HomeMy WebLinkAboutSprinkler Inspection Report - Inspection - 815 CHESTNUT STREET 11/12/2021 pv 1Qd Y y A.S.A.P. Sprinkler LLC SPRINKLER INSPECTION REPORT PAGE 1 6 Progress Ave. Unit #3 Tyngsboro, Ma. 01 Pho a 8-649-4945 Fax 978-649-9445 Company Name Cont ct Street City/ ? State Date of Trip Test T Technician c-X Date Owners Section(To be answered by owner or occupants 1J A. Explain any occupancy hazard changes since the previous inspection. 1�� B,Describe fire protection modifications made since the last inspection. ! o v C. Describe any fires since the last inspection D. When was the system piping last checked for stoppage,corrosion or foreign material? 4L"/Z1--Y-rs✓s'7 E.When was the dry-piping system last checked for proper pitch? .F%3 rL r LA- F.Are dry valves adequately protected from freezing? Inspector's Section(AII responses reference current inspection) 1. GENERAL YES NO a. Is the building occupied? 14 b.Are all systems in service? c. Is there a minimum of 18 in clearance between the tap of storage and sprinkler deflector? d.In areas protected by wet system,does the building appear to be properly heated in all areas including blind attics and perimeter areas,where accesible? Do all exterior openings appear to be protected against freezing 2. CONTROL VALVES(See Item 14) XXXXXXXXX XXXXXXXXX a.Are all sprinkler system control valves and all other valves in appropriate position? b.Are all control valves in the open position and locked,sealed or equipped with tamper? 3.WATER SUPPLIES(see Item 14) XXXXXXXXX XXXXXXXXX a.Was a water(tow test of main drain made at the sprinkler riser? 4.TANKS,PUMPS, FIRE DEPARTMENT CONNECTIONS XXXXXXXXX XXXXXXXXX a.Are fire pumps,gravity tanks,reserviors and pressure tanks in good condition and maintained? b.Are FD connection in satisfactory condition,couplings free,caps in place&check valves tight? Are they accessible and visible? �� S.WET SYSTEMS(See Item 13) XXXXXXXXX XXXXXXXXX a.Are cold weather valves(OS&Y)in the appropriate open or closed position? b. Have anti-freeze system solutions been tested? c.Were the antifreeze test results satisfactory? 6. DRY SYSTEMS (See Items 10-14) XXXXXXXXX XXXXXXXXX a.Is the dry valve in service? S°/' b.Are the air pressure&priming water level in accordance with the manufacturers instructions? c.Were the antifreeze test results satisfactory? / d.W're low points drained during the inspection? e. Did quick-opening devices operate satisfactory? f. Did the dry valve trip properly during the trip pressure test? g.Did the heating equipment in the dry-pipe valve room operate at the time of inspection? 7.SPECIAL SYSTEMS(See item 16) XXXXXXXXX XXXXXXXXX a. Did the deluge or pre-action valves operate properly during testing? b. Did the heat-responsive devices operate properly doring'testing? c. Did the supervisory alarm service test satisfactory? 8.ALARM$ XXXXXXXXX XXXXXXXXX a. Did water motor and gong test satisfactory? ft1{1 - b. Did electric alarm test satisfactory? c. Did supervisory alarm service test satisfactory? 9.SPRINKLERS XXXXXXXXX XXXXXXXXX a.Are all sprinklers free from corrosion,loading or obstruction to spray discharge? b.Are sprinklers over 50 years old, thus requiring sample testing? c. Is stock of spare sprinklers available? d. Does the interior condition of sprinkler system appear to be satisfactory e.Temperature.Are sprinklers of proper temperature rating for their location? /'047 r Dry Pipe Valve 1 Pre-Action Test Report A.S.A.P. SPRINKLER, LLC 6 PROGRESS AVE., UNIT#3, TYNGSBORO, MA Ol 879 . 978-649-4945 • Fax.: 978-649-9445 Company Name: _6_ `�.' Ile Contact: Street: � ' � � City: 1r° <' State: 'fie( r Date of Trip Test: %' '�Technician: _���dt'r�i�"�/��.-�-�=� Date: Note: Before any dry pipe valve is trip tested,the water supply line to it should be thoroughly flushed,the two inch drain below the valve should be opened wide,and water at full pressure should be discharged long enough to clear the pipe of any accumulation of scale or foreign material.The DRIP VALVE on the dry pipe vaive should be checked before tripping the pipe valve to see that it is operating properly. r r ■ E VALVES SYSTEM NO SYSTEM NO SYSTEM NO SYSTEM NO Valve Serial# J Manufacturer(Name) (,.j Valve Model Valve Size L 4` Controlling(Location) "im Sprinklers(Numbers) Date Last Trip Tested? ov tab Date Last Operated? Pressure(Air) Before Test(Water) } TD,4�s Size/location of Valve A�t f Was Gate Valve Opened Wide During Test Air(Air Pressure) (] Tripped(Water) !! At(Time) . I~ i CL If System Flooded,Time If Flooded Water Reached Test Opening Performance Valve Cond lnt of Body pb Moving Parts Rubber Facing Seats Reset? Did Alarms Operate @ Trip Test All Low Poin Drains Blown Out? H2O Control Valve Open/Sealed Alarm Con.Valve Open/Sealed Quick Opening Devices 1� Device Serial Number Manufacturer(Name) TypeAnd Model Air Pressure In Upper Chamber Quick Opening Device Tripped at Performance Left In Sery Open/Sealed? � 10d jar Sprinkler Deficiency Report A.S.A.P. SPRINKLER, LLC Customer Name: C4-ic, t516 6 PROGRESS AVE., UNIT#3 TYNGSBORO, MA 01879 Address 978-649-4945 _.A-��"A Fax: 978-649-9445 Telephone6 ��� L 2 66200 Contact-A-- SHIP DATE PURCHASE ORDER# SALES REPRESENTATIVE SHIP VIA TERMS TAX ID QTY. ITEM# DESCRIPTION UNIT PRICE TOTAL r• i P _. f r • � c;� 1�0� �e,e g 'tee. � vr.� Eb ;GYv12vl - COMMENTS: SUB TOTAL TAX IMPAIRMEN1' C=CRITIc44 MISCELLANEOUS __ ==oxen NC=NON CRITICAL R=RECOMMENDATION TOTAL On this date, the above equipment was maintained in accordance with the procedures of the adopted editions of the NFPA, authority having jurisdiction,and the manufacturer's manual.These;procedures were executed with the results indicated above. Service Technician tic. No. Date Time A.M. P.M. Customers Authorized Agent