HomeMy WebLinkAboutSeptic Construction Notes - Consultant Review - 37 SCOTT CIRCLE 2/3/2022 North Andover Health Department
(ommunity and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 37 Scott Circle MAP: 105.D LOT: 69
INSTALLER: Peter Breen — 978-697-7092 permit # 64039 vp
DESIGNER: Michael O'Neill — 508-633-2311 septic plan submittal #62599 vp
PLAN DATE: 10-26-2021
BOH APPROVAL DATE ON PLAN: 11-16-2021
INSPECTIONS
TANK INSPECTION: 12/20/21 S. Casey
DATE OF BED BOTTOM INSPECTION: 12/14/21 S. Casey
DATE OF FINAL CONSTRUCTION INSPECTION: 12/29/21 D. Ottenheimer
DATE OF FINAL GRADE INSPECTION: o/. //. Aaaa. s, ra,se.y
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned, if
present
❑ Internal plumbing all to one building sewer
® Topography not appreciably altered
Comments: 12/29/21 — Existing tank remains to be abandoned. Could not access
basement to examine plumbing but it is a newer house and likely only has one
building sewer pipe existing. D. Ottenheimer
SEPTIC TANK
® Building sewer in continuous grade, on
compacted firm base
® Cleanouts per plan
® Bottom of tank hole has 6" stone base
® Tank size and loading per plan
® Monolithic tank construction
}
® If monolithic, water tightness of tank has been
achieved by visual testing
® Inlet tee installed, centered under access port
® Outlet tee installed, centered under access port
® Effluent filter installed
❑ If effluent filter, riser to finished grade over filter
❑ Riser with cover to within 6" of finish grade
installed over one access port
❑ Manhole and riser minimum inch diameter
® Pipe penetrations appear watertight using
rubber boots / hydraulic cement (circle one)
Comments: 12/20 — 6" stone noted across tank & pump chamber hole. Existing
tank still hooked up until new ones arrive.
12/29/21 — Building sewer has bend in it so a cleanout to grade was installed.
Pipe penetration into inlet side of septic tank is at a severe angle however it
appears watertight and was not requested to be fixed. Effluent filter selected is
not one proposed by designer. Manhole to finished grade over effluent filter to be
installed. D. Ottenheimer
PUMP CHAMBER
(Delete if not present) ® Bottom of tank hole has 6" stone base
❑ Weep hole plugged
® 1000 gallon Pump Chamber installed
® H-10loading
® Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
® Alarm float working
® Pump On/Off floats working
® Drain hole in pressure line
❑ _" cover at final grade installed over pump
access port
® Water tightness of tank has been achieved by
Visual testing
® Neoprene boots around inlet & outlet
Comments: 12/20 — OK, 6" stone noted
12/29/21 — Pump selected is per plan. Riser to finished grade over pump to be
installed
CONTROL PANEL
(Delete if not present) ❑ Alarm & Pump are on separate circuits
❑ Visual & audible alarm works as intended
® Location of control panel: Basement
Comments: 12/29/21 — Could not access basement but was able to hear audible
alarm, could not see if visual alarm but assumed to be present
DISTRIBUTION-BOX
❑ Installed on stable stone base
® H-20 D-Box
® Inlet tee (if pumped or >0.08'/foot)
® Hydraulic cement around inlet & outlets
® Even distribution observed
® Schedule 40 PVC Pipe
Comments: 12/29/21 —transition pipe from 2" to 4" installed for flow entering
distribution box. D. Ottenheimer
SOIL ABSORPTION SYSTEM (General)
® Bottom of SAS excavated down to specified
soil layer, as provided on plan
® Size of SAS excavated as per plan
® Sand installed, if specified on plan
® Sand displays few fines when handled
® 40 Mil HDPE barrier installed, if specified on
design plan
® Laterals installed and ends capped or
connected to header (and vented if impervious
material above)
❑ Retaining wall material, location and height if
specified on plan
Comments: 12/14/21 — 24' x 60' excavated, sand (one load) looks good. S.
Casey
12/29/21 — Contractor appears to have built trenches 2.5.'-3.0' wide instead of
2.0' as indicated on design plan thus the spacing between them is reduced. Not a
critical error which would trigger the removal and re-construction of the trenches
but note worthy enough to be documented herein. D. Ottenheimer
FINAL GRADE
Final cover as per plan
[� Loamed
Q` Seedej
Cover per plan
Comments:
DOCUMENTS NEEDED
Z( Certification of Installation Form submitted
by designer and signed and dated by
designer and installer
1011 As-Built Plan by designer
BM = 100.34
H R = 5.40
HI = 105.74
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT 3.85 101.56 101.60
Septic Tank IN 4.14 101.27 101.40
Septic Tank OUT 4.34 101.07 101.25
Pump Chamber IN 4.49 100.92 101.00
Pump Chamber OUT 2" 4.29 101.28 100.71
Distribution Box IN 2.82 102.59 102.52
Distribution Box OUT 2.98 102.43 102.35
Lateral 1 BEGINNING 3.13 102.28 102.25
Lateral 1 END 3.41 102.00 102.00
Lateral 2 BEGINNING 3.12 102.29 102.25
Lateral 2 END 3.41 102.00 102.00
Lateral 3 BEGINNING 3.13 102.28 102.25
Lateral 3 END 3.40 102.01 102.00
North Andover Health Department
Community and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 37 Scott Circle MAP: 105.D LOT: 69
INSTALLER: Peter Breen - 978-697-7092 permit # 64039 vp
DESIGNER: Michael O'Neill - 508-633-2311 septic plan submittal #62599 vp
PLAN DATE: 10-26-2021
BOH APPROVAL DATE ON PLAN: 11-16-2021
INSPECTIONS
TANK INSPECTION: `'
DATE OF BED BOTTOM INSPECTION.
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
IZf��� Building sewer in continuous grade, on
compacted firm base
cliv 1-"Kjkth Cleanouts per plan
Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Watertightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
Bottom of tank hole has 6" stone base
SL(L� ' ❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
❑ Installed on stable stone base
❑ H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
❑ Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTE (General)
2-W x bra` Bottom of SAS excavated down to C soil layer,
as provided on plan
— °�°� �` ��� Size of SAS excavated as per plan
r W
Title 5 sand installed, if specified on plan
❑ 40 Mil HDPE barrier installed
❑ Laterals installed and ends connected to
header (and vented if impervious material
above)
❑ Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments:
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
❑ Brand and Model of Chamber: Standard Quick
4 Infiltrator Chambers
❑ Number of chambers per row:
❑ Number of rows (trenches):
Comments: Total Chambers =
FINAL GRADE
[� Loamed ✓❑ i�'�y,.�d(���<<,�wex e-�c,w►6 �nite� o� � �
Seeded J
❑ Cover per plan M „I'.t-_40 V„X.&Xce P ( nil+° �lR�.pt�•I)
Comments: P-A L�'
1
DOCUMENTS NEEDED
❑ Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
❑ As-Built Plan
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
Distribution Box OUT
Lateral 1 TOP
Lateral 1 INVERT
Lateral 2 TOP
Lateral 2 INVERT
Lateral 3 TOP
Lateral 3 INVERT
Lateral 4 TOP
Lateral 4 INVERT
Lateral 5 TOP
Lateral 5 INVERT
Lateral 6 TOP
Lateral 6 INVERT
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
M Property line 10 10 --
M Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck, on footings, etc 5 10 --
M Waterline 10 10 101
M Private drinking well 75 1002 50
M Irrigation well 75 100
M Surface Water 25 50
M Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
M Trib.to surface water supply 325 325
M Public well 400 400
M Interim Wellhead Prot.Area
M Reservoirs 400 400
M Drains (wat. supply/trib.) 50 100
M Drains (intercept g.w.) 25 50
M Drains (Other)Foundation 10(5) 20(10)
M Drywells 20 25
Suction line 222(2)
z 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
s As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws
Peter Breen ExcIM20119,.Ine. Jq
Doper . -Baekhoe • Excavator • Trucking - Drainage -T 11 Z02
Septic . Stmnping - Fmi4h Grading • Yard 4 pcN pRT 2
New Lyaw= - Re-Seedm TN pFP,gRT N p pV
Mulch Stone • Gravel • Fill - Lown - Sand MFNT FR
Since 1972
sco
S� C-
C� v a �ar /l %�� �
JA - L
w � -2-
Ol ftfie n Blue- 6, rQS,5
�e-5 �
r/�G W � ��iL'�Z'v� L✓� �� �~ �� l/LCI. G '�
S
15 Lorraine Avenue - North Andover,MA OIW • (918)687-7774
'C\ Commonwealth of Massachusetts
City/Town of NORTH ANDOVER, MASSACHUSETTS
System Pumping Record
Form 4
DEP has provided this form for use by local Boards of Health. The System Pumping Record must n
be submitted to the local Board of Health or other approving authority. �F
A. Facility Information
Important:
When filling out 1. System Location:
forms on the
computer,use
only the tab key Address
to move your ` ) z, - ;t( L Z n1 't-
cursor-do not City/Town State Zip Code
use the return
key.
2. System Owner:
Nam
Address(if different from location)
City/Town State Zip Code
Telephone Number
B. Pumping Record
/,� -3
1. Date of Pumping Date � 2. Quantity Pumped: l °0
Ga ns
3. Type of system: ❑ Cesspool(s) Septic Tank ❑ Tight Tank
❑ Other(describe):
4. Effluent Tee Filter present? ❑ Yes �No If yes,was it cleaned? ❑ Yes ❑ No
5. Condition off/System: n
C �L K6 9 n/ n/MPILJ /
6. System Pumped By:
G j r"
Name Vehicle License Number
Company
7. Location where contents were disposed:
c�- ��-u.-f� y�✓ (��� mod- —3 4+J.'� I
Signature of Hauler Date
hftp://www.mass.gov/dep/Water/approvals/t5forms.htm#inspect
t5form4.doc•06/03 System Pumping Record•Page 1 of 1
No ov Masachu Stephen Casey <scaseY northandoverma. ov>
37 Scott Circle Septic Upgrade - Filter Type
3 messages
nks, Thanks Scoyy <mgoneill1@verizon.net> Wed, Jan 12, 2022 at 9:38 AM
Reply-To: "nks, Thanks Scoyy" <mgoneill1 @verizon.net>
To: "scasey@northandoverma.gov" <scasey@northandoverma.gov>
Hi Stephen
The septic tank filter that Peter Breen installed at the referenced location was a Zabel A1800 filter
which was the filter specified on the plan. See septic tank detail Sheet 2 of 2.
Michael
Stephen Casey<scasey@northandoverma.gov> Wed, Jan 12, 2022 at 10:16 AM
To: "nks, Thanks Scoyy"<mgoneill1@verizon.net>
Hi Michael,
Thank you for reaching out. Mill River noted that the filter observed during the final inspection at 37 Scott Circle was not a
Zabel A1800 filter but it was a Polylok-brand effluent filter instead. Is this Polylok filter acceptable in place of the Zabel
A1800 filter?
If you have any questions, please feel free to contact me.
Best,
Stephen
C: 978 807 0359
[Quoted text hidden]
Stephen Casey Jr.
Health Inspector
Town of North Andover
nks, Thanks Scoyy<mgoneill1@verizon.net> Wed, Jan 12, 2022 at 10:35 AM
Reply-To: "nks, Thanks Scoyy" <mgoneill1@verizon.net>
To: "scasey@northandoverma.gov" <scasey@ north andoverma.gov>
Yes to me it is. It is an equal to the Zabel.
Mike
[Quoted text hidden]