HomeMy WebLinkAboutSeptic Approval Letter - Correspondence - 990 JOHNSON STREET 8/9/2022 North Andaver Health Department
(unmunity aural Ecaminunk Devetopnnneat, Divifiauru
Dan.Duu.ssaauult
9 ctti Johnson ta-eel.
Nun-(h A ncdo,ver, M A 0,184
ar�ra,aur~faaee 4enr� e Disposal Systein l!'ann. 9,90 Hlaafnnso n SO-eet JMap 107A.Lot Cd
Dear Mr. Dunssauunit:
The pa`unpur9secd annnsite Wastewater s sternz.design.pla n fi n°the a bc,°ve site dated 6/ 2/22 with ar li:nnaul
levisiaanu chute of 7'/30/22 has dneenn al p,rouYed d�.na•i�srnaan,n � cal°a Disposal l stem Construction
Permit(.D CP). Once issued, aan l:SCP will a auutliic:aaize the construction ofthe ornsite waustewwater
s ste nn per t e plan n&La`Lneed above and as arllunweul uurnder''I'itle 5, f the as,sa ehuasett
11' nvironnrentaal Cangle (310, CMR 15m00,0)„ You will need innvnnalvein enat liom the designer of the
oll"' le Nvansteww°aaten° System throughout the irnstaallaatacmn slnnnunld be square to coordinate
With.them.,
l"lru adesi 6,11 has been approved for use in the construct i o n cal"aura upgrade on site waastewarter"
sy!4eunn ffir as 3-bedroom haurnne utilizing the cxkfing septic Wilk. wi(h ar proposed effluent filter, the
existing punip tank and au standard 4()ne-4ncd- ipe soil. a bsorptiorn s sternn ,ats irnulicateal on the
design plat),
The ol)all 1br s sternn upgrades is to achieves full c,ornnlrliann ce with Aa to anncd ldacyadll aannsite wastewater
re,grulautivarns, l.rn this inustaannce full ca°nrn pl'irance '4w°us nncmt aac-,h evead because the design includes ;a.
reque.st fair a Lucaal Upgrade ppi,c:av�aal seeking to vary frerrnn the standards f fuull corn pl iaarice
This lcltter•S;ul, PCs tca cducon iernt: tlne endorsement of this,Loc t Upgrade Approval by the North
Andover Health Department.,
This design plain s,lalrro-vaal is valid liar 2 e:a'S Cro nn the above dame. During this tinrc, as licea a cd
septic s sten'l installer should obtain an permit and canmpletc this wwork, and as Certificate of
.................. ..... ......... ....
... ........................ .........
Page, f of
l"' n.armth Anndcaver ieanitia. l::telua�r°m.naruc gat.,ml aa�,wnu tda,all.,, 120 NMain Street
i^'u nµtln A nderc 'er, MA 0184 Pdudaaue� 9'7 .t:'m88,95 l0 f°a x: 97 .688. 9542
Compliance be ond,orsed by the installer, designer, and [he Town ofNorfll Andover. If thosc
activitics, are not Conipleted Within this thil,e period tbtm it i.,,; possible a ne"r desigii phm will necd
to be completed and submitted for rMew., In the event an iiimlinent health problein such as
Sewagc backup into the dwelling is occurring the Milt Andover Board of Heallb inayueclruo e the
Olne period R)r which this plait is valid.
This approval is subject to thefullowing Qoudi(ions, Plellse he cure to revie%v, these With tile
designer and installer.
Throughout (N-, project:
a.. Usi(e; conditions are fIOLAnd in the field to bc differcrit from those indicated on tine
desi gn plan, i iui tal I a 6 on o I'd i e oi i,wd le was tc wa le r syswi n s 111)a I I sto p, a nd tile
designer and this olli ce no fi.I ie'd wj fli in.24 hours,
ln. 'I'lic brand and model of eMuent filter specified on the design plan, is to be
Utilized. The instatler is, to denionstrate these have been made part o0he onsi(e
waNlewatei, systern
C. lvhulhole covers to, finished gyade are to be provided over tile cffluent filter and
punip, if not already present
d. If grouildwater,is, present. at flae bottom portion. of flle excavation fim- the soil,
absorption systull (SAS,) the excavation is to be dewatered prior to 11he pla.Qemen(
ol"any lit]. No fill is, to be placed for tile SAS duringrain or snow storins. Prior to
placeniient ofany needed fill In Itic SAS, the bettorn is, to be scarified and
relatively dry aud (lie fill ma(eri4l is to be stockpited Lit the edge of flic excavation
and filled, in graduall'y
e. Inspections are to be performed by the desigier of the (,nisite wastewater -sy-s-Lunl
as riceded to properly oversce and docuin.ent construction. Al as mininium
are the initial excavation, prior to backfilling, and durin backfilling well as
9
an y o therec)Mp(MCnt o f the co ns t ruction wBich the designer wishes to exa in i�ne
C Inspections are, to, be coiripleted by the Town of North Andover at a inininumi as
fbllomrs.
L Bed bottoin
ii. Tank bottoin
iii. Final installation of compolients, confirmation of propex., cum, jxmeTit
CXanlinatiorl of Construction methodology, and system opeu:011011
i V. Final gr4de
V. Sand fill will be.: Qojlede'd lions at feast one to arid arialyzed for
compliance with specifications in Title 5
g., No components, are to bc covered, until a final. component inspection has been
corn,pleted
h.. No,excavaOun ['or or work associrited with coristruclibn of tile soil absorption
systena is to a,fxurfroiii No,vemher 30 to, April I
Aftcr construction.
i, W it h,i n, 3 0 c�lays of complet ion of construction file: installer and designer are (o,
con firtm i I'the installation work was completed in conipliance with tile design plan
......................
..................................................................................
Page 2 of 3
North. Andover Health Depailment, Hall, 1.20 Maill slrk�,et'
North Aridover, MA 0 1845 PI'loile- 978AM540 Fax, 978688, 9542
referenced in the DS,CP and �vith Title 5,and if so shall ccilif� this on as
Certificate of Compliance Rm-m
If changes have been node to be appraved jdans then prep..ii.-WA),rt of an as-built
pdmi is req A red to,be� conap leted by the ciesi g,,en irm) changes have twen made
to, the approved plans then the aPpoved pimn shall be. rnodifiled' by the designer to,
s11(')%V the distances, froni a known �Arucktre 1:(,.) the system coniponctits.
k, No, sewage shall be dkellarged to the onsite wastewater SYSIC111 U116,11 as Ce�rtifiicate
of Conipliance ha,'., heeii issued by this office
In addidw; you should be aware oft e long-WITTI U�pe]-Wioll. gUidelillCS Of all OnSkC WaSteWa(er
system (11mve are not pailof the DSCT but are mentioned below as inforaiation 1"bir this property
Owner),
1. Ali onsite waste%wder systelai can fu,nction as an inWgm] part of tile infrastlUCtUrC 01"'
the Imoperty if itis propefly opermcd aml maintained. llii.sis that rcsi)orisibil�it)� of'(1i,t�
owner of the propciq,�y and is generAy not sptcificd by regulati(mi- You are
encouraged to contact as waste%vate.r syslern pUlnpmYAcr%'iCe provider to partner Willi
you lo, knplervient steps nio,eded to assure the longevity ofthe onsite wastewater
sp, Mern heiTag installed at this, location
2. T�he design plan specifies the w,'e ofan effluent filter hisicle the tank. This, component
is required to be exaninad aL least amumlly and cleaned as nank(l
TITC iSSUalliCe Ofa DSCP docs not 00111MI'Lte and/or imply compliance with any pen-nils, approvals
err licenses which might he needed fi-onij other agencies such as the (Amervation Commission,
Zordng Board, PhnMng Fkaki, Building 1nspector, Plunibirig Inspector and/or Dwrical
Inspector.
Mease feel Re to contact the: office with any questions you may have. We luok Kward to
ivorking with you to obtain as %vaslewater treatinelit and dispersal sy stern, which will. be ill
compliance Willi all regulations and assure protection ol'publiQ Ilealth and the cliviroluncrit ('A'
North. Andover-
Sincerely,
Steplichn Casey, Jh-.
IN= Health Inspector
Encl. Installers list
cc: Vladimir Nenichenok, P.E.
File
.............................. . .........---
Page 3 of 3
North Aticlover Health Departinem, Towia Hall,,, 120 N- lain St.re,,Ct,
Nor. [i An,)i:1o,%,1cr, NI.A. 0 l�845 Phone: 9"78.,68,8,,9,5,,!0 Fxx eta'8.688, 19542