Loading...
HomeMy WebLinkAboutSeptic Approval Letter - Correspondence - 24 FARNUM STREET 9/27/2022 North Andover Health Department Community and Economic Development Division September 27, 2022 Warren Sideri. 24 Farnum Street. North. Andover, MA 01845 Re: Subsurface Sewage ltis osal System Ilan for 24 Farnum Street(Map 10 7A Lot 24 Dear Mr. Side.ri: The proposed onsite wastewater system design plan for the above site dated 7/29/22 with a final revision elate of 9/22/2.2 has been approved for issuance of a:Disposal System ( onstruction Permit(I)SC I'). Once issued, a l)SCP will authorize the construction of the onsite wastewater system per the plan refarcnccd above and as allowed under'Title 5 of the Massachusetts F'nvironmental Code (31 Cl ("MR 15.000). You will need involvement frorn the designer of the onsite wastewater system throughout the installation process so you should be were to coordinate with them. The design has been approved f'or use in the construction of an upgrade on-site wastewater system for a 4-bedroorn (rnaximurrr 9-room) home utilizing the proposed septic tank with effluent filter in the septic tank, pump tank with pump and a standard stone-and-pipe soil absorption system as indicated on the design plan. This design plan approval is valid for 2 years from the above dale. During this time, a licensed septic system installer should obtain a permit and complete this work, and a Certificate of Compliance be endorsed by the installer, designer, and the Town of North Andover. If these activities are not completed within this time period then it is possible a new design plan will need. to be completed and submitted fear review. In the event;an inn-ninent health problem such as sewage backup into the dwelling is occurring the North Andover Board of"I lealtlr may reduce the tine period for which this plan is valid. Page 1 of 3 North Andover health Department, `fawn flail, 1.20 Main. Street North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542 This approval is subject to the 161lowing conditions. Please be sure to review these with the designer and installer. Prior to the issuance of Disposal System Construction permit.: a. The area of the proposed Soil Absorption System (SAS) is to be staked and flagged to identify the location(s) and to prevent activities which might damage the soil absorption system. Stockpiling of rilateriats and equipment within the SAS area is prohibited Throughout the project. a. If site conditions are hound in the -field to be different from those indicated oil the design plan, installation of the onsite wastewater system shall stop and the designer and this office notified within 24 hours b. The brand and model Of effluent. filter specified on the design plan is to be utilized. The installer is to demonstrate these have been made part of the onsite wastewater system. c. If groundwater is present at the bottom portion of the, excavation for the soil absorption system (SAS) the excavation is to be dewatered prior to the placement of any fill. No fill is to be placed for the SAS during rain or snow stornis. Prior to placement of any needed rill in the SAS, the bottom is to be scarified and relatively dry and the fill material is to be stockpiled at the edge of tile excavation and filled in gradually d. Inspections are to be performed by the designer of the onsite wastewater system as needed to properly oversee and document construction. At a jilininnini these are the initial excavation, prior to backfilling, and during backfilling as well as any other component of the construction which the designer wishes to examine e. Inspections are to be completed by the Town of North Andover at a minimum as follows: i. Bed bottom ii. Tank hottorn iii. Final installation ofcomponents, confirmation of'proper component selection, examination ofconstruction methodology, and system operation iv. Final grade v. Sand fill will be collected From at least orle location and analyzed far compliance with specifications in Title 5 f. No components are to be covered until a final component inspection has been completed g. No excavation for or work associated with construction of the soil absorption system is to occur from November 30 to April I After construction: h. Within 30 days Of completion of construction the installer and designer are to confirm if the installation work was completed in compliance with the design plan referenced in the DSCP and with Title 5, and if so shall certify this oil a Certificate of Compliance forin Page 2 of 3 North Andover Health Department, ']'own Hall. 120 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542 i. It'changes have been made to the appro\cd Plans then preparation ofan as-built plan is required to be completed by the designer. If no changes have been made to the approvcd plans then the approved plan shall be modified by the designer to show thc distances from a known StrLICtUrC, to the system components. j. No sewage shall be discharged to the onsitc wastewater sysletri until it Certificate of'Cornpliance has been issued by this off-ice In addition, you sliould be aware ofthe long-term operatiOn gUidelines ofan onsite wastewater system (these are nott part ofthe DS(T but arc mentioned below as information for the property Owner): I. An onsite wastewater sYstern can function as an integral part of the infrastructure of the propcily if it is properly operated and n ia.i ntai tied. This is the responsibility ofthe owner of the property and is generally not specified by regulation. You are encouraged to contact as wastewater systeni purriper/service provider to lxtrtner with YOU 10 implement steps needed to assure the IC)DgC\,ity of the onsite wastewater system being installed at this location 2. '1 fie design Plan specifies the use of an Cf`fIUCDt filter inside the tank. This component is recluircd to be examined at least annually and cleaned as needed The issuance ofa DSCP does not COnStRie and/or imply compliance with any Permits, approvals or licenses which might be needed from other agencies such as the Conservation ('ornmission, /oning Board, planning Board, Building Inspector, plumbing Inspector and/or Electrical Inspector. Please feel free to contact the office with any questions you may have. We look 6orward to working with you to obtain a wastewater Ireattrictit and dispersal system which will be in compliance with all regulations and assure protection ofliublic health and ilic, environment of North Andover, Sincerely, lZn J. LaGrasse, (TIJIT Director Ot'I'Liblic Flealth Fricl. Installers list cc: Vladimir Netuchenok, PA,- File Page 3 of3 North Andovcr 11calth Deparimcni, Town I lall. 120 Main Strect, North Andover, MA 0 1845 Phone: 978.688,9540 Fax: 978,688. 9542