Loading...
HomeMy WebLinkAboutConstruction Notes - Rejected - Consultant Review - 544 JOHNSON STREET 6/16/2021 Sw�TLED �• • North Andover Health Department (ommunity and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 544 Johnson Street MAP: 38 LOT: 48 INSTALLER: James Morin 774-696-2246 DESIGNER: James Morin PLAN DATE: 03.13.2021 BOH APPROVAL DATE ON PLAN: 05.21.2021 Ie INSPECTIONS ' sa TANK INSPECTION: GA0 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on firm base ,/compacted Cleanouts per plan Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Watertightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX ❑ Installed on stable stone base ❑ H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) ❑ Hydraulic cement around inlet & outlets ❑ Observed even distribution ❑ Speed levelers provided (not required) ❑ Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) ^p q17; _ kM ' ❑ Bottom of SAS excavated down to C soil layer, as provided on plan 00 26"lI n0 ❑ Size of SAS excavated as per plan ql � ❑ Title 5 sand installed, if specified on plan ❑ 40 Mil HDPE barrier installed ❑ Laterals installed and ends connected to header (and vented if impervious material above) ❑ Elevations of laterals and chambers installed as on approved plan ❑ Retaining wall (boulder/ concrete / timber/ block) ❑ Final cover as per plan Comments: SOIL ABSORPTION SYSTEM (Gravel-less Chambers) ❑ Brand and Model of Chamber: Standard Quick 4 Infiltrator Chambers ❑ Number of chambers per row: ❑ Number of rows (trenches).- Comments: Total Chambers = FINAL GRADE ❑ Loamed ❑ Seeded ❑ Cover per plan Comments: DOCUMENTS NEEDED ❑ Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer ❑ As-Built Plan BM = HR = HI = SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT Septic Tank IN Septic Tank OUT Pump Chamber IN Pump Chamber OUT Distribution Box IN Distribution Box OUT Lateral 1 TOP Lateral 1 INVERT Lateral 2 TOP Lateral 2 INVERT Lateral 3 TOP Lateral 3 INVERT Lateral 4 TOP Lateral 4 INVERT Lateral 5 TOP Lateral 5 INVERT Lateral 6 TOP Lateral 6 INVERT Top of Chamber Bottom of Bed/Chamber SKETCH PLAN CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer ® Property line 10 10 -- ® Cellar wall 10 20 -- ® Inground pool 10 20 -- ® Slab foundation 10 10 -- ® Deck, on footings, etc 5 10 -- ® Waterline 10 10 10' ® Private drinking well 75 1002 50 ® Irrigation well 75 100 ® Surface Water 25 50 ® Bordering Vegetated Wetland , Salt Marsh, Inland/Coastal Bank3 75 100 ® Wetlands bordering surface water supply or trib. (in Watershed) 150 150 ® Trib.to surface water supply 325 325 ® Public well 400 400 ® Interim Wellhead Prot. Area ® Reservoirs 400 400 ® Drains (wat. supply/trib.) 50 100 ® Drains(intercept g.w.) 25 50 ® Drains(Other)Foundation 10(5) 20(10) ® Drywells 20 25 1 Suction line 222(2) 2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). 'As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA wetland bylaws Qa �� North Andover Health Department Community and Economic Development Division �n May 11, 2021 Michael Donnelly 544 Johnson Street North Andover, MA 01845 Re: Subsurface Sewage Disposal System Plan for 544 Johnson Street(Map 38,Lot 48) Dear Mr. Donnelly: The proposed wastewater system design plan for the above site with a final revision date of March 13,2021 has been approved. The design plan has been approved for usy in the construction of an upgrade on-site septic system for a 3-bedroom home utilizing a Cultec C4 Chamber system. The requested Title 5 variance to allow a 1' reduction from 4' to 3' of separation from the bottom of the soil absorption system to the estimated seasonal high water table has been granted. The design plan approval is valid until April 12,2023. During this time, a licensed septic system installer must obtain a permit and complete this work, and a Certificate of Compliance be endorsed by the installer, designer and the Town of North Andover. In the event an imminent health problem, such as sewage backup into the dwelling is occurring,the North Andover Board of Health may reduce the time period for which this plan is valid. This approval is also subject to the following conditions: 1. If site conditions are found in the field to be different from those indicated on the design plan and/or soil evaluation, the originally issued Disposal System Construction Permit is void, installation shall stop, and the applicant shall reapply for a new Disposal Systems Construction Permit(310 CMR 15.020(1)). Page 1 of 2 North Andover Health Department, Town Hall, 120 Main Street North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542 544 Johnson Street April 12, 2021 2. It is the responsibility of the applicant and/or the applicant's septic system designer, septic system installer or other representative to ensure that all other state and municipal requirements are met. These may include review by the Conservation Commission,Zoning Board, Planning Board, Building Inspector, Plumbing Inspector and/or Electrical Inspector. The issuance of a Disposal System Construction Permit shall not construe and/or imply compliance with any of the aforementioned requirements. Please feel free to contact the office with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely, Stephen Casey Public Health Inspector Encl. Installers list cc: James Morin, R.S. File Page 2 of 2 North Andover Health Department, Town Hall, 120 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542