Loading...
HomeMy WebLinkAboutCleaning and Inspection of Commercial Hood and Ventilation System - Inspection - 1268 OSGOOD STREET 2/2/2021 Boston Fire Department Cleaning and Inspection of Commercial Hood and Ventilation System & Deficiency Report Mass Hood Cleaning Inc 240 Columbus Ave Business Name; I 1�'I'LL I(c -1 Tech Name: Pawtucket,RI 02861 ddress: 24 Hour Emergency Service Phone Number Signature: A 3 \J City&Mate: (401) 648-1880 Date -7.. � ? Business Phone: BFD Reg C k-Exp bate Section A &e1ponses, Comments 1. Are the filters Clean? OYes n No n N/A 2. Are the precipitators/pollution control C]Yes n No Q N/A devices clean? 3. Is the grease load<2000 microns: a).horizontal Yes No b).vertical Yes No c).hood Yes No 4.Is the grease load in the fan<3175 [ZYes E] No microns? 5.Last service cleaning date? Co.Name: Not Available 6a.Is the on-site exhaust system diagram Yes No posted and accurate? 6b.Did you clean or inspect entire system as Yes No specified in on-sitc exhaust system diagram? If no specify on page 2. 7.1 las the Certificate of Performance been Yes No dated and placed in the immediate vicinity of the hood? I 8a.Are all filters in place and intact? U Yes No 8b.If Nvash system is main water valve in Yes No N/A open position? 9.Do fan(s)operate? _] a Yes M No 10. Have exhaust fan louvers been cleaned ®Yes M No N/A and checked? 11.Were exhaust fan(s)cleaned? MYes n No 12.Have exhaust fan belts and pulleys been I Yes FJ No inspected and in good working order? 13.Were grease cup(s)cleaned? ,e Yes n No 14.The system appears to be liquid tight? Yes F-1 No 15.1 las horizontal duct(s)been cleaned or 'Yes R No inspected? 16.1 las the vertical duct(s)been cleaned or RYes M No r-1 N/A inspected? 17 Are sufficient access panels provided? [Z[Yes [71 No [] N/A 18 Does access panel(s)have proper signage? Yes r_� No 19 Are all areas ofexhaust system QYes F-I No accessible? 20. Is hood and exhaust system free of Yes ❑ No obstructions? 21.Cleaning complied with NFPA 96, _ ny Yes n No 22.Type of cooking system(check all that Solid Fuel r-1 Wok apply) Charbroil Other(please specify): Owner Rep Name: /y) Date: r r Owner Re Signature: Any NO answer requires the deficiency report on page 2 to be completed and submitted as instructed on the bottom of page 2. N/A 7Not applicable A record of this service is to be maintained on premise and made available for inspection by a member of the Boston Fire Department,and Health or Building Inspectors from the City of Boston's Inspectional Services Department.It is the owner's/tenant's responsibility to maintain your equipment in good working order.It is the responsibility of the cleaning company technician to report all deficiencies immediately to the proper authority having jurisdiction