HomeMy WebLinkAbout- Consultant Review - 101 FOSTER STREET 10/18/2021 North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 101 Foster Street MAP: 104.D LOT: 0037 INSTALLER: James Boracezk – 978-479-5236 DESIGNER: Benjamin Osgood Jr. – 978-435-1324, bosgood@rangereng.com PLAN DATE: July 24, 2020 BOH APPROVAL DATE ON PLAN: revised August 24, 2020 INSPECTIONS TANK INSPECTION: 12.21.2020 S. Casey – 12:30pm pump and tank DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: 12.31.2020 D. Gallant DATE OF FINAL GRADE INSPECTION: 1/13/2021 SITE CONDITIONS Contractor reports any changes to design plan Existing septic tank properly abandoned Internal plumbing all to one building sewer Topography not appreciably altered Comments: 12/31/20 – Liberty 4/10hp pump installed instead of Hydromatic SEPTIC TANK Building sewer in continuous grade, on compacted firm base Cleanouts per plan Bottom of tank hole has 6” stone base Weep hole plugged 1500 gallon tank has been installed H-10 loading Monolithic tank construction Water tightness of tank has been achieved by visual testing Inlet tee installed, centered under access port Outlet tee installed, centered under access port (effluent filter) 24 inch cover to within 6” of finish grade installed over one access port Rubber boots installed around inlet & outlet Comments: PUMP CHAMBER Bottom of tank hole has 6" stone base Weep hole plugged 1000 gallon Pump Chamber installed H-10 loading Monolithic tank construction Inlet tee installed, centered under access port Pump(s) installed on stable base Alarm float working Pump On/Off floats working Separate on/off floats Drain hole in pressure line 24” cover at final grade installed over pump access port Water tightness of tank has been achieved by visual testing Rubber boots installed around inlet & outlet Comments: 12/31/20 – Liberty 4/10hp pump installed instead of Hydromatic CONTROL PANEL Alarm & Pump are on separate circuits Alarm sounds when float is tripped Location of control panel: side of house Alarm signal located inside: side of house Comments: DISTRIBUTION-BOX Installed on stable stone base H-20 D-Box Inlet tee (if pumped or >0.08’/foot) Hydraulic cement around inlet & outlets Observed even distribution Speed levelers provided (not required) Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) Bottom of SAS excavated down to C soil layer, as provided on plan – hit fill on side opposite of pool, removed to natural soil Size of SAS excavated as per plan 25x50’ Title 5 sand installed, if specified on plan 40 Mil HDPE barrier installed Laterals installed and ends connected to header (and vented if impervious material above) Elevations of laterals and chambers installed as on approved plan Retaining wall (boulder / concrete / timber/ block) Final cover as per plan Comments: large rock removed from bottom while on site, field expanded to meet 50x25’ requirment FINAL GRADE Loamed Seeded Cover per plan Comments: DOCUMENTS NEEDED Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM = 108.60 HR = 2.26__ HI = 110.86_ SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark 2.26 108.60 108.60 Building Sewer OUT Septic Tank IN 10.25 100.28 99.60 Septic Tank OUT 10.50 100.03 99.35 Pump Chamber IN 10.55 99.98 99.30 Pump Chamber OUT 10.40 100.13 99.05 Distribution Box IN 5.06 105.47 105.47 Distribution Box OUT 5.20 105.33 105.30 Lateral 1 BEGINNING 5.24 105.29 105.20 Lateral 1 END 5.57 104.96 105.00 Lateral 2 BEGINNING 5.30 105.23 105.20 Lateral 2 END 5.59 104.94 105.00 Lateral 3 BEGINNING 5.30 105.23 105.20 Lateral 3 END 5.59 104.94 105.50 12/31/20 – Building Sewer Out not able to be measured due to existing fill. Pitch into septic tank visually confirmed. Distance to wetlands confirmed to be >100’