Loading...
HomeMy WebLinkAboutSeptic Denial Letter - Correspondence - 328 CAMPBELL ROAD 7/26/2021 North Andover Health Department (ommunity and Economic Development Division July 26, 2021 Charles Wear III, P.E. Hancock Associates 185 Centre Street Danvers, MA 01923 Re: Subsurface Sewage Disposal System Plan for 328 Campbell Road (Map 106D, Lot 24) Dear Mr. Wear: The proposed wastewater system design plan for the above site dated March 9, 2015. Unfortunately,the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. 1. The proposed distance between the estimated seasonal high groundwater table and the bottom of the soil absorption system is proposed as 3.0' on some sections of the design plan and 3.5' on others and on the Application for Local Upgrade Approval. Clarify 2. Depict the water service line beyond the small section which is depicted and clarify if it is a private well or a public water supply connection 310 CMR 15.220) 3. All piping is required to be PVC schedule 40,which conflicts with some plan notes that specifies others (NA 3.2) 4. The full legal boundaries of the facility being served are not shown on the design plan. (310 CMR 15.220(4)(a)). 5. The lot area needs to be indicated (NA 3.2) 6. Distances from lot lines and structure to the soil absorption system need to be indicated (NA 3.2) 7. Indicate if the parcel is within the Lake Cochichewick watershed (NA 3.2) 8. As part of abandonment of the existing system indicate that the cesspool contents are to be pumped by a licensed septage hauler(310 CMR 15.354 and NA 3.2) 9. Compliance with the wetlands setback is not maintained (NA 3.9) 10. The building sewer is to be noted to be laid on a compact and firm base and in a continuous grade and in a straight line (310 CMR 15.222) Page 1 of 2 North Andover Health Department, Town Hall, 120 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542 11. The septic tank is to have the tees located under the manholes and on the center line (310 CMR 15.227) 12. The design plan specifies use of an effluent filter but does not indicate the brand and model, nor specify the required annual maintenance or cover to grade (310 CMR 15.227 and NA 3.2) 13. It does not appear 9" of cover is specified over the tank. Indicate a proposed spot finished grade (310 CMR 15.228) 14. Specify the orifice size for the leaching pipes as 3/8"-5/8" diameter(310 CMR 15.251) 15. Clarify the cleanout specified in the Construction Key Notes as it is not apparent on the site plan 16. The Site Plan does not have a scale associated with it 17. The barrier should be depicted on the Flow Profile 18. Provide a construction detail of the concrete slab that is begin requested beneath the septic tank 19. Clarify Note 11 below the septic tank detail regarding the water tightness specification which is to be achieved as it does not reference a typical standard used in North Andover Although not a reason for disapproval, you may wish to consider the following: A. Groundwater elevation might be lower than what is used as the basis for your calculations B. The Construction Key Notes do not appear to be in the correct order. To avoid confusion during the installation process please review and adjust as might be needed C. It is possible the B soil does not need to be removed as indicated on the design plan D. The location of the percolation test was not depicted on the site plan Please feel free to contact the office or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely, irian�JLaGrasse, CEHT Director of Public Health cc: Owner File Page 2 of 2 North Andover Health Department, Town Hall, 120 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542