HomeMy WebLinkAboutSeptic Construction Notes - Consultant Review - 469 BOSTON STREET 9/1/2020 • SFTTLEDI
•
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 469 Boston Street MAP: 107.D LOT: 49
INSTALLER: Ralph Simard — Simard Construction 508-958-2002
DESIGNER: James Kavanaugh — Environmental Consultant 978-664-2925
PLAN DATE: 5/3/2019, rev 6/3/2019, rev 7/3/2019
BOH APPROVAL DATE ON PLAN: 9/23/2019
INSPECTIONS
TANK INSPECTION: 11/12/2019 S. Casey
DATE OF BED BOTTOM INSPECTION: 11/14/2019 S. Casey
DATE OF FINAL CONSTRUCTION INSPECTION: 11/21/19
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
11/21/19 — Existing septic tank and pump chamber re-used. Confirmed
manholes to finished grade and effluent filter in outlet of septic tank, manhole to
grade on pump chamber. Confirmed alarm functionality. No water in tank to
confirm pump functionality
DISTRIBUTION-BOX
❑ Installed on stable stone base
® H-20 D-Box
® Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
® Schedule 40 PVC Pipe
d
Comments:
11/21/19 — Flow was not evenly distributed to distribution box outlet pipes, no
hydraulic cement around pipe penetrations
SOIL ABSORPTION SYSTEM (General)
® Bottom of SAS excavated down to C soil layer,
as provided on plan
® Size of SAS excavated as per plan
® Title 5 sand installed, if specified on plan
S.Casey inspected at Bottom of Bed 11/14/2019
® 40 Mil HDPE barrier installed
® Laterals installed and ends connected to
header (and vented if impervious material
above)
® Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete / timber/ block)
❑ Final cover as per plan
Comments:
11/21/19 — Confirmed presence of former impervious barrier at approximate
elevation indicated on design plan
FINAL GRADE
❑ Loamed Wt\\
❑ Seeded
❑ Cover per plan
�L)
Comments:
DOCUMENTS NEEDED
Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
As-Built Plan
BM = 103.58
HR = 1.43
H I = 105.01
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Distribution Box IN 4.95 99.73 99.67
Distribution Box OUT 5.13 99.55 99.50
Lateral 1 Beg 5.23 99.45 99.41
Lateral 1 End 5.46 99.22 99.18
Lateral 2 Beg 5.23 99.45 99.41
Lateral 2 End 5.46 99.22 99.18
Lateral 3 Beg 5.23 99.45 99.41
Lateral 3 End 5.46 99.22 99.18
Barrier, Top 5.84 99.17 99.56
Bottom of Bed 6.40 98.61 98.68
11/22/2019 Town of North Andover Mail-Final Construction Inspection-469 Boston Street
NORTH ANDOVER
Massachusetts Toni Wolfenden <twolfenden@northandoverma.gov>
Final Construction Inspection - 469 Boston Street
1 message
Dan Ottenheimer<dano@millriverconsulting.com> Fri, Nov 22, 2019 at 9:21 AM
To: Brian LaGrasse <blagrasse@northandoverma.gov>, Stephen Casey<scasey@northandoverma.gov>, Toni Wolfenden
<tolfenden@northandoverma.gov>
Cc: Sandra Lezcano <sandral@millriverconsulting.com>
Brian, Steve, Toni -
Attached please find the findings of our inspection at 469 Boston Street.
There were some unresolved issues which will need to be re-examined. You can likely do so at the final grade inspection,
or we can do so if you'd like. They are noted on the report and also explained below:
• The distribution box did not have hydraulic cement at the pipe penetrations
• There was not enough water in the pump chamber to confirm the operation of the pump
• There was not even flow coming out of the distribution box to the three arms of the leach field. The branch closest to
the dwelling was not receiving much of any flow. They reported they were going to either adjust the pipes or d-box, or
else put in leveling devised inside the pipe. I asked them if they did the latter to check to make sure they have not
restricted the flow to the field when the pump turned on
The contractor was going to leave the distribution box area uncovered so these items can be reviewed at the final grade
inspection.
Any questions, do let me know.
Dan
Daniel Ottenheimer, PE
President
https://mail.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permthid=thread-f%3A1650912138982392866&simpl=msg-f%3A165091213898... 1/2
11/22/2019 Town of North Andover Mail-Final Construction Inspection-469 Boston Street
MILL RIVER CONSULTING
CArAh r Solutinns for land Developnnc-tit
6 Sargent Street
Gloucester, MA 01930-2719
Phone: 978-282-0014 ext.802
www.millriverconsulting.com
Member: New England Water Environment Association, Yankee Onsite Wastewater Association, Massachusetts
Environmental Health Association
c Construction Notes -469 Boston Street.doc
369K
https://mai l.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permth id=th read-f%3Al 650912138982392866&sim pl=msg-f%3A165091213898... 2/2
To whom it may concern,
I, Matt Quinlan, Owner of 469 Boston St. have requested that Simard Construction loom and
seed in the spring due to time of year.
Thank you