HomeMy WebLinkAbout2016-04-05 As Built Plan 1661 GPR 7-6-17 - As-Built Plan / Installation Certificate Form - 1665 GREAT POND ROAD 4/5/2016 and®Ver 1 Fast diver Place
�\ consultants Methuen, Massachusetts 01844
Tel. (978) 687-3828
inc. Fax (978) 686-5100
www,aridoverconsultants.com
July 12, 2017
North Andover Planning Board
c/o Jean Enright, Planning Director
Town Offices
120 Main Street
North Andover, MA 01845
RE: Watershed Special Permit
1661 Great Pond Road
Dear Members of the Board:
As required by the Watershed Special Permit Notice of Decision, Special Conditions 46, our office has
completed an as-built survey of the property for the project referenced above. Andover Consultants,
Inc. was not retained to conduct inspections during construction so the attached plan depicts site
features that were visible, or accessible from the surface, at the time of the survey only.
Based upon a comparison of the original design plan titled "Site Plan Great Pond Road Road", dated
March 28, 2013 and revised June 3, 2013,prepared for Technical Training Foundation Trust with the
attached plan titled "As-Built Plan 1661 Great Pond Road" dated July 6, 2017, prepared for TKZ, LLC
and a field inspection conducted on June 19, 2017, it is my opinion that the project was completed in
reasonable compliance with the approved plan.
The following minor differences are noted for your reference:
• The as-built driveway is more irregularly shaped and generally further west than the one
depicted on the approved plan, the as-built sidewalk is smaller and starts further west than that
depicted on the plan, but the dwelling foundation footprints are the same. As a result, the as
built impervious area is approximately 60± square feet, only, more than the proposed
impervious area.
« The stone swale is also more irregularly shaped and wider than depicted on the approved plan.
• A bulkhead was constructed in the back of the dwelling which was not depicted on the
approved plan.
• There is a rear stair constructed over a crushed stone area which was not depicted on the
approved plan.
• There is 12-foot wide± crushed stone strip at the back of the drive that was not depicted on the
approved plan
® There is a deck on the back of the dwelling that was not depicted on the approved plan.
P'lY=F1il da_s'1. r2ii�7ai7-3?11'SY,ls[7;i1i Capisnce rfa
Civil Engineers o Lai id Surveyors o Land Planters
andover
consultants
ine.
On behalf of TKZ, LLC, we respectfully request that the Board release the performance bond being
held for this project.
Please find attached two frill sized and eight reduced sized copies of the as-built plan. .
If you have any questions concerning this request, or require anything further, please feel free to
contact us at your convenience.
Sincerely,
ANDOVER CONSULTANTS, INC.
Janes S. Fairweather II, P.E.
Civil Engineer
Enclosures
Cc: TKZ, LLC
P 111.5292cFxs`fctud3o u-u7-I2_ri->P as 13i11 Cea:pli=nc:��
/D..(I.D V r Y
NR � �� �' +
_IKIEN A. �<<- LOT fl 0 ltv I h r
m Y / IN IN
42.720 S.F.
1s �w:T
NA
Nona
\ r
POND
o. \��� •..�.. ,� \
,Nz LLc
tin ----
� awcarV __ - _' ''«.nan• - �,....' '�"p�,_.,. \ �� \�PvR'"oro ..la'"(��1 S
—
- m ABU!LT PLAN N
�� ��---.-.-.-�-� ---�-- ---------------- _ 1661 GREAT POND ROAD
----- — �,,— — \max -- -- --- NORTH ANDOVER, MASS.
r' PREPARED FORS TKZ.LLC
DATE:
'20 017
1ma s..,vo,r
OAiE: JUL
- ---- ---- ----- - PO
GR N4 - - -
S"'" ` __ andaver -a
f 11 '\consultants
t�y N� MaMvan,Movx.0�844 Rag.Pral.LanC S�rwyor
LAKE CCCHICHEWICK o 20 AO so 80 Ft.
v:Vx\r2-]xAG1YG\A,'puiLT,66,.CI5G �^ p 9 to 20
Mtter