ........... PANEL MANUFACTURER MODEL# 72 NUMBER OF ZONES 12 Knox Box key b nx YES fy 10 ( ZONES TESTER REMOTE TROUBLE ZONES FAILED 0 INDICATOR OPERATIONAL F- YES F- NO rv-' NA SMOKE DETECTORS '. Sensitivity TOTAL Cleaned Tested Tested Failed SYSTEM SMOKES 18 17 97 9 1 COMBO SMOKE/CO 3 3 3 0 CARBON MONOXID 1 1 10 op LOCAL SMOKES ;:HEAT DETECTORS , . µ TOTAL #TESTED #FAILED RATE/RISE HEATS V �' 0 RATE ANTICIPATED FIXED TEMP RESTORABLE 7 Q FIXED TEMP NOW RESTORABLE .......... U�.L,STATIONS TOTAL #TESTED #FAILED 11 10 *0 ALARM:N4T�FICATION DF1/fCES TOTAL #TESTED #FAILED MORE!/LIGHTS HORN /STROBES. 15 7 Q INSIDE---- HORNS ........... ............. MINI HORNS/STROBES STROBES 31 0 0 HORN/LIGHTS HORN/STROBES OUTSIDE STROBES BEACONS 1110 VAC LIGHT (Above Master Box) TOTAL TESTED TESTED FIRE DOORS HVAC SHUTDOWN F- E I NO — BED SHAKERS ELEVATOR RECALL F YES F- No DEMOTE AN NUN.lN. lok ANSULSYSTEM YES l� NO FIRE DRILL SWITCH ::E�A -.-.T DATE (INSTALLED) Oct-15 DEVICES TESTEDJON BATTERIES1 LOAD TESTED I— YES NO ALL ZONES r YES l— 0% i- GOOD NOTIFICATION DEVICES F YES l N F MARGINAL ANNUNCIATOR F YES Fv NO I— NA IV FAILED MASTER BOX F YES F NO r NA REPLACED Fv- YES F q0 DIGITAL COMMUNICATOR F YES NO l— NA MASTER BOX Gamewell F- TESTED F- YES T N MASTER BOX(Electronic) F MasterBox# TESTED F- YES I, N SUPERVISED DISCONNECT (Of Electronic Master r Box) To Fire Dept YES I NO Trouble FAOP I— YES NO SIGNAL TRANSMITTED To FIRE HEADQUARTERS F- YES W N DIGITAL DIALER Iv— YES F NO AC t# 04-1701 TESTED W YES F N DIGITAL ALARM TRANSMISSION RECEIVED BY: Home securi BB Alarm ANNUNCIATOR SUPERVISION OK Iv- YE � NO F NA MASTER BOX SUPERVISION OIL F YES I— NO P NA ZONE SUPERVISION OK NiYES l— N HORN CIRCUITS SUPERVISION OK I YES N TROUBLE SIGNAL.&LIGHTS SUPERVISION OK I `DES � NO A/C CIRCUIT BREAKER A-IDENTIFIED I— YES I� N Q-LOCK IN PLACE E l— NO �RR1NK ER-"- NES' SPRINKLER SYSTEM INSTALLED IN BUILDING - YES Fv N SPRINKLER SYSTEM CONNECTED TO FIRE ALARM SYSTEM I— YES I— N NUMBER OF SPRINKLER ZONES ZONES CHECKED FOR OPERATION " YES NO SPRINKLER TEST REPORT ATTACHED " YES L- NO COMPANY RESPONSIBLE FOR TEST REPORT [77 f E E11 S" R REPAIRS ::::` .................. Smoke detector in stairwell outside unit A w replaced. o itivity r off. .......................................Unable to get into locksmith's unit. It was closed. TECH LI # 2 99-D James Kukene COMPANY LID# - TEST CONDUCTED BY(TECHNICIAN) DATE f / o 0 l: PRICE f. i