HomeMy WebLinkAboutAnnual NFPA 25 Inspection Report - Inspection - 757 TURNPIKE STREET 2/25/2021 Report of Inspection/Test Annual NFPA 25 26 Hampshire DR,Hudson,NH (603)293-7531 2021-02-25 Conducted by:Spencer Morse 261 Brooks ST,Worcester,MA Property (508)852-7227 STOP&SHOP#92 Impact Fire Services-Hudson 44 Garden ST,Suite 1,Danvers,MA 110073 (978)304-1506 Building*312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 "c Report of Inspection/Test General Questions OWNER SECTION is the building occupied? Yes Has the occupancy classification,hazard of contents, Yes and/or storage method remained the same since the last inspection? Are all fire protection systems in service? Yes Has the system remained in service without Yes modification since the last inspection? Was the system free of actuations of devices or alarms Yes since the last inspection? FIRE DEPARTMENT CONNECTION Has the interior of the FDC been inspected for N/A is the visible piping supplying the FDC undamaged? N/A obstructions? If locking caps/plugs are in place,has an internal N/A Is the FDC plainly visible and easily accessible? N/A inspections been conducted? Is the FDC easily accessible? N/A Are the FDC swivels and couplings not damaged? N/A Are the FDC caps and plugs in place and undamaged? NIA Are the FDC gaskets in place? N/A Is the FDC check valve free of leaks? N/A Is the clapper and automatic drain valve in place and N/A property operating? Is the FDC identification sign(s)in place? N/A I SPRINKLER HEADS Are there the proper number and type of spare N/A Are visible sprinklers in the proper position:upright, N/A sprinklers with a list in place? pendent,sidewall? Are visible sprinklers free of corrosion and physical N/A Is there proper clearance below the sprinklers? N/A damage? Are visible sprinklers free of foreign materials including N/A Is there liquid in all visible glass bulb sprinklers? N/A foreign paint? Are there spare sprinklers and a sprinkler wrench? N/A Is the information sign attached and legible? N/A Are all the sprinklers dated 1920 or later? N/A Past response sprinklers 20 or more years old replaced N/A or successfully sample tested within last 10 years? Standard response sprinklers 50 or more years old N/A Standard response sprinklers 75 or more years old N/A replaced or successfully sample tested within last 10 replaced or successfully sample tested within last 5 years? years? Dry-type sprinklers replaced or successfully sample N/A Have sprinklers subject to harsh environments been N/A tested within last 10 years? replaced or Successfully Sample tested in the last 5 years? PIPES Are the visible pipe and fittings in good condition with N/A Do visible pipe and fittings have no mechanical damage N/A no external corrosion? I or leaks? Copyright 2021 Inspect Point Page 1 of 7 Report of Inspection/Test Annual NFPA 25 26 Hampshire OR,Hudson,NH (603i293.7531 2021-02-25 Conducted by:Spencer Morse 261 Brooks ST,Worcester,MA Property (soa)852-7227 STOP&SHOP#92 Impact Fire Services-Hudson 44Garden ST,Suite 1,Danvers,MA 110073 (478)304-1506 Building#:312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 Does visible pipe have no external loads? NIA Are visible pi e hangers and seismic braces not NIA damaged or loose? is the pipe through freezers free if any ice blockage? NIA Has an internal investigation of the pipe been NIA performed in the last 5 years?(If no,conduct investigation) CONTROL VALVE AREA Are the control valves with electrical supervision in N/A Are the control valves with electrical supervision locked NIA correct(open or closed)position? or is supervision in place? Are the control valves with electrical supervision NIA Are the control valves with electrical supervision free WA accessible? from any leaks? Are the control valves with electrical supervision have NIA Are the control valves with electrical supervision NIA the appropriate wrenches? properly identified? Are the control valves supervised with seals in correct Yes Are the control valves supervised with seals locked or is Yes (open or closed)position? supervision in place? Are the control valves supervised with seals accessible? Yes Are the control valves supervised with seals free from Yes leaks? Are the control valves supervised with seals have Yes Are the control valves supervised with seals properly Yes appropriate wrenches? identified? Are the control valves with locks in correct(open or NIA Are the control valves with locks locked or is supervision NIA closed)position? in place? Are the control valves with locks accessible? N/A Are the control valves with locks free from any leaks? NIA Are the control valves with locks have the appropriate NIA Are the control valves with locks properly identified? N/A wrenches? VALVE AREA Are the gauges on system showing normal water supply Yes Are all check valves internally inspected,operating N/A pressure? properly,and are in good condition? Are the gauges on system operable and in good working NIA Is the hydraulic name plate(calculated systems) NIA condition? attached securely to the riser and legible? Are Pressure reducing valves(sprinkler system)in open N/A Are Pressure reducing valves(sprinkler system)with NIA position and not leaking? downstream pressure per the design? Are Pressure reducing valves in good condition including NIA Have the mechanical waterflow alarm devices passed NIA no handwheels broken? tests by opening inspector's test connection/bypass connection with alarms actuating and flow observed? Do valve supervisory switches indicate movement? NIA The electrical waterflow alarm devices passed test by N/A opening inspector's test connection/bypass connection with alarms actuating and flow observed? Have post indicating valves been opened until spring or N/A All control valves operated through full range and Yes torsion felt in the rod and then closed back 1/4 turn? returned to normal position? Have pressure reducing valves passed partial flow test? NIA BACKFLOW.PREVENTERS Copyright 2021 Inspect Point Page 2 of 7 Report of Inspection/Test . Annual NFPA 2S y 1.C�t�..l:�.��.C.;If :'Ix��.:; 26 Hampshire FAR,Hudson,NH (603)293-7531 2021-02-25 Conducted by:Spencer Morse 261 BrooksST,Worcester,MA Property (sob)852-7227 STOP&SHOP#92 impact Fire Services-Hudson 44 Garden 5T,5ufte1,Danvers,MA 110073 (9781304-1506 Building#:312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 Is relief port on RPZ device not discharging? NIA Have backflow devices passed forward flow test? NIA ALARMS Is the alarm valve free from physical damage? NIA Is the trim/valves in correct(open or dosed)position? N/A Is there no leakage in the retarding chamber or drains? Yes Are alarms and supervisory devices not damaged? NIA Do low temperature alarms look ok? N/A MAINTENANCE If a sprinkler failed a sample testwere all the sprinklers N/A if sprinklers have been replaced,were they proper N/A represented by that sample replaced? replacements? Were marine systems normally having fresh water NIA Was heat tape inspected per the manufacturer's NIA drained and refilled twice if raw water got into the instructions? system? If conditions were found that required flushing,was N/A Have adjusted,repaired,reconditioned,or replaced NIA flushing of the system conducted? components had proper tests/inspections performed? Was a drain test conducted after opening any closed N/A Operating stem of all OS&Y valves lubricated,completely NIA valve? closed and reopened? Have sprinklers and spray nozzles protecting NIA commercial cooking equipment and ventilating systems been placed annually? Copyright 2021 Inspect Point Page 3 of 7 Report of Inspection/Test _.� .,__ ;- -a Annual NFPA 25 i 11M 11 C [ II I 1 Zfi Hampshire DR,Hudson,NH (603)293-7531 2021-02-25 Conducted by:Spencer Morse 261 Brooks ST,Worcester,MA Property (5081 a52-7227 STOP&SHOP#92 Impact Fire Services-Hudson 44Garden ST,suite 1,Danvers,MA 110073 (978)304-1506 Building#:312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 Report of Inspection/Test for.System -Inlet #1 FIRE DEPARTMENT CONNECTION Has the FDC been hydrostatically tested as required Date of the last FDC hydrostatic test? NIA every 5 years? ANTIFREEZE Can antifreeze type be correctly identified? Is the antifreeze listed? Is expansion tank pressure reading equal to 90%of supply? Report of Inspection/Test for System -Wet #2 FIRE DEPARTMENT.CONNECTION Has the FDC been hydrostatically tested as required Date of the last FDC hydrostatic test? NIA every 5 years? ANTIFREEZE Can antifreeze type be correctly identified? is the antifreeze listed? Is expansion tank pressure reading equal to 90%of supply? Report of Inspection/Test for Asset - Antifreeze #1 (trash compactor) ANTIFREEZE Is the specific gravity of antifreeze correct at the most Yes Is the specific gravity of antifreeze correct at the Yes remote point? interface with wet system? Is the specific gravity of antifreeze correct at other test NIA Is the antifreeze the correct type? Yes points(over 150 gal)? Is the antifreeze placard on-site and does it indicate Yes Are freeze points at all test locations within Yes manufacturer type and brand of antifreeze solution,and recommended range based on region? volume of antifreeze solution in loop? Report of inspection/Test for Asset - Antifreeze #2 (redemption center) ANTIFREEZE Is the specific gravity of antifreeze correct at the most Yes Is the specific gravity of antifreeze correct at the Yes remote point? interface with wet system? Is the specific gravity of antifreeze correct at other test NIA is the antifreeze the correct type? Yes points(over 150 gal)? Is the antifreeze placard on-site and does it indicate Yes Are freeze points at all test locations within Yes manufacturer type and brand of antifreeze solution,and recommended range based on region? volume of antifreeze solution in loop? Copyright 2021 Inspect Point Page 4 of 7 Report of Inspection/Test .. Annual NFPA 25 26 Hampshire DR,Hudson,NH 1603)293-7531 2021-02-25 Conducted by:Spencer Morse 261 Brooks ST,Worcester,MA Property (50H)852-7277 STOP&SHOP#92 Impact Fire Services-Hudson 44 Garden ST,Suite 1,Danvers,MA 110073 i978)304-1506 Building#:312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 Report of Inspection/Test for Asset - Antifreeze #3 (receiving) ANTIFREEZE Is the specific gravity of antifreeze correct at the most No Is the specific gravity of antifreeze correct at the No remote point? interface with wet system? Is the specific gravity of antifreeze correct at other test N/A is the antifreeze the correct type? Yes points(over 150 gal)? Is the antifreeze placard on-site and does it indicate Yes Are freeze points at all test locations within No manufacturer type and brand of antifreeze solution,and recommended range based on region? volume of antifreeze solution in loop? Copyright 2021 Inspect Point Page 5 of 7 Report of Inspection/Test Annual NFPA 25 26 Hampshire DR,Hudson,NH (603)293-7531 2021-02-25 Conducted by:Spencer Morse 261 Brooks ST,Worcester,MA Property (508)852-7227 STOP&SHOP#92 Impact Fire Services-Hudson 44 Garden sr,Suite 1,Danvers,MA 110073 (978)304-1506 Building#:312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 Deficiencies-General Questions None Deficiencies-General Wet System Questions None Deficiencies-Wet#1 None Deficiencies-Wet#2 None Deficiencies-Antifreeze;#1 (trash compactor) None Deficiencies-Antifreeze#2(redemption center) None Deficiencies-Antifreeze#3(receiving) Is the specific gravity of antifreeze correct at the most remote point? No Status:Critical C t Notes; AFloop tested at31.596/+9°F Loop needs to be recharged.8gollons ofglycerine needed. r Is the specific gravity of antifreeze correct at the interface with wet system? No Status:Non Critical Notes: AFloop tested at 31.5%/+9°F.Loop needs to be recharged.8 gallons of glycerine needed. Are freeze paints at all test locations within recommended range based on region? No Status:Non Critical Notes: AF loop tested at 31.5%/+9°F Loop needs to be recharged.8gallons ofglycerine needed. Copyright 2021 Inspect Paint Page 6 of 7 Report of Inspection/Test ; ... Annual NFPA25 26 Hampshire DP,Hudson,NH (6031293-7531 2021-02-25 Conducted by:Spencer Morse 261 Brooks ST,Worcester,MA Property (sob)852-7227 STOP&SHOP#92 Impact Fire Services-Hudson 44 Garden ST,Suite 1,Danvers,MA 110073 {978)304-1506 Building#:312311 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Inspection Ref#:20857170 Inspector signature I state that the information on this form is correct at the time and place of my inspection,and all equipment tested at this time was left in operational condition upon completion of this inspection except as noted. Inspector Name Signature Date Completed Spencer Morse 2021-02-25 Client Signature I state that the information on this form is correct at the time and place of my inspection,and all equipment tested at this time was left in operational condition upon completion of this inspection except as noted. Client Name Signature Date Completed Dom Mondi 2021-02-25 Copyright 2021 Inspect Point Page 7 of 7