HomeMy WebLinkAboutConstruction Notes - Consultant Review - 432 SALEM STREET 11/17/2021
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 432 Salem Street MAP: 037.B LOT: 0052
INSTALLER: Tom Sawyer, Arco Excavators 603-895-0111
DESIGNER: Jack Sullivan 781-854-8644
PLAN DATE: 07.09.2021
BOH APPROVAL DATE ON PLAN: 09.29.2021
INSPECTIONS
TANK INSPECTION: 08.17.2021
DATE OF BED BOTTOM INSPECTION: 08.19.2021
DATE OF FINAL CONSTRUCTION INSPECTION: 8/31/21, 10/29/21, 11/2/21
DATE OF FINAL GRADE INSPECTION: 11/2/2021
SITE CONDITIONS
Contractor reports any changes to design plan
Existing septic tank properly abandoned, if
present
Internal plumbing all to one building sewer
Topography not appreciably altered
Comments: 8/31/21 – As noted in previous communication, there is a building
sewer in the front of the dwelling as well as one in the rear. The house
configuration does not allow the installer to merge the two building sewer pipes
into one. A new design plan for a pump system to bring the sewage to the rear
will be provided. D. Ottenheimer
10/29/21 – Inspection completed to examine the septic tank and pump tank
installed in the front yard as well as the issues which remained unresolved in rear
yard from previous inspection. D. Ottenheimer
11/2/21 – Construction inspection to examine unresolved issues
SEPTIC TANK – FRONT YARD
Building sewer in continuous grade, on
compacted firm base
Cleanouts per plan
Bottom of tank hole has 6” stone base
Tank size and loading per plan
Monolithic tank construction
If monolithic, water tightness of tank has been
achieved by visual testing
If 2-piece, water tightness of tank has been
achieved by water / vacuum test (circle one)
Inlet tee installed, centered under access port
Outlet tee installed, centered under access port
effluent filter installed (circle one)
If effluent filter, riser to finished grade over filter
Riser with cover to within 6” of finish grade
installed over one access port
Manhole and riser minimum 24 inch diameter
Pipe penetrations appear watertight using
rubber boots
10/29/21 – Tank in front yard examined. Found to not be watertight. Likely at
pipe penetration on outlet, also possibly at risers. Very high water table showed
infiltration. D. Ottenheimer
11/2/21 – Hydraulic cement placed around riser/tank interface and riser/lid
interface and better securing mechanism provided at pipe penetration.
Watertightness has been demonstrated satisfactorily. D. Ottenheimer
SEPTIC TANK - REAR YARD
Building sewer in continuous grade, on
compacted firm base
Cleanouts per plan
Bottom of tank hole has 6” stone base
Tank size and loading per plan
Monolithic tank construction
If monolithic, water tightness of tank has been
achieved by visual testing
If 2-piece, water tightness of tank has been
achieved by water / vacuum test (circle one)
Inlet tee installed, centered under access port
Outlet tee installed, centered under access port
Effluent filter installed
If effluent filter, riser to finished grade over filter
Riser with cover to within 6” of finish grade
installed over one access port
Manhole and riser minimum 24 inch diameter
Pipe penetrations appear watertight using
rubber boots / hydraulic cement (both)
Comments: 10/29/21 – Force main where it enters septic tank in rear yard is
plumbed into the outlet side of the septic tank and will need to be plumbed into
the inlet side of the septic tank. D. Ottenheimer
11/2/21 – Force main moved to inlet side of septic tank and tee installed. Tee
not under opening in tank and is to be adjusted. Also watertightness of former
opening on outlet side of the tank needs to be demonstrated. Do. Ottenheimer
PUMP CHAMBER
Bottom of tank hole has 6" stone base
Weep hole plugged
1000 gallon Pump Chamber installed
H-10 loading
Monolithic tank construction
Inlet tee installed, centered under access port
Pump(s) installed on stable base
Alarm float working
Pump On/Off floats working
Drain hole in pressure line
__” cover at final grade installed over pump
access port
Water tightness of tank has been achieved by
Visual or watertightness testing
Neoprene boots around inlet & outlet
Comments: 8/31/21 – Pump and alarms not yet installed. D. Ottenheimer
10/29/21 – Pump was unable to be made operational. D. Ottenheimer
11/2/21 – Pump and alarm demonstrated to properly function. D. Ottenheimer
CONTROL PANEL – FRONT YARD PUMP
(Delete if not present) Alarm & Pump are on separate circuits
Visual & audible alarm works as intended
Location of control panel: Right outsde wall of
house
CONTROL PANEL – REAR YARD PUMP
(Delete if not present) Alarm & Pump are on separate circuits
Visual & audible alarm works as intended
Location of control panel: Rear wall of house
DISTRIBUTION-BOX
Installed on stable stone base
H-20 D-Box
Inlet tee (if pumped or >0.08’/foot)
Hydraulic cement around inlet & outlets
Even distribution observed
Schedule 40 PVC Pipe
Comments: 8/31/21 – Hydraulic cement needed at pipe penetrations. D.
Ottenheimer
10/29/21 – Observed hydraulic cement around pipe penetrations. D.
Ottenheimer
SOIL ABSORPTION SYSTEM (General)
Bottom of SAS excavated down to specified
soil layer, as provided on plan
Size of SAS excavated as per plan
Sand installed, if specified on plan
Sand displays few fines when handled
40 Mil HDPE barrier installed, if specified on
design plan
Laterals installed and ends capped or
connected to header (and vented)
Retaining wall material, location and height if
specified on plan
Comments:
FINAL GRADE
Final cover as per plan
Loamed
Seeded
Cover per plan
Comments:
DOCUMENTS NEEDED
Certification of Installation Form submitted
by designer and signed and dated by
designer and installer
As-Built Plan by designer
BM = 100.00
HR = 1.03
HI = 101.03
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT 4.13 96.57 96.30
Septic Tank IN 4.50 96.20 96.05
Septic Tank OUT 4.70 96.00 95.80
Pump Chamber IN 4.70 96.00 95.78
Pump Chamber OUT 95.53
Distribution Box IN 3.68 97.18 97.17
Distribution Box OUT 3.68 97.18 97.00
Lateral 1 BEGINNING 3.71 96.99 96.97
Lateral 1 END 4.00 96.70 96.70
Lateral 2 BEGINNING 3.71 96.99 96.97
Lateral 2 END 4.00 96.70 96.70
Lateral 3 BEGINNING 3.71 96.99 96.97
Lateral 3 END 4.00 96.70 96.70
Lateral 4 BEGINNING 3.71 96.99 96.97
Lateral 4 END 4.00 96.70 96.70
Lateral 5 BEGINNING 3.71 96.99 96.97
Lateral 5 END 4.03 96.67 96.70