Loading...
HomeMy WebLinkAboutDEP Approved Inspection & O&M Form - Title 5 - Title V Inspection Report - 43 MILL ROAD 12/11/2020 Massachusetts Department of Environmental Protection Bureau of Resource Protection - Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems A. Installation Important:when Philip Wilson RECE�VE� filling out forms -- - -- —"— -- Owner `t0 on the computer, 43 Mill Rd DEC 1 1 use only the tab key to move your Facility Street Address ,WR A A cursor-do not N Andover 01845 TpWN %TN pEpPAW use the return -- key. City Zip Mailing address of owner, if different: Street Address/PO Box: rewn City State Zip Telephone Number B. Authorized Service Provider Sewer Works O&M Firm 26 Hillside Ave Street Address Westford Ma 01886 City State Zip (978)692-4410 ex_t._ - Telephone Number David Chandler Certified Operator Name Certification Number C. Facility/System Information 24428 0.5 DEP ID Manufacturer ID Model Number 4/2005 4/2005 Installation Date Start of Operation Approval Type: ® General ❑ Provisional ❑ Piloting ❑ Remedial Seasonal Residence-used less than 6 mo./year: ❑ Yes ❑ No D. Operating Information 11/5/2020 9/13/2019 Inspection Date Previous Inspection Date 18" aerobic zone, Sludge Depth(to be checked yearly) Pumping Recommended ® Yes El NO t5aiom.doc•rev.04-11-13 Page 1 of 3 Massachusetts Department of Environmental Protection 'l Bureau of Resource Protection - Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems E. Field Testing Field Inspection: Color: ❑ gray ❑ brown ® clear ❑ turbid ❑ Other(specify): Odor: ❑ musty ® earthy ❑ moldy ❑ offensive ❑ turbid Effluent Solids: ® no ❑ some 8.04 SU 3 _ _ 2.2 NTU pH 6 to 9 DO .0 mg/I 2 or greater Turbidity 40 or less Should a Remedial or General Use system fail the Field Testing, effluent samples shall be collected per Standard Methods and analyzed for BOD and TSS. F. Sampling Information Samples Taken: ❑ Influent ® Effluent Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use nitrogen reducing systems: gpd Parameters sampled: ❑ pH ❑ BOD ❑ CBOD ❑ TSS ❑ TN ❑ Other(list below) Other 1 Other 2 Other 3 G. Inspection and Maintenance Description of any maintenance performed since previous inspection &during this inspection: blower amps 3.3, cleaned filter Notes and Comments: t5aiom.doc•rev.04-11-13 Page 2 of 3 LlMassachusetts Department of Environmental Protection Bureau of Resource Protection - Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A i Treatment and Disposal Systems H. Certification I certify: I have inspected the sewage treatment and disposal system at the address above, have conducted the required Field Testing and/or sample collection in accordance with Standard Methods, have completed this report and the attached technology operation and maintenance checklist, and the information reported is true, accurate, and complete as of the time of the inspection. I am a M ac setts certified operator in accordance with 257 CMR 2.00. (/w 11/05/2020 Operator Signature Date System owner must submit this report, technology O&M checklist, and any required sampling results to the local board of health as follows for each inspection performed: Remedial Use— by January 31"of each year for the previous calendar year Piloting Use-within 45 days of inspection date Provisional Use—by March 31th of each year for the previous 12 months General Use—by September 30th of each year for the previous 12 months Send to: Department of Environmental Protection Attention: Title 5 Program One Winter Street, 5t Floor Boston, MA 02108 t5aiom.doc•rev.04-11-13 Page 3 of 3 Nashoba Analytical, LLC Tel:978-391-4428 Fax:978-3914643 LabNumber. 221504 31A Willow Road,Ayer MA 01432 Website:http:/,www.NashobaAnalytical.com Use this number with all correspondence Client: Sewer Works ReportDate: 11/6/2020 26 Hillside Ave. Westford, MA 01886 Certificate of Analysis 43 Mill Road, N. Andover, MA Parameter Method Result MRL Date of Analysis Analyst - Pump Chamber Sampled. 11/5/2020 10:00.00 AM by D Chandler Turbidity, NTU EPA 180.1 2.2 0.1 11/5/2020 M-MA1118 MRL=Minimum Reporting Level,ND=None Detected(<MRL) r. Analysis performed according to 31 OCMR42.00 `r Massachusetts Certified David L.Knowlton Laboratory#M-MA1118 Laboratory Director Page 1 of 1