Loading...
HomeMy WebLinkAboutAs-Built Plan - As-Built Plan / Installation Certificate Form - 113 BRIDGES LANE 4/25/2005 E N/F KUROWSKI a 113 BRIDGES LANE ASSESSORS MAP 104D, LOT 115 0'°4g'�1,E \ 44,351 SQ. FT. O0. � SITE NwP 25'NO DISTURB ZONE eR��fS Ne �50'NO BUILD ZONE N/F CAMMARATA \ 100'BUFFER TONE N/F COLARUSSO \ TREE LINE � 0}4 \ \ LOCUS MAP NOT TO SCALE F \ wF \ \ This is to certify that New England Engineering Services Inc. has inspected the subsurface sewage disposal wF 'I system installed at 113 Bridges Lane, North Andover, MA. The system has been constructed in compliance with 310 CMR 15.00, the approved design plans dated 9/30/2004, \ and local requirements, except as noted herein. wF wF I / 40 MIL IMPERVIOUS BARRIER �Q DISTRIBUTION BOX \ 3' 1 TP2 / TPf/PTI I r' SCU.4O PVC INVERT ELEVATIONS FORCE MNN _ ACTUAL DESIGN FOUNDATION 100.86 100.12 BENCHMARK: NAIL IN 12"DIM TREE. '�, / TANK IN 100.55 99.92 ELEV.100.00 me(assud dome,). TANK OUT 100,18 99.67 ABORTED PUMP IN 100.15 99.62 TEST PIT `.!.-�"/ I a5' VENT PUMP OUT 100.11 99.37 \!� SEGMENTAL BLOCK D-BOX IN 104.73 104.72 INSPECTION RETAINING WALL D-BOX OUT 104.56 104.55 PORTS(111) 26.17' / 1000 GALLON PUMP __ PUMP CHAMBER A 104.4 104.45 0 _----- ,- _ 2 C ®o--"`�' �'` 8 104.44 104.45 DECK P RCn z1----"' \\ C 104.44 104.45 O �-)00'BUFFER ZONE D 104.44 104.45 "�--� -'- 1500 GALLON ` I 04.45 104.45 0 I SEPTIC TANK \`j`\ F 104.44 1D4.45 / Exlsimc EoeR T, G 104.44 10445 H 104.44 104.45 BEDROOM HOUSE 104.46 104.45 SILL ELEV 10"' J 104.45 104,45 K 104.44 104.45 L 104.44 104.45 GO M 104.44 104.45 N 104.44 104.45 W 0 104,44 104.45 W W E \ a, p P 104.43 104.45 ED ^ \ BOTTOM OF INFILTRATORS 103.90 103.91 Q C 50'NO C12 \ E BUILD BUILD ZONE R� <N G za SYSTEM TIES w / 3 TO TANK 27.8' 2 TO TANK 18.6' w \ 3 TO PUMP 39.8' z / 25'NO 2 TO PUMP 12.4' TREE LINE DISTURB ZONE 1 TO D-BOX 49.5' w WF \ 2 TO D-BOX 50.1' WE 1 TO A 45.8' 1 TO 9.0' 11 2 TO A 50.6' 2 TO 25.8' W \ 1 TO H 49.3' 1 TO P 20.4' U 4➢4 2 TO H 45.5' 2 TO P 8.0' RUE CTRIOAOL '°'''uT" E"ns O^& INSPECTION PORTS SERVICE '1"}C^ WF t N1nNl it } 1 TO Y 17.9: 1 TO Z 25.T _ D o01 +N "' 2 TO Y 30.0' 2 TO Z 1Z5 LVI No' " WF �� 1511n J 4 QQ�a�a� 20' 0 20' 40' 60 ___, .. w B�'OP@MED c PRESSURE \ w WATER SERVICE AS-BUILT SEP`1'IC SYSTEM 'ro 211Uz 113 BRIDGES LANE NORTH ANDOVER, MA, ASSESSORS MAP 104D, PARCEL 115 SCALE: 1" = 20' APRIL 22, 2005 L = 150.00' NEW ENGLAND ENGINEERING SERVICES, INC. R = 240.18' Ilk 60 BEECHWOOD DRIVE NORTH ANDOVER, MA 01845 LANE (978) 686-1768 I BRDGES LN PLAN # DRAWN CHECKED 937SAB-4-22-05 Dv: S.G.B. BY: T.K.H. & B.C.O. Jr.