HomeMy WebLinkAboutDWC Full Repair - Correspondence - 997 DALE STREET 9/27/2019 9/30/2019 Town of North Andover Mail-Final Construction Inspection,997 Dale Street
NORTH ANDOVER
Massachusetts Toni Wolfenden <twolfenden@northandoverma.gov>
Final Construction Inspection, 997 Dale Street
1 message
Dan Ottenheimer<dano@millriverconsulting.com> Fri, Sep 27, 2019 at 12:37 PM
To: Brian LaGrasse <blagrasse@northandoverma.gov>, Stephen Casey<scasey@northandoverma.gov>, Toni Wolfenden
<twolfenden@northandoverma.gov>
Cc: Sandra Lezcano <sandral@millriverconsulting.com>
Brian, Stephen, Toni -
Attached please find our notes for the construction inspection which occurred at 997 Dale Street.
As indicated in previous communication, several issues were identified which are indicated in the attached report.
If you have any questions or need further assistance please do let me know.
I will be out of the office on Monday and Tuesday of next, by the way, in case that matters as it relates to this particular
site.
Dan
Daniel Ottenheimer, PE
President
�CIINIIIIIlIliiI
4 MILL RIVER CONSULTING
Cltativr S011160M krr i.atui DCVC10p171rnt
6 Sargent Street
Gloucester, MA 01930-2719
https://mail.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permthid=thread-f%3A1645847257723698903&simpl=msg-f%3Al64584725772... 1/2
9/30/2919 Town of North Andover Mail-Final Construction Inspection,997 Dale Street
Phone: 978-282-0014 ext.802
www.millriverconsulting.com
Member: New England Water Environment Association, Yankee Onsite Wastewater Association, Massachusetts
Environmental Health Association
Construction Notes -997 Dale Street.cloc
380K
https:Hmail.google.com/mail/u/0?ik=a0c6f4e4cf&view=pt&search=all&permthid=thread-f%3Al 645847257723698903&simpl=msg-f%3A 164584725772... 2/2
9/26/2019 Town of North Andover Mail-997 Dale Street issues to look out for
NORTH ANDOVER
Massachusetts Toni Wolfenden <twolfenden@northandoverma.gov>
997 Dale Street issues to look out for
2 messages
Dan Ottenheimer<dano@millriverconsulting.com> Thu, Sep 26, 2019 at 6:47 AM
To: Brian LaGrasse <blagrasse@northandoverma.gov>, Stephen Casey<scasey@northandoverma.gov>, Toni Wolfenden
<twolfenden@northandoverma.gov>
I assume Peter Breen is going to call you for a re-inspection at this site. I can do so if the Town wishes, but if you do it
here are some things to note:
Attached are photos of the three main remaining open items:
• The hole that was cut into the concrete was filled with rocks and other detritus. It did not at all appear like it was
watertight. He was going to remove the junk he put in there and attempt to make the pipe penetration watertight and then
test and examine it before calling you. You should make sure the water level is up at the outlet and that he has exposed
around the outside of the pipe and that it is dry underneath
• The pump shown is not the one on the plan. It should have been a blue pump made b Barnes. I am told he is going
to switch it to the pump that was called for. That needs to be checked
• The floats he had set almost on the floor of the pump tank. They need to be raised up and set to the setting
indicated on the plan
In addition, the D-box needs to be confirmed to be H-20, and risers to grade need to be over the effluent filter and pump
I will get you a formal write-up but I wanted to highlight these issues so they would not get lost in the inspection report.
Dan
Daniel Ottenheimer, PE
President
MILL RIVER CONSULTING
C 1X!ativr 5olutintts JOr laud 1)eV 0013171Mt
6 Sargent Street
Gloucester, MA 01930-2719
https://mail.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permthid=thread-f%3Al645734613884381438&simpl=msg-f%3A164573461388... 1/3
9/26/2019 - Town of North Andover Mail-997 Dale Street issues to look out for
Phone: 978-282-0014 ext.802
www.millriverconsulting.com
Member: New England Water Environment Association, Yankee Onsite Wastewater Association, Massachusetts
Environmental Health Association
2 attachments
20190924_162937.jpg
318K
e
20190924_162828.jpg
207K
Toni Wolfenden <tolfenden@northandoverma.gov> Thu, Sep 26, 2019 at 8:40 AM
To: Dan Ottenheimer<dano@millriverconsulting.com>
Cc: Brian LaGrasse <blagrasse@northandoverma.gov>, Stephen Casey<scasey@northandoverma.gov>
Thank you for the update.
Toni K. Wolfenden
Health Department Assistant
978-688-9540
L,p;cid:image002.jpg@O1 CD02A1.85A49B40
[Quoted text hidden]
image001.jpg
4K
https://mai l.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=a II&permthid=th read-f°/o3A l 645734613884381438&simpl=msg-f%3A164573461388... 2/3
g2ie2Z@g ! 2019094162937&g
. . >, .
^\x .
� . .
� ..
%\�\
\ � ±
kps:/k:mm.co m_Amako FMt_DRV_mc STpvhe«+projec mml&_amea+ol �d
9/26/2019 p 20190924_162828.jpg
� x
R
S
https:Hmail.google.com/mail/u/0/#inbox/FMfcgxwDrRVzwrwCSQprDTpDshBDstlg?projector-1&messagePartld=0.2 1/1
9/25/2019 Town of North Andover Mail-997 Dale Street
-NORTH ANDOVER
Massachusetts Toni Wolfenden <twolfenden@northandoverma.gov>
997 Dale Street
1 message
Dan Ottenheimer<dano@millriverconsulting.com> Wed, Sep 25, 2019 at 9:00 AM
To: Brian LaGrasse <blagrasse@northandoverma.gov>, Stephen Casey <scasey@northandoverma.gov>, Toni Wolfenden
<tolfenden@northandoverma.gov>
I completed the inspection yesterday for the project that Peter Breen built.
There were a number of issues that were wrong or otherwise need tending to. Among them were: wrong pump, floats
might not have been set correctly, d-box might have not been H-20, pipe exiting the septic tank might not be watertight,
and possibly the wrong benchmark was used.
In this instance I have tasked the designer to get back involved to examine things and report back as to their findings.
The situation is still open and hopefully being resolved, but I did want you to at least know about it in case something
comes your way.
At the very least, I know they will be contacting you at some point to come make sure the septic tank outlet pipe
penetration is watertight.
Dan
Daniel Ottenheimer, PE
President
A a,
�h[ LL RIVER CONSULTING
Creative Sotutirms for Land Development
https://mail.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permthid=thread-f%3A1645652376687988748&simpl=msg-f%o3A164565237668... 1/2
9/25/2019 Town of North Andover Mail-997 Dale Street
.6 urgent Street
r Gloucester, MA 01930-2719
Phone: 978-282-0014 ext.802
www.millriverconsulting.com
Member: New England Water Environment Association, Yankee Onsite Wastewater Association, Massachusetts
Environmental Health Association
https://mai l.goog le.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permthid=th read-f%3A1645652376687988748&simpl=msg-f%3Al 64565237668... 2/2
8/7/2019 Town of North Andover Mail-Revised plan review-997 Dale Street
NORTH ANDOVER
Massachusetts Toni Wolfenden <twolfenden@northandoverma.gov>
Revised plan review - 997 Dale Street
1 message
Dan Ottenheimer<dano@millriverconsulting.com> Wed, Aug 7, 2019 at 3:26 PM
To: Brian LaGrasse <blagrasse@northandoverma.gov>, Stephen Casey<scasey@northandoverma.gov>, Toni Wolfenden
<twolfenden@northandoverma.gov>
Cc: Sandra Lezcano <sandral@millriverconsulting.com>
We have completed our review of the revised plan for 997 Dale Street and find it meets the requirements in state and
local regulations. No variances or Local Upgrade Approvals are being requested.
Any questions, do let me know.
Dan
Daniel Ottenheimer, PE
President
`1FM L'L RIVER CONSULTING
Creative aotu iii)m for I xid 1'kve1oj)mt rt
6 Sargent Street
Gloucester, MA 01930-2719
Phone: 978-282-0014 ext.802
www.millriverconsulting.com
Member: New England Water Environment Association, Yankee Onsite Wastewater Association, Massachusetts
Environmental Health Association
https://mail.google.com/mail/u/0?ik=aOc6f4e4cf&view=pt&search=all&permthid=thread-f%3A1641237409381078742&simpl=msg-f%3A164123740938... 1/2
7/22/19
Job#: NAND-0079 W-10 & WILLIAMS
SPARAGES
ENGINEERS . PLANNERS �SURVEYORS
Brian Lagrasse, CEHT
Director of Public Health
North Andover Health Department
Community and Economic Development Division
Town Hall, 120 Main Street RECEIVED
North Andover, MA 01845
Re: 997 Dale Street(Map 104A, Lot 10)
TOWN OF NORTH ANUUVER
HEALTH DEPARTMENT
Dear Mr. Lagrasse,
Please see your comments below with notes regarding revisions to the proposed septic design plan at
997 Dale Street.
1. Indicate the names of the abutters from the most recent tax maps(NA 3.2)
Abutters have been added to the plan view on Sheet S-1.
2. Indicate the brand and model of proposed effluent filter and include copy of MassDEP
approval (NA 3.2)
The septic tank detail on Sheet S-2 already indicates the type of effluent filter to be used.A copy
of the Zabel A1800 series approval is included in this application.
3. Indicate building sewer pipe joints are to be watertight(310 CMR 15.222)
A note has been added in the system profile section on Sheet S-2 indicating the requirement for
building sewer pipe joints to be watertight.
4. Indicate building sewer is to be laid on a compact firm base and on a continuous grade in a
straight line(310 CMR 15.222)
A note has been added in the system profile section on Sheet S-2 indicating the requirement for
the building sewer to be laid on a compact firm base and on a continuous grade in a straight line.
5. Indicate or depict tees inside tank to extend 6"above the flow line(310 CMR 15.227)
A note has been added in addition to 6"arrowheads in the septic tank detail on Sheet S-2
indicating that tees inside the septic tank must extend 6"above the flow line.
189 North Main Street, Suite 101 • Middleton, MA 01949 • Tel: (978) 539-8088 • www.wsengineers.com
6. Indicate requirement for the tanks to be watertight(310 CMR 15.221)
A note has been added to the septic tank detail on Sheet S-2 indicating the requirement for the
septic tank to be watertight and a note has been added to the pump chamber detail on Sheet S-3
indicating the requirement for the pump chamber to be watertight.
7. Indicate piping exiting the distribution box are to be laid level for at least the first 2' and to be
at the same elevation as each other(310 CMR 15.232)
A note has been added to the system profile section on Sheet S-2 indicating the requirement for
piping exiting the distribution box to be laid level for at least the first 2'and to be at the same
elevation as each other.
8. Indicate the leach pipe orifice size to be 3/8"—5/8"(310 CMR 15.251)
A note has been added to the system profile section on Sheet S-2 indicating the requirement for
the leach pipe orifice size to be 3/8"-5/8".
9. Indicate the distribution box is to be watertight(310 CMR 15.221)
The current note with a leader to the distribution box on Sheet S-2 already indicated the
requirement for the distribution box to be watertight, however a note has also been added to the
distribution box detail on sheet S-3 indicating that requirement as well.
10. Depict the desired distribution box dimensions, indicate all outlets are to be at the same
elevation (310 CMR 15.232)
The desired distribution box dimensions are already depicted on Sheet S-3 in the distribution box
detail. The note added on the system profile on Sheet S-2 for#7 indicates the requirement for all
outlets to be at the some elevation.A note has been added to the distribution box detail on Sheet
S-3 indicating that the inlet tee must provide 1"between the bottom of the tee and the outlet
invert.
11. Indicate the high water alarm is to be located in the building and powered from a separate
circuit as the pump(310 CMR 15.231)
Note 27 has been added to sheet S-2 indicating the requirement for the high water alarm to be
located in the building and powered from a separate circuit as the pump.
12. Clarify the notation beneath the septic tank detail specifying a 2-compartment tank and the
image which depicts a 1-compartment tank
Notation has been revised in the septic tank detail on Sheet S-2 identifying the septic tank as 1-
compartment.
13. Label the pump tank image on Sheet 3
The pump chamber detail on Sheet S-3 has been labeled correctly.
14. Depict or notate a manhole cover to finished grade at the pump tank image on Sheet 3
A note has been added to the pump chamber detail on Sheet S-3 indicating the requirement for
the outlet manhole to be brought to finish grade.
If you have any other questions or concerns please let us know.
Thanks,
OP
ThorAerey,4R �
Williams&Sparages, LLC.