ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 1010 Johnson Street MAP: 107.A LOT: 0137
INSTALLER: Dean Dynan — 508-726-9935 permit # 59800 vp
DESIGNER: James Kavanaugh — 978-375-9781 septic plan submittal #57113 vp
PLAN DATE: 10.20.2020
BOH APPROVAL DATE ON PLAN: 01 .21 .2021
INSPECTIONS
TANK INSPECTION: S. Casey — pump only 6.21.2021
DATE OF BED BOTTOM INSPECTION:6.17.2021 and 6.21 .2021 S. Casey
DATE OF FINAL CONSTRUCTION INSPECTION: 7/6/21 — D. Ottenheimer
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments: 7/6/21 — Existing septic tank examined by installer and determined to
be acceptable in terms of its physical integrity and tees and baffles. Effluent filter
exists on outlet side but there was no manhole cover to finished grade over it,
this was requested to be installed.
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments: 7/6/21 — Existing tank was not inspected, but did request manhole to
finished grade over effluent filter
PUMP CHAMBER
® Bottom of tank hole has 6" stone base
® 1000 gallon Pump Chamber installed
® H-20loading
® Monolithic tank construction
® Inlet tee installed, centered under access port
® Pump(s) installed on stable base
® Alarm float working
® Pump On/Off floats working
® Drain hole in pressure line
® 24" cover at final grade installed over pump
access port
® Water tightness of tank has been achieved by
visual testing
® Rubber boots around inlet & outlet
Comments: 7/6/21 — Floats not adequately secured to float mast, requested
additional securing mechanism
CONTROL PANEL
® Alarm & Pump are on separate circuits
® Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments-
DISTRIBUTION-BOX
❑ Installed on stable stone base
® H-20 D-Box
® Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
® Observed even distribution
❑ Speed levelers provided (not required)
® Schedule 40 PVC Pipe
Comments: 7/6/21 — Hydraulic cement needed at pipe penetrations
SOIL ABSORPTION SYSTEM (General)
® Bottom of SAS excavated down to C soil layer,
as provided on plan
® Size of SAS excavated as per plan
® Title 5 sand installed, if specified on plan
® 40 Mil HDPE barrier installed
® Laterals installed and ends connected to
header and vented
® Elevations of laterals installed as on
approved plan
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments: Pass on 6.21.2021 — S. Casey. 7/6/21 — Sand fill contained
considerable fines. Sample collected for laboratory analysis.
FINAL GRADE
❑ Loamed
❑ Seeded
❑ Cover per plan
Comments:
DOCUMENTS NEEDED
❑ Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
❑ As-Built Plan
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark 1.01
Building Sewer OUT 95.75
Septic Tank IN 95.40
Septic Tank OUT 95.15
Pump Chamber IN 94.50
Pump Chamber OUT 94.25
Distribution Box IN 2.54 98.14 98.12
Distribution Box OUT 2.72 97.96 97.95
Lateral 1 BEG 2.81 97.87 97.90
Lateral 1 END 3.10 97.58 97.55
Lateral 2 BEG 2.78 97.90 97.90
Lateral 2 END 3.12 97.56 97.55
Lateral 3 BEG 2.81 97.87 97.90
Lateral 3 END 3.12 97.56 97.55
7/6/21 —Did not check elevations of septic tank and pump tank, visually seemed
approporiate.
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
❑ Property line 10 10 --
❑ Cellar wall 10 20 --
❑ Inground pool 10 20 --
❑ Slab foundation 10 10 --
❑ Deck,on footings, etc 5 10 --
❑ Waterline 10 10 101
❑ Private drinking well 75 1002 50
❑ Irrigation well 75 100
❑ Surface Water 25 50
❑ Bordering Vegetated Wetland ,
Salt Marsh,Inland/Coastal Bank3 75 100
❑ Wetlands bordering surface
water supply or trib. (in Watershed) ISO 150
❑ Trib. to surface water supply 325 325
❑ Public well 400 400
❑ Interim Wellhead Prot. Area
❑ Reservoirs 400 400
❑ Drains(wat. supply/trib.) 50 100
❑ Drains(intercept g.w.) 25 50
❑ Drains(Other)Foundation 10(5) 20(10)
❑ Drywells 20 25
1 Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws
C.0
5-1
North Andover Health Department
(ommunity and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 1010 Johnson Street MAP: 107.A LOT: 0137
INSTALLER: James Boraczek — 978 479 5236 permit #62464
DESIGNER: James Kavanaugh — 978-375-9781 septic plan submittal #57113 vp
PLAN DATE: 10.20.2020
BOH APPROVAL DATE ON PLAN: 01.21.2021
Note: This is a new permit as the original installer, Dean Dynan, was fired from
the job by the new homeowners. The old permit number for this project was
#59800.
INSPECTIONS
TANK INSPECTION: S. Casey— pump only 6.21.2021 (occurred on permit
#59800)
DATE OF BED BOTTOM INSPECTION: 9.23.21 — S. Casey
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
® Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
❑ Installed on stable stone base
❑ H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
❑ Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTEM (General)
q(n ® Bottom of SAS excavated down to C soil layer,
as provided on plan
® Size of SAS excavated as per plan
® Title 5 sand installed, if specified on plan
❑ 40 Mil HDPE barrier installed
..S„SL� �e k41 ►1� ❑ Laterals installed and ends connected to
header (and vented if impervious material
above)
t^ 1� ❑ Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments: Size was previously confirmed at original bottom of bed. New bottom
of bed is only to ensure all sand that did not meet Title 5 requirements was
removed, bed bottom was empty, and new sand was acceptable.
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
❑ Brand and Model of Chamber: Standard Quick
4 Infiltrator Chambers
❑ Number of chambers per row:
❑ Number of rows (trenches):
Comments: Total Chambers =
FINAL GRADE
❑ Loamed
❑ Seeded
❑ Cover per plan
Comments:
DOCUMENTS NEEDED
❑ Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
❑ As-Built Plan
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
- Benchmark --- - -
Building Sewer OUT
- -- -
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
Distribution Box OUT
Lateral 1 TOP
Lateral 1 INVERT
Lateral 2 TOP
Lateral 2 INVERT
Lateral 3 TOP
Lateral 3 INVERT
Lateral 4 TOP
Lateral 4 INVERT
Lateral 5 TOP
Lateral 5 INVERT
Lateral 6 TOP
Lateral 6 INVERT
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 10 10 --
® Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck, on footings, etc 5 10 --
® Waterline 10 10 l 0 1
® Private drinking well 75 1002 50
® Irrigation well 75 100
® Surface Water 25 50
® Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
® Trib. to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot.Area
® Reservoirs 400 400
® Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
® Drains(Other)Foundation 10(5) 20(10)
® Drywells 20 25
' Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws
So,l p
�a
y�ITt.en t c)
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 1010 Johnson Street MAP: 107.A LOT: 0137
INSTALLER: Dean Dynan — 508-726-9935 permit # 59800 vp
DESIGNER: James Kavanaugh — 978-375-9781 septic plan submittal #57113 vp
PLAN DATE: 10.20.2020
BOH APPROVAL DATE ON PLAN: 01.21.2021
INSPECTIONS
TANK INSPECTION:
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
0 Bottom of tank hole has 6" stone base
bl G ❑ Weep hole plugged
�` ❑ 1500 gallon Pump Chamber installed
❑ H-10loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROLPANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
❑ Installed on stable stone base
❑ H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
❑ Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTEM (General)
❑ Bottom of SAS excavated down to C soil layer,
as provided on plan
6/2t _ ,A&5 Size of SAS excavated as per plan
E*� Title 5 sand installed, if specified on plan
❑ 40 Mil HDPE barrier installed
❑ Laterals installed and ends connected to
header (and vented if impervious material
above)
❑ Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete / timber/ block)
❑ Final cover as per plan
Comments- -re
vs"Ap w 62-bri" �w t't�6Ay
SOIL ABSORPTION SYSTEM (G aswzs�e�r s« ews4 boll, , Sc-
El
.5'y
❑ _
Comments- Total Chambers
-
FINAL GRADE
❑ Loamed _
❑ Seeded
❑ Cover per plan
Comments.-
DOCUMENTS NEEDED
❑ Certification of Installation Fc
By engineer and signed and
Engineer and installer
❑ As-Built Plan
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
Distribution Box OUT
Lateral 1 TOP
Lateral 1 INVERT
Lateral 2 TOP
Lateral 2 INVERT
Lateral 3 TOP
Lateral 3 INVERT
Lateral 4 TOP
Lateral 4 INVERT
Lateral 5 TOP
Lateral 5 INVERT
Lateral 6 TOP
Lateral 6 INVERT
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 10 10 --
® Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck,on footings, etc 5 10 --
® Waterline 10 10 10'
® Private drinking well 75 1002 50
® Irrigation well 75 100
® Surface Water 25 50
® Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
® Trib.to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot. Area
® Reservoirs 400 400
® Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
® Drains(Other)Foundation 10(5) 20(10)
® Drywells 20 25
Suction line 222(2)
z 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
'As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws