Fire Alarm System Inspection - Inspection - 84 MAIN STREET 7/1/2020
IMPACT FIRE SERVICES, LLC 26 HAMPSHIRE DRIVE HUDSON NH 03051 6 IMPACT 0 : 603.293.7531 F: 603.589.2051 FIRE WWW.GETFIREPROTECTION.COM FIRE ALARM SYSTEM INSPECTION MASTER ELECTRICIAN#: Inspected to the state adopted version of NFPA 72 MA-20423A, NH- 13117 M WORK ORDER M 19109030 DATE:07/01/2020 10:30am EDT CUSTOMER ID: BILL TO: SHIP TO: 82-88 MAIN ST 82-88 MAIN ST 82-88 MAIN ST 82-88 MAIN ST NORTH ANDOVER MA 01845 NORTH ANDOVER MA 01845 Phone:(617)438-0382 Contact:BILL ENDICOTT Email: William.endicott@gmail.com Phone: (617)438-0382 ® ANNUAL ❑ SEMI ANNUAL ❑ QUARTERLY ❑ SENSITIVITY ARRIVAL TIME:11:fl0 DEPARTURE TIME:12:30 PASS FAIL A. PANEL CONFIGURATION:Silent knight 5208 DETECTION CLASS: CLASS A: ❑ CLASS B: ❑■ SIGNAL CIRCUIT CLASS: CLASS A: ❑ CLASS B: A. ❑ ❑ PANEL LOCATION:Basement BATTERIES: VOLTAGE NO LOAD: 12v 7 ah 2012 B. QUANTITY:2 VOLTAGE LOAD: B. ❑ ❑ C. ANNUNCIATOR TYPE:Silent knight C. ✓ REMOTE PANEL TYPE: I ❑ D. TYPE:Starlink communicator 1 12v 7ah battery 2020 © ❑ TYPE; D. TYPE: ❑ ❑ E. PANEL GROUND: TERM: TO: READ: E. ❑ ❑ F. TYPE OF REMOTE ❑ MASTER BOX# ❑ RADIO MASTER BOX# F. ❑ ❑COMMUNICATION ® DIGITAL COMMUNICATOR: ❑ OTHER: G OFF LINE TIME; REPORTS TO:Rapid response G. ❑ ❑ ON LINE TIME: REPORTS TO: DUCT SINGLE PULLS R OF R FIXED SMOKES DETECTORS STATION DETECOT'ORS SMOKE EST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL TEST FAIL QTY 6 1 0 0 0 0 10 1 0 0 0 0 1 0 0 MINI MINI HORN Horn/Strobe Speakerlstrobe Visual Only Audible Only Outside STROBE Beacon TEST FAIL TEST FAIL TEST FAIL TEST FAIL TESfj FAIL TEST I FAIL TEST FAIL QTY 0 0 0 0 7 0 0 0 0 0 0 0 1 0 Page of IMPACT FIRE SERVICES, LLC 26 HAMPSHIRE DRIVE IMPACT HUbSON NH 03051 O : 603.293.7531 FIRE F : 602051 WWW.GETFIREPROTECTION.TION.COM FIRE ALARM SYSTEM INSPECTION MASTER ELECTRICIAN#: Inspected to the state adopted version ofNFPA 72 MA-20423A; NH- 13117 M WORK ORDER #: 19109030 DATE: 07/01/2020 10:30am EDT CUSTOMER ID: H. Explanation of Failed Devices: Panel batteries fail due to age installed in 2012. Panel falls due to illegal penetration of wiring with no grommet or connector. 120v power wire not secured needs to be secured all the way to the power panel with staples per national electric code. Smoke detector broken in the realtor office and failed to function. Pull station and horn strobe in realtor office fail due to both devices painted which is illegal per NFPA along with pull staton failed to operate. Panel in trouble on arrival and departure zone 4 this needs to be trouble shot in order to clear the panel. Smoke detector needs to be added above FACP Per NFPA 1. The inspector suggests that following necessary improvements. However, these suggestions are not the result of an engineering survey. These are recommendations based on current code. None at this time J. Adjustments or corrections made: None at this time K. Inspection and suggested improvements were discussed with the undersigned Owner or Owner's Representative. ❑ Yes ❑ No 711/2020 THIS IS NOT AN INVOICE CUSTOMER'S SIGNATURE DATE QTY PART#_ DESCRIPTION PRICE AMOUNT ,5poKe io pill On aepariblre CUSTOMER'S PRINTED NAME 7/1/2020 TECHNICIAN SIGNATURE DATE Michael St.Aubin,Joel Guerrero 100021ir TECHNICIAN PRINTED NAME LICENSE# ❑ BILLING ADDRESS CONFIRMED Page____of ' IMPACT FIRE SERVICES, LLC 26 HAMPSHIRE DRIVE HUDSON NH 03051 IM13ACT O :603.293,7531 F : 603.589,2061 ADDITIONAL NION COMMENTS WWW.GETFIREPROTECTION.COM FIRE INFOIINSP MASTER ELECTRICIAN#: DEVICE INSPECTION REPORT MA-20423A; NH- 13117 M Page of WORK ORDER#: 19109030 DATE: 07101/2020 10:30am EDT CUSTOMER ID: DEVICE MODEL LOCATION ZONE NOTES/COMMENTS:��� TYPE Smoke Basement Z9 ❑ smoke Basement Z9 ❑ ❑ pull Art school Z3 ❑✓ ❑ smoke Art school Z3 ❑ pull Realtor office Failed to operate/painted ❑ ❑✓ smoke Realtor office Failed to operate/broken ❑ Q Pull 1st floor Front Right side apartment stair Z6 ❑✓ ❑ Smoke 2nd floor right side apartment stair Z6 Q ❑ pull 1sl floor front left apartment stair Z5 ❑ ❑ smoke 1st floor front left apartment stair Z5 ❑ ❑ pull Left rear top of basement stair Z3 ❑ ❑ smoke Left rear top of basement stair Z3 ❑ ❑ smoke Left second floor rear Z5 ❑✓ ❑ Pull Right side first floor rear stairs Z4 ❑✓ ❑ Smoke Right side first floor rear stair Z4 ❑✓ ❑ smoke 2nd floor right rear stair Z6 ❑✓ ❑ End test ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ BILLING ADDRESS CONFIRMED CUSTOMER'S SIGNATURE-DATE TECHNICIAN'S SIGNATURE-DATE CUSTOMER'S PRINTED NAME Report of Inspection/Test Annual NFPA 25 1 M Fi.A C',PF[RE 26 Hampshire DR,Hudson,NH (603)293-7531 2020-07-17 Conducted by: Dennis Chase 261 BrooUs ST,Worcester,MA Property (508)852-7227 82-89 MAIN ST Impact Fire Services- Hudson 44 Garden ST,Suite 1,Danvers,MA 4653082 (978)304-1506 Builcling#: 15254065 82-88 MAIN ST NORTH ANDOVER MA 01845 BILL ENDICOTT 617-438-0382 Inspection Ref* 19140884 Report of Inspection/Test General Questions OWNER SECTION Is the building occupied? Yes Has the occupancy classification,hazard of contents, Yes and/or storage method remained the same since the last inspection? Are all fire protection systems in service? Yes Has the system remained in service without Yes modification since the last inspection? Was the system free of actuations of devices or alarms Yes since the last inspection? FIRE DEPARTMENT CONNECTION Has the Interior of the FDC been inspected for Yes Is the visible piping supplying the FDC undamaged? Yes obstructions? If locking caps/plugs are in place,has an internal Yes Is the FDC plainly visible and easily accessible? Yes inspections been conducted? Is the FDC easily accessible? Yes Are the FDC swivels and couplings not damaged? Yes Are the FDC caps and plugs in place and undamaged? Yes Are the FDC gaskets in place? Yes is the FDC check valve free of leaks? Yes Is the clapper and automatic drain valve in place and Yes properly operating? Is the FDC identification sign(s)in place? Yes SPRINKLER HEADS Are there the proper number and type of spare Yes Are visible sprinklers in the proper position:upright, Yes sprinklers with a list in place? pendent,sidewall? Are visible sprinklers free of corrosion and physical Yes is there proper clearance below the sprinklers? Yes damage? Are visible sprinklers free of foreign materials including Yes Is there liquid in all visible glass bulb sprinklers? Yes foreign paint? Are there spare sprinklers and a sprinkler wrench? Yes Is the information sign attached and legible? Yes Are all the sprinklers dated 1920 or later? Yes Fast response sprinklers 20 or more years old replaced N/A or successfully sample tested within last 10 years? Standard response sprinklers 50 or more years old N/A Standard response sprinklers 75 or more years old N/A replaced or successfully sample tested within last 10 replaced or successfully sample tested within last 5 years? years? Dry-type sprinklers replaced or successfully sample N/A Have sprinklers subject to harsh environments been N/A tested within last 10 years? replaced or successfully sample tested in the last 5 years? PIPES Are the visible pipe and fittings In good condition with Yes Do visible pipe and fittings have no mechanical damage Yes no external corrosion? 1,orleaks? Copyright 2020 Inspect Point Page 1 of 8 Report of inspection/Test IMPACT F`IRE Annual NFPA 25 26 Hampshire DR,Hudson,NH (603)293-7531 2020-07-17 Conducted by: Dennis Chase 261 Brooks ST,Worcester,MA Property (508)852-7227 82-88 MAIN ST Impact Fire Services-Hudson 44 Garden ST,Suite 1,Danvers,MA 4653082 (978)304-1506 Building#: 15254065 82-88 MAIN ST NORTH ANDOVER MA 01845 BILL ENDICOTT 617-438-0382 Inspection Ref#: 19140884 Does visible pipe have no external loads? Yes Are visible pipe hangers and seismic braces not Yes damaged or loose? Is the pipe through freezers free if any Ice blockage? N/A Has an internal investigation of the pipe been No performed in the last 5 years?(If no,conduct investigation) CONTROL VALVE AREA Are the control valves with electrical supervision in N/A Are the control valves with electrical supervision locked N/A correct(open or closed)position? or is supervision in place? Are the control valves with electrical supervision N/A Are the control valves with electrical supervision free NIA accessible? from any leaks? Are the control valves with electrical supervision have N/A Are the control valves with electrical supervision N/A the appropriate wrenches? properly identified? Are the control valves supervised with seals in correct N/A Are the control valves supervised with seals locked or is N/A (open or closed)position? supervision in place? Are the control valves supervised with seals accessible? N/A Are the control valves supervised with seals free from N/A leaks? Are the control valves supervised with seals have N/A Are the control valves supervised with seals properly N/A appropriate wrenches? identified? Are the control valves with locks in correct(open or N/A Are the control valves with locks locked or Is supervision N/A closed)position? in place? Are the control valves with locks accessible? N/A Are the control valves with locks free from any leaks? N/A Are the control valves with locks have the appropriate N/A Are the control valves with locks properly Identified? N/A wrenches? VALVE AREA Are the gauges on system showing normal water supply Yes Are all check valves Internally inspected,operating Yes pressure? properly,and are in good condition? Are the gauges on system operable and in good working No Is the hydraulic name plate(calculated systems) No condition? attached securely to the riser and legible? Are Pressure reducing valves(sprinkler system)in open N/A Are Pressure reducing valves(sprinkler system)with N/A position and not leaking? downstream pressure per the design? Are Pressure reducing valves in good condition including N/A Have the mechanical waterflow alarm devices passed N/A no handwheels broken? tests by opening inspector's test:connection/bypass connection with alarms actuating and flow observed? Do valve supervisory switches indicate movement? N/A The electrical waterflow alarm devices passed test by N/A opening inspector's test connection/bypass connection with alarms actuating and flow observed? Have post indicating valves been opened until spring or NIA All control valves operated through full range and N/A torsion felt in the rod and then closed back 1/4 turn? returned to normal position? Have pressure reducing valves passed partial flow test? N/A BACKFLOW PREVENTERS Copyright 2020 Inspect Point Page 2 of 8 Report of Inspection/Test IMPAC 1' 'FIRE Annual NFPA 25 26 Hampshire DR,Hudson,NH (603)293-7531 2020-07-17 Conducted by: Dennis Chase 261 Brooks ST,Worcester,MA Property (508)852-7227 82-88 MAIN ST Impact Fire Services-Hudson 44 Garden ST,Suite 1,Danvers,MA 4653082 (978)304.1506 Building#: 15254065 82-88 MAIN ST NORTH ANDOVER MA 01845 BILL ENDICOTT 617-438-0382 Inspection Ref#: 19140884 Is relief port on RPZ device not discharging? N/A THave backfiow devices passed forward flow test? Yes ALARMS Is the alarm valve free from physical damage? N/A Is the trim/valves in correct(open or closed)position? N/A Is there no leakage in the retarding chamber or drains? N/A Are alarms and supervisory devices not damaged? Yes Do low temperature alarms look DO N/A MAINTENANCE If a sprinkler failed a sample test were all the sprinklers N/A If sprinklers have been replaced,were they proper Yes represented by that sample replaced? replacements? Were marine systems normally having fresh water N/A Was heat tape inspected per the manufacturer's N/A drained and refilled twice if raw water got into the instructions? system? If conditions were found that required flushing,was N/A Have adjusted,repaired,reconditioned,or replaced N/A flushing of the system conducted? components had proper tests/inspections performed? Was a drain test conducted after opening any closed Yes Operating stem of all OS&Y valves lubricated,completely N/A valve? closed and reopened? I Have sprinklers and spray nozzles protecting N/A commercial cooking equipment and ventilating systems been placed annually? Copyright 2020 Inspect Point Page 3 of 8 Report of Inspection/Test Annual NFPA 25 1KPA.C`.I` FIRE', 26 Hampshire DR,Hudson,NH (603)293-7531 2020-07-17 Conducted by: Dennis Chase 261 Brooks ST,Worcester,MA Property (508)852-7227 82-88 MAIN ST Impact Fire Services-Hudson 44 Garden ST,Suite 1,Danvers,MA 4653082 (978)304.1506 Building#: 15254065 82-88 MAIN ST NORTH ANDOVER MA 01845 BILL ENDICOTT 617-438-0382 Inspection Ref#: 19140884 Report of Inspection/Test for System - Wet system FIRE DEPARTMENT CONNECTION Has the FDC been hydrostatically tested as required No Date of the last FDC hydrostatic test? N/A every 5 years? ANTIFREEZE Can antifreeze type be correctly Identified? N/A Is the antifreeze listed? N/A Is expansion tank pressure reading equal to 90%of N/A Supply? MAIN DRAIN FLOW TESTS System Initial static Residual Static Seconds to Flow Are results Return to Observed? comparable Initial Static to previous test? Wet system 135 85 135 immediate Yes Yes VALVES ----------- Tam valve ope Easily Stems Flow per System Description Location Type Size Secured n I Accessible Signs Exercised Lubricated Pass Pass Wet system System side Basement Sall 2- Not Secured Yes Yes Yes Yes Yes Pass N/A Wet system City side Basement Ball 2.. Not Secured Yes Yes Yes Yes Yes Pass N/A Copyright 2020 Inspect Point Page 4 of 8