734 Boxford st as built
2 messages
Stephen Casey <scasey@northandoverma.gov> Mon, Dec 20, 2021 at 12:31 PM
To: Benjamin Osgood <bosgoodpe@gmail.com>
Hi Ben,
Had a couple quick questions for you on the Boxford Street as built plan. I noted on the plans you specified that there
were 3 easements present, one for the water line and two for driveway and maintenance easement. I'm assuming the
water easement is for the Town, however do you have the owner(s)of the driveway& maintenance easement?
Another question I had was pertaining to the electrical service. Do you know if the electrical service was ran underground
to this property? I thought I remembered Kyle or Tom saying they had to dig a trench for this before finishing the loam &
seed but I want to make sure I am thinking of the correct property.
Thank you,
Stephen Casey Jr.
Health Inspector
Town of North Andover
Benjamin Osgood <bosgoodpe@gmail.com> Mon, Dec 20, 2021 at 12:52 PM
To: Stephen Casey<scasey@northandoverma.gov>
Hi Stephen,
The driveway and use easement is for the adjacent property. We showed
it as it appeared on the original design plan.
I am not sure where the electrical service is going, I don't think it
has been installed yet.
Ben
[Quoted text hidden]
>All email messages and attached content sent from and to this email account are public records unless qualified as an
exemption under the Massachusetts Public Records Law.
>Visit us online at www.northandoverma.gov.
NORTH ANDOVER
Massachusetts Toni Wolfenden <twolfenden@northandoverma.gov>
Final construction inspection - 734 Boxford Street
2 messages
Daniel Ottenheimer<dano@millriverconsulting.com> Tue, Nov 23, 2021 at 2:09 PM
To: 'Brian Lagrasse (blagrasse@ north andoverma.gov)" <baagrasse@northandoverma.gov>, Stephen Casey
<scasey@northandoverma.gov>, "Toni Wolfenden (twolfenden@northandoverma.gov)" <twolfenden@northandoverma.gov>
Brian, Steve, Toni-
All went well with the construction inspection at this address. The installer will need to put risers on one tank opening to
bring it to within 6" of finished grade and risers on the d-box as well might be needed. He will stay in touch with Steve
about this. No other items were noted.
Take care,
Dan
Daniel Ottenheimer, PE
President
as
ff MILL RIVER CONSULTING
Cttative Solutions for Lard Development
6 Sargent Street
Gloucester, MA 01930-2719
Phone: 978-282-0014 ext.802
www.millriverconsulting.com
i
Construction Notes -734 Boxford Street.doc
369K
Toni Wolfenden <tolfenden@northandoverma.gov> Tue, Nov 23, 2021 at 2:18 PM
To: Daniel Ottenheimer<dano@millriverconsulting.com>
Cc: "Brian Lagrasse (blagrasse@ north andoverma.gov)" <baagrasse@northandoverma.gov>, Stephen Casey
<scasey@northandoverma.gov>
Thank you!
Toni K. Wolfenden
Health Department Assistant
978-688-9540
Lo�cid:image002.jpg@01 CD02Al.85A49B40
[Quoted text hidden]
image001.jpg
4K
The-Morin-Cameron
GROUP, INC.
March 22, 2021 RECEIVED
Mr. Brian J. LaGrasse M '
Director of Public Health TOWN OF NORTH ANDOVER
120 Main Street HEALTH DEPARTMENT
North Andover, MA 01845
Re: Subsurface Sewage Disposal System Plan — Lot 9 - 0 Boxford Street (Map 105A, Lot 24)
Dear Brian:
We are in receipt of your review of the septic design for the above referenced property dated
March 4, 2021. On behalf of Peter Breen, The Morin-Cameron Group, Inc. has prepared the
following responses to your comments. Please find enclosed 3 sets of the revised Sanitary
Disposal System Design Plan for your review/approval. For convenience, the responses are
numbered in the same order and correlate to the numbered comments in your letter:
1. The plan view (Sheet 1 of 2) has been revised to show benchmarks within 50-75 feet of
the proposed facility.
2. The Distribution Box Detail shown (sheet 2 of 2) is designed to withstand H-20 loading.
3. Note 20 was added to the General Notes (sheet 1 of 2) to read "THE BUILDING SEWER
SHALL BE 4" PVC WITH WATERTIGHT JOINTS LAID ON A COMPACT BASE IN A STRAIGHT
LINE AT A CONTINUOUS GRADE WITH A MINIMUM SLOPE OF 1.0%".
4. Note 20 was added to the General Notes (sheet 1 of 2) to read "THE BUILDING SEWER
SHALL BE 4" PVC (SCH 40) PIPE WITH WATERTIGHT JOINTS LAID ON A COMPACT BASE
IN A STRAIGHT LINE AT A CONTINUOUS GRADE WITH A MINIMUM SLOPE OF 1.0%".
5. Note 2 was added to the Septic Tank Detail to show "ALL JOINTS, PENETRATIONS, AND
RISERS SHALL BE MADE WATERTIGHT(I.E.:TANK SHALL BE MADE WATERTIGHT)"and note
4 was added to the Distribution Box Detail to show "INLET AND OUTLET PIPE WALL
PENETRATIONS AND RISERS SHALL BE MADE WATERTIGHT" (sheet 2 of 2).
6. Note 3 was shown on the Enviro-Septic Leach Bed Detail (sheet 2 of 2) to show "THE TOP
OF THE LEACHING FACILITY SHALL BE LESS THAN 36" BELOW FINISH GRADE".
CIVIL ENGINEERS • LAND SURVEYORS • ENVIRONMENTAL CONSULTANTS • LAND USE PLANNERS
66 Elm Street, Danvers, MA 01923 978.777.8586 FAX 978.774.3488
Providing Professional Services Since 1978
www.morincameron.com
Mr. Brian LaGrasse March 22, 2021 Page 2
7. The soil evaluator has discussed the submitted soil testing forms with Mill River
Consulting. It has been agreed upon that the submitted forms are sufficient and DEP
forms 11 and 12 will not be required.
8. Note 4 was shown on the Enviro-Septic Leach Bed Detail (sheet 2 of 2) to show
"CONTRACTOR SHALL VERIFY THAT THE HIGH VENT THROUGH THE ROOF SUPPLIES
SUFFICIENT DRAFT. IF SUFFICIENT DRAFT IS NOT PRESENT, A HIGH VENT SHALL BE
ADDED AND VENTED THOUGH THE DISTRIBUTION BOX. A MINIMUM OF A 10,
DIFFERENTIAL IS REQUIRED BETWEEN THE HIGH VENT AND LOW VENT. NOTIFY DESIGN
ENGINEER IF HIGH VENT THROUGH DISTRIBUTION BOX IS REQUIRED".
9. Per the PRESBY Massachusetts Design and Installation manual the breakout elevation is
located at the bottom of the system sand as shown on the design plans.
We also made the following changes to the plans as requested in your letter:
1. The notes referring to the conventional system on the Plan View (sheet 1 of 2) and
Conventional Leaching Facility Design Data (sheet 2 of 2)were amended to include "(NOT
TO BE CONSTRUCTED)".
2. The note reference shown on the Enviro-Septic Leach Bed Detail was revised to refer to
General Note 18.
3. Notes were added to call out the locations of "System Sand" on the Enviro-Septic Leach
Bed Detail and System Profile (sheet 2 of 2).
We trust these responses address your comments/concerns. If you have any additional questions
please do not hesitate to contact our office.
Sincerely,
THE MORIN-CAMERON GROUP, INC.
\,e AA �� ~
John M. Morin, PE
Principal
JMM/kmm
Attachments
cc: Peter Breen
X:\Breen,Peter\684\Docs\Lot 9\Lot 9 BOH\Lot 9 Response Comments.docx
NORTH ANDOVER
Massachusets Toni Wolfenden <twolfenden@northandoverma.gov>
Revised plan review - 0 Boxford Street
Daniel Ottenheimer<dano@millriverconsulting.com> Thu, Mar 25, 2021 at 4:18 PM
To: "Brian Lagrasse (blagrasse@northandoverma.gov)"<baagrasse@northan dove rma.gov>, Stephen Casey
<scasey@northandoverma.gov>, "Toni Wolfenden (twolfenden@northandoverma.gov)" <twolfenden@northandoverma.gov>
Revised plan submitted for this location has addressed all open items and a suggested plan approval letter is attached for
your use.
Any questions, do let me know.
Dan
j46
b� 0,
Daniel Ottenheimer, PE
President
It
V MILL RIVER CONSULTING
C restive Sohaicn►s for Lid Development
6 Sargent Street
Gloucester, MA 01930-2719
Phone: 978-282-0014 ext.802
www.miliriverconsulting.com