HomeMy WebLinkAboutFire Alarm Inspection Report - Inspection - 11/12/2019 V' ow " Progress Tyngsboro,MA 011879 FIRE ALARM INSPECTION REPORT Property Name Name. _ i t e: Address: Inspection TIC' Representative,, License N fin' Monitoring y Approving Agency Contact: Contact.- �(-!id,14 Telephone: Tellephone.1- Type T ransmissionService McCulloh Weekly Multiplex Monthly Digital quarterly Reverse Priority Semiannually Annually Other Seci ) Dialer Other(Specify)-, Control rMainufacturer: J ] 'N�42 L2Model#: 0 Circuit Styles: 14 Numberof Circuits: Software Rey, Last Date System Had Any Service Performance: Last Date that Any Software r Configuration,was Revised: Quantity Circuit Sale Manual Fire Alarm Pills I n Detectors 17 Photo,Detectors Duct Detectors Heat(Detectors Waterfliow Switches Supervisory Switches Other Sri ' -, Other(Specify).. Other(Specify) Other(Specify): Afar rin feature'Is,disabled enabled Paige � r ALARM NOTIFICATION APPLIANCESAND CIRCUIT INFORMATION Quantity Circuit Style .,.� Bells Morns/Strobes Chines Strobes Spars - Other(Specify):Booster—Fire Lit No.ofaarr notification appliance circuits: � Are Circuits monitored d for integrity? Yes No SUPERVISORY I f1 L-I ITIATIN DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style uildingTemp. Site water Temp. Site water Level Fire Pump Power Fire Pump Running Fire Pump or Pump ControllerTrouble Fire Pump Punning Generator in Auto Position Generator or ControllerTroubl Switch Transfer Generator Engine Punning Other(Specify : SIGNALING LINE CIRCUITS Quantity and style of signaling line circuits connect to system Quantity Style(s) SYSTEM POWER SUPPLIES Primary(Main): Nominal Voltage� �� Amps Q-cD overcurrent Protection: Type. . . 14 eX Amps V-0 Location of Primary Supply Pain iboard : 4 (Q<leilc Disconnecting Mears Location: Secondary Standby: V, Storar ge Battery: Calculated capacity to operate system,in hours: 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: TYPE BITTY r +Cell Lead-lucid Nickel-Cadmium Other(Specify) Sealed Lead-Acid Emergency or standby system used as a backup to primary poorer supply, instead of using } a secondary power supply Emergency system described in iFPA 70,Article Too f Legally required standby described ire NFPA 70,Article 701 Optional standby system described in NFPA 7 ,Article 7 ,which also meets the performance requirements of Article Too or 701. r: r. n Page 2 of 4 F ' PRIOR TO ANY TESTING NOTIFICATIONS ARE MADE Yes No Who T1 2e Monitoring Entity Building Occupants ---- __ Building Management Other(Specify) AHJ Notified of Any Impairments SYSTEM TESTS AND INSPECTIONS TYPE Visual Functional Comments Control Unit Interface Equipment L e:�� Lamps/LEDS Fuses ..� Primary Power Supply l Trouble Signals Disconnect Switches Ground-Fault Monitoring - -- SECONDARY POWER TYPE Visual Functional o e:n s 11/0 Battery Condition Load Voltage Discharge Test - -------- hrgerTes _ Specific Gravity TRANSIENT SUPPRESSORS REMOTE ANNUNCIATORS NOTIFICATION APPLIANCES Audible - -- Visible Speakers Voice Clarity INITIATING AND SUPERVISORY DEVI E TESTS AND INSPECTIONS Measured Loc.&SIN Device Type Visual CSC Func Test Fact Setting Settings Pass Fail Comments: Page 3 of f k EMERGENCY CY OI1fIMU I ATI S EQUIPMENT Visual Functional Comments Phone Set Phone-Jacks Tone Generator(s) Call-in Signal System Performance Device INTERFACE EQUIPMENT Visual Operations Operation (Specify) (Specify) (Specify) SPECIAL HAZARD SYSTEMS (Specify) (Specify) (Specify) Special Procedures: Comments: SUPERVISING STATION MONITORING Yes No Time Comments Alarm Signal 0 0 Alarm Restoration Trouble Signal Supervisory Signal Supervisory Restoration NOTIFICATIONS THAT TESTING IS COMPLETE Who Time Building Management R�r k -0 Monitoring Agency � Building Occupants Other(Specify) The Following did not operate correctly: } Y stem restored to normal operation: Date: � Time: f THIS TESTING WAS PREFORMED N ACCORDANCE WITH APPLICABLE NFPA STANDARDS, fV ............. Date: TIr11e; Name of Inspector: Signature: Name of Owner or Representative: Date. Time: Signature: Page 4 of i B iidin /Site: .� inspection Date: �1 1�a v7 D:Smoke Detector DD:Duct Detector BD:Beam Detector H:Deer Holder PS: Pull Station A :Annunciator P RS: Power supply DA:Damper Activation RESULTS Device Location Zone Address## bass Fail j t EL R Lt.' 12 � a .4 t b1L, , 'If L V 1VjCL'1.VAr ......... FE f,> 18 , .... ..Q D 0.)2 Rto 76) e it i& IN FL FLW .......... Ala kd F All r ---------------- .. . ....... ...... ZGI- CIV I Deficiencies: Customer's Signature: Inspector's Signatures: Page