Loading...
HomeMy WebLinkAboutReport of Inspection/Test - Inspection - 4/30/2021 Report of Inspection/Test Annual NFPA 25 TlazdjL"_ FIRE PROTECTION 2021-04-30 Conducted by:Jim O'Sullivan CO.,tic AENAVNRNNANAENMENmmoomm Property Manchester#W481 1060 Osgood Street MA Lie#SJ-001 500 TIA001 1060 Osgood Street Hampshire Fire Protection Co.,LLC North Andover MA 8 North Wentworth Avenue David Sarnuels Londonderry NH 03053 Print Date: 2021-04-30 603-432-8221 jsnowde n @ham pshirefire.com Report of Inspection/Test General Questions OWNER SECTION Has the occupancy classification and hazard of contents 2 yes Are all fire protection systems in service? Yes remained the sarne since the last inspection? 0 No El No 0 NA El NA Has the system(s)remained in service without modification 0 Y(,s Was the systern(s)free of actuations of devices or alarms 2 Yes since the last inspection? [A No since the last inspection? E) No 0 NA 0 NA FIRE DEPARTMENT CONNECTION Is the FDC plainly visible? L"I Yes Is the FDC easily accessible? B Yes C3 No El No Ll NA E3 NA Is the FDC swivels and couplings not damaged? 0 YOS Are the FDC caps and plugs in place? B Yes El No 0 No El NA Ej NA Are the FDC gaskets in place and in good condition? 0Yes Is the FDC check valve drip free? 0 Yes El No ❑ No El NA L1 NA Is the clapper and automatic drain valve in place and 2 Yes Is the FDC identification sign(s)in place? Ed Yes properly operating? El No El No 0 NA El NA SPRINKLER HEADS Are visible sprinklers free of corrosion and physical 2 Vag Is there proper clearance below the sprinklers? Rl Yes damage? U No E) No El NA El NA Are visible sprinklers free of foreign materials including 2) Yes Is there liquid in all visible glass bulb sprinklers? R) Yes paint? El No 0 No 0 NA 0 NA Are all the sprinklers dated 1920 or later? (D Yes Have sprinklers Subject to harsh environments been El Yes El No replaced or successfully sample tested in the last 5 years? El No El NA Z NA Are all escutcheons properly in place and free of damage? 0 Yes Are all standard response sprinkler heads less than 75 RI Yes R) No years old or successfully sample tested within last 5 years? 171 No El NA El NA Are all standard response sprinklers less than 50 years old 0 Yes Are all dry-type sprinkler heads less than 10 years old or El Yes or successfully sample tested within last 10 years? El No Successfully sample tested within last 10 years? 0 No El NA Rl NA Are all fast response sprinkler heads less than 20 years old EJ Y11 Are there the proper number and type of spare sprinklers 2 Yes or successfully sample tested within last 10 years? n No and head wrench? 0 No 0 NA 0 NA Copyrig lit 2021 Inspect Point Page 1 of 9 Report of Inspection/Test Annual NFPA 25 QM�0�- FIRE PROTECTION 2021-04-30 Conducted by:Jim O'Sullivan CM.18C MONNNNFAMMOOMMMOMMERNW Property Manchester#W481 1060 Osgood Street MA Lie#SJ-001 500 TIA001 1060 Osgood Street Hampshire Fire Protection Co.,LLC North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowdcn@hampshirefire.com Are visible sprinklers in the proper position:upright, 0 Yes pendent,sidewall,recessed,etc.? LJ No [I NA PIPES Is the visible pipe in good condition with no external 2 yes Does visible pipe have no mechanical damage or leaks? 2 Yes corrosion? 0 No El No Lj NA El NA Does visible pipe have no external loads? 0' Yes Are visible pipe hangers and seismic braces not damaged RI Yes Ll No orloose? 0 No 0 NA ❑ NA VALVE AREA Is the hydraulic name plate(calculated systems)attached 0 yes Have the mechanical waterflow alarm devices passed tests [a Yes securely to the riser and legible? El No by opening inspector's test connectionibypass connection 0 No 0 NA with alarms actuating and flow observed? El NA The electrical waterflow alarm devices passed test by 2 Yes [lave post indicating valves been opened until spring or El Yes opening inspector's test connection/bypass connection with El No torsion felt in the rod and then closed back 1/4 turn? El No alarms actuating and flow observed? [I NA RI NA All control valves operated through full range and returned 0 Yes Are all control valves(including backflow preventer isolation R Yes to norrnal position? 0 No valves)in the correct(open or closed)position? El No n NA El NA Are all control valves(including backflow preventer isolation 0 Yes Are all control valves(including backflow preventer isolation Fv Yes valves)properly supervised(electrically monitored,locked El No valves)accessible? El No or sealed)? El NA 0 NA Are all control valves(including backflow preventer isolation R Yes Are all control valves and check valves externally Ov Yes valves)free from leaks? (:] No inspected,operating properly,and are in good condition? 171 No E) NA 0 NA_ Are main drain and auxiliary valves in good condition and 2 Yes Are all pressure gauges on system in good condition and 0 Yes identified with proper signage? D No showing normal water and air pressures? 0 No [I NA [I NA_ ALARMS Is the alarm valve free from physical damage? 2 Yes Is the Win in correct(open or closed)position? R) Yes El No 0 No El NA El NA_ Is there no leakage in the retarding chamber or drains? 2) Yes Are alarms and supervisory devices riot damaged? Cl Yes El No El No 0 NA 0 NA MAINTENANCE Operating stem of all OS&Y valves lubricated,completely ED Yes closed and reopened? 0 No El NA Copyright 2021 Inspect Point Page 2 of 9 Report of InspectionlTest Annual NFPA 25 ULiQWzV1.-4 FIRE PROTECT101M 2021-04-30 Conducted by:Jim O'Sullivan CO.,lie MMENSIMMENNEWMENNOMM Property Manchester#W481 1060 Osgood Street MA Lic#SJ-001500 TIA001 1060 Osgood Street Hampshire Fire Protection Co.,1.1-C North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowden@liampshirefire.com MISCELLANEOUS Has visual inspection of all sprinklered areas of the building ❑ Yes Date of last annual walk-through(visual inspection): 4/28/2021 performed within last year? ❑ No ❑ NA Copyright 2021 Inspect Point Page 3 of 9 Report of Inspection/Test Annual NFPA 25 ZMWMJl FIRE PROTECTION 2021-04-30 Conducted by:Jim O'Sullivan CO,,11C AIMNMMWffAVEREMMONOffMWMMW Property Manchester#W481 1060 Osgood Street MA Lic It SJ-001 5,00 TIA001 1060 Osgood Street Hampshire Fire Protection Co.,LLC North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowden@harnpshireflre.com Report of Inspection/Test for System - Wet 1 5 YEAR If due,size of lift needed: NIA INTERNAL PIPE INSPECTION Date of last 5-year internal pipe inspection? 5/20/2019 Date of next 5-year internal pipe inspection? 5/20/2024 Is system up-to-date with a scheduled 5 year internal pipe 2 Yes Are all gauges under 5 years old? 2 Yes inspection? 0 No EJ No Ej NA 0 NA Are areas protected by the wet system properly heated? R Yes El No 0 NA MAIN DRAIN FLOW TESTS System Initial static Residual Static Seconds to Flow Did waterflow Are results Return to Observed? alarm operate? comparable Initial Static to previous test? Wet 1 95 85 95 2 Yes Yes Yes INSPECTORS TEST CONNECTION Systern Location Description Time Reported? Smooth Easily Signs? Pass? to Orifice Accessible Alarm (seconds) Wet I 2nd floor AFS ITV 60 Yes Yes Yes Yes Yes space(directly above riser room) VALVES Flow/ of Tern valva Easily Steins Turn per System Description Location Type Size Secured Open Accessible Signs Exercised Lubricated s Pass wet I System Rearriser OS&Y 4" Monitored Yes Yes Yes Yes Yes 3 Pass control valve room DELETE DELETE Sectional N/A NIA N/A N/A N/A NIA ENTERED ENTEREDIN IN ERROR ERROR DRAIN VALVES systern I Description Location Drain Aux Drain Drained Water Flow Observed- I I Copyright 2021 Inspect Point Page 4 of 9 Report of Inspection/Test Annual NFIPA 25 ULU991M� FIRE PROTECTION 2021-04-30 Conducted by:Jim O'Sullivan CO..11C NAVEMONERINSUNKINENNUff Property Manchester#W481 1060 Osgood Street MA Lic#SJ-001500 TIA001 1060 Osgood Street Hampshire Fire Protection Co., LLC North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date: 2021-04-30 603-432-8221 jstiowden@hampshirefire.coni Wet 1 Main drain At riser Angle Valve NfA Yes Copyright 2021 Inspect Point Page 5 of 9 Report of Inspection/Test Annual NFPA 25 ML6Q� FIRE PROTECTION 2021-04-30 Conducted by:Jim O'Sullivan CO.,UC AIMMMEMMIMMERMENMEMEM Property Manchester#W481 1060 Osgood Street MA Lic#SJ-001500 TIA001 1060 Osgood Street Hampshire Fire Protection Co., LLC North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowden@hampshirefire.coni Deficiencies -General Questions Copyright 2021 Inspect Point Page 6 of 9 Report of Inspection/Test Annual NFPA 25 FIRE PROTECTION 2021-04-30 Conducted by:Jim O'Sullivan Co.,11C MEMMOMEMENEWOMMENSM Property Manchester#W481 1060 Osgood Street MA Lic#SJ-001 500 TIA001 1060 Osgood Street Hampshire Fire Protection Co., 1.1-C North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowden@hampshirefire.com Are all escutcheons properly in place and free of damage? No Slatus:Novi CHUcaI Notes: Missing outoroscutchoons;center stairwell(xl),former advanced fuel solutions space(xl).HP TAX&accounting space(xl).Martial arts studio(xl Reliable model G screw on outer escutcheon) AM ---------- 1f Copyright 2021 Inspect Point Page 7 of 9 Report of InspectionlTest Annual NFPA 25 zla� FIRE PROTECTIOM 2021-04-30 Conducted by:Jim O'Sullivan CO"tic MLUMMOMMMENWAMMaimm Property Manchester#W481 1060 Osgood Street MA Lic#SJ-001500 TIA001 1060 Osgood Street Hampshire Fire Protection Co., LLC North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowden ,hampshiretire.com I Deficiencies -General Wet System Questions None [Deficiencies -Wet 1 None Deficiencies-Inspectors Test Connection None Deficiencies-Valves None Deficiencies -Drain Valves None Copyright 2021 Inspect Point Page 8 of 9 Report of InspectionlTest Annual NFPA 25 FIRE PROTECTION 2021.04-30 Conducted by:Jim O'Sullivan CO"fie MMESHIMMMIMMOMMMMUMM Property Manchester#W481 1060 Osgood Street MA Lic#SJ-00 1500 TIA001 1060 Osgood Street Hampshire Fire Protection Co., LLC North Andover MA 8 North Wentworth Avenue David Samuels Londonderry NH 03053 Print Date:2021-04-30 603-432-8221 jsnowderi@harnpshirefire.com Inspector Signature I state that the information on this form Is correct at the time and place of my inspection,and all equipment tested at this time was left in operational condition upon completion of this inspection except as rioted. Inspector Name Signature Date Completed Jim O'Sullivan 2021-04-30 Client Signature I state that the information on this form is correct at the tirne,and place of my inspection,and all equipment tested at this time was left in operational condition upon completion of this inspection except as rioted. Client Name Signature Date Completed Dave-Covid 19 2021-04-30 Copyright 2021 Inspect Point Page 9 of 9