HomeMy WebLinkAboutACFrOgBCThyn3vzlHnohLuSCH3W1aJoJqAdZtBi...yi3puC4NpvjIiMINAlV-A9rteXVdP7Y_0= Lowell Central Electric C 0.1 1 n C. 182 Chelmsford Street, Lowell, MA 01851 (978) 453-7826 Annual Test Revort or: Market Basket Store #12 & Plaza 350 Winthrop Ave Andover, MA 01843 kw9compffig; December gth, 2021 FC1 FC-7200 Addressable Fire Alarm Control Panel PP N HRE CONTROL INSTRUMENTS 1'i1G t]IAilil IGJI UC, 11IJ.1G1.LlVli l\GtiUli Market Basket 412& Plaza 350 Winthrop Ave Andover,MA 01843 December 9th,2021 Site Contact: Store Manager Phone Number: 978-688-6322 Monitoring Entity: ADT AHJ: Andover Fire Department Contact Person: Central Station Operator Contact Person: Dispatch Phone Number: Store Manager Contacts Phone Number: 978-688-9590 Type Transmission: Sole Path Cell Account Number: Unknown Manufacturer: Star Link Model Number: Unknown Panel Manufacturer: FCI Model Number: FC-7200 Firmware Version: 4.30005 Firmware Revision Date: April 12", 1999 Number of SLC's: 2 Classification of sSLC's: A Circuits Supervised: Yes Survivability Level: 0 Number of NAC's: 2 Classification of NAC's: A Circuits Supervised: Yes Survivability Level; 0 System Alarm Initiating Devices and Circuit Information Quantity of Device Type Manufacturer/Model# Device 11 Manual Pull Station(Addressable) FCI MS-2 w/Mini-Module 2 Photo Electric Smoke Detector System Sensor 5 135 °Fixed Temp Heat Detector System Sensor 5 Photo Electric Duct Smoke Detector Not Listed 4 Sprinkler Waterflow Switch Potter 7 Sprinkler Tamper Switch Potter 1 Suppression System Ansul Alarm Indicating Appliances and Circuit Information Quantity of Circuit Class Device'Type Manufacturer/Model# Device 15 Class A Horn Strobe Gentex(Wheelock Retail) 4 Class A Strobe Only Gentex 3 Class A Exterior Beacon Micro Beacon Remote Annunciators Location Type Annunciator 1: By Market Basket Left Side Entrance Space Age LED Annunciator 2:NIA NIA Page 2 of 8 1'11G tL Lai I I J AGJt UC, I1V)PUkAJVll VICIJUlt Market Basket#12&Plaza 350 Winthrop Ave Andover,MA 01843 December 9th,2021 F.A.C.P. System Power Located in Courtesy Booth Primary Power Input Voltage: 120VAC Over Current Protection Type: Circuit Breaker Control Panel Amps: 6A Over Current Protection Size: 20A Location. Courtesy Booth,Panel: IG Circuit Number: 14 Batteries Nominal Voltage: 12VDC Type: Sealed Lead Acid Amp Hour Rating: ISAH Location: Inside FACP Number of Batteries: 2 Installation Date: December, 2021 In Standby Mode(Hours): 24 In Alarm Mode(Minutes): 5 Battery Test Voltage: (R)New,(L)New Battery Test Amp Hour: (R)New, (L)New FCI NAC-10A#1 System Power Located in Liquor Store Rear Storage Area Primary Power Input Voltage: 120VAC Over Current Protection Type: Circuit Breaker Control Panel Amps: 10A Over Current Protection Size: 20A Location: Panel PI Circuit Number: 6 Batteries Nominal Voltage: 12VDC Type: Sealed Lead Acid Amp Hour Rating: 12AH Location: Inside Booster Panel Number of Batteries: 2 Installation Date: November,2018 In Standby Mode(Hours): 24 In Alarm Mode(Minutes): 5 Battery Test Voltage: (R) 13.21VDC, (L) 13.24VDC Battery Test Amp Hour: (R) 100%, (L) 100% Notifications Made Prior to Testing Monitoring Organization Yes Contact: ADT Time: t2:00pm Building Management Yes Contact: Store Manager Time: 12:00pm Building Occupants Yes Contact: Store Manager Time: 12:00pm AHJ Yes Contact: Andover Fire Department Time: 12:00pin System placed in Test Mode on: Date, December 9"',2021 Time: 12:00pm System placed in Test Mode by: Store Manager Page 3 of 8 l ur tA[CIL 111 LGJ;U.. Ll lJ J)"t IV II IN Up VLl Market Basket#12& Plaza 350 Winthrop Ave Andover, MA 01843 December 9th,2021 System Test& Inspection Results Fire Alarm Control Panel Type Visual Functional Comments Test Test Control Unit Power Supple Control Unit X X Pass Latnps/LED's/LCD's X x Pass Fuses X X Pass Primary Power Supply X X Pass Secondary Power Supply -- - N/A Control Unit Equipment Trouble Signals X X Pass Disconnect Switclies X X Pass Ground Fault Monitoring X X Pass Panel Supervision X X Pass System Performance X X Pass Local Annunciator X X Pass Remote Annunciators X X Pass Isolation Modules -- - N/A Control Unit Batteries Battery Condition X X Pass Load Voltage X X Pass Discharge Test X X Pass Charger Test X X Pass Notification Appliances Audible Devices X X Pass Visual Devices X X Pass Dual Sync Module X X Pass Auxiliray Functions Door Releasing Devices -- N/A Fan Shutdown -- N/A FIVAC Shutdown Control X X Pass Smoke Management Control -- -- N/A Smoke Damper Operation -- -- N/A Smoke Shutter Release -- -- N/A Door Unlocking -- - N/A Elevator Recall -- -- Not Tested Elevator Shunt Trip -- - N/A Page 4 of 8 1' Ici r-.lallll IUM M 1IR!'Pr k1ull em;y It Market Basket 412& Plaza 350 Winthrop Ave Andover,MA 01843 December 9th,2021 System Test& Inspection Results NAC-10A#1 Panel Type Visual Test Functional Test Comments Control Unit X X OK Lamps/LED's/LCD's X X OK Fuses X X OK Primacy Power Supply X X OK Secondary Power Supply X X OK Ground Fault Monitoring X X OK Panel Supervision X X OK Battery Condition X X OK Load Voltage X X OK Discharge Test X X OK Charger Test X X OK Number of NAC's: 4 Classification of NAC's: A Circuits Supervised: Yes Survivability Level: I Aux Power In Use: Yes Tripped From: LIMO8 Initiating Alarm & Supervisory Device Test and Inspection Results As Captured by the F.A.C.P. N Andover Mall: ALARM: Manual Station ALU I L 1 M0 7 MARKET BASKET FRONT ENTRANCE OFFICE SIDE 13:29 12/09/21 N Andover Mall: ALARM: Manual Station ALUI L 1 MO MARKET BASKET FRONT ENTRANCE BAKERY SIDE 13:30 12/09/21 N Andover Mall: ALARM: Manual Station ALU1 LIM03 MARKET BASKET BAKERY EXIT DOOR 13:31 12/09/21 N Andover Mall: Page 5 of 8 1'11V ZA141 III LGb1[7- 1W.[JUGl1U111\GkJVII Market Basket-912 & Plaza 350 Winthrop Ave Andover, MA 01843 December 9th,2021 ALARM: Thermal Det ALUI L 1 S05 MARKET BASKET BAKERY COMPRESSOR ROOM 13:33 12/09/21 N Andover Mall: ALARM: Manual Station ALUI LIM06 MARKET BASKET RECEIVING EXIT DOOR 13:3712/09/2I N Andover Mall: ALARM: Manual Station ALUI LIM08 MARKET BASKET REAR EXIT BY ELECTRIC ROOM 13:39 12/09/21 N Andover Mall: ALARM: Photo Detector ALUI L I S28 MARKET BASKET LUNCH ROOM 13:46 12/09/21 N Andover Mall: ALARM: Manual Station ALU 1 L I M09 MARKET BASKET LUNCH ROOM 13:46 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI L1 S27 MARKET BASKET REAR MAIN RTU 13:47 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI L1 S26 MARKET BASKET FRONT MAIN RTU 13:48 12/09/21 N Andover Mall: ALARM: Thermal Det ALUI L 1 S31 MARKET BASKET MECHANICAL ROOM 13:48 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI L I S22 MARKET BASKET FRONT DAIRY RTU 6 13:50 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI L1 S21 MARKET BASKET FRONT CHECK OUT RTU 3 13:52 12/09/21 N Andover Mall: ALARM: Manual Station ALU 1 L I M 10 MARKET BASKET OFFICE Page 6 of 8 Market Basket#12&Plaza 350 Winthrop Ave Andover, MA 01843 December 9th,2021 13:53 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI LIS24 MARKET BASKET DELI RTU 4 13:54 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI L1 S25 MARKET BASKET REAR DAIRY RTU 7 13:55 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI LI S23 MARKET BASKET REAR CHECK OUT RTU 5 13:57 12/09/21 N Andover Mall: ALARM: Manual Station ALUI L2M22 OLYMPIA SPORTS SIDE EXIT 14:24 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALUI L2S20 OLYMPIA SPORTS H.V.A.0 14:25 12/09/21 N Andover Mall: ALARM: Manual Station ALU 1 L2M21 OLYMPIA SPORTS FRONT ENTRANCE 14:26 12/09/21 N Andover Mall: ALARM: Manual Station ALUI L2M11 LIQUOR STORE REAR EXIT 14:29 12/09/21 N Andover Mall: ALARM: Photo Duct Det ALU 1 L2S 10 LIQUOR STORE DUCT SMOKE 14:3 0 12/09/21 N Andover Mall: ALARM: Manual Station ALU 1 L2M09 LIQUOR STORE FRONT ENTRANCE 14:31 12/09/21 Page 7 of 8 1'11G tAltll 111 LGM M I t�,PCL,liull AGPUEI Market Basket#12& Plaza 350 Winthrop Ave Andover, MA 0 1843 December 9th,2021 On/Oft'Premises Monitoring: Alarm and Trouble signals were tripped to and received by ADT. All signals restored to normal condition. Notifications Made After Testing is Complete Monitoring Organization Yes Contact: Andover Fire Department Time: 3:00pm Building Management Yes Contact: Store Manager Time: 3:00pm Building Occupants Yes Contact: Customers Time: 3:00pm AHJ Yes Contact: Andover Fire Department Time: 3:00pm System placed in Test Mode on: Date: December, 9' 2021 Time: 3:00pm System placed in Test Mode by: Arthur Methot This Testing Was Done in Accordance with Applicable NFPA Standards: All Manual Pull Stations were operated. The Smoke Detectors were functionally tested by magnet. The Duct Smoke Detectors were tripped by remote test switch. The Roof Top Units shutdown according to proper correlation. The Horn Strobe circuits were operated. Notes: Replaced the batteries in the Main FACP Name of Inspector:Tony Barry Name of Inspector:Arthur Methot Organization: Lowell Central Electric Inc. Organization: Lowell Central Electric Inc. Date: December 9;h, 2021 Date: December 91h, 2021 Page 8 of 8