HomeMy WebLinkAboutAs Built Comments Follow up - Correspondence - 851 JOHNSON STREET 7/26/2022 �i 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up NORTH ANDOVER Massachu,MS Stephen Casey<scasey@northandoverma.gov> 851 Johnson -As-built comments follow up 18 n cssages Will Schkuta<will@morincameron.com> Tue,Jul 26,2022 at 4:47 PM To:"Daniel Ottenheimer(dano@milldverconsulting.com)"<dano@milldverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@mori ncameron.com> Hi Dan, Hope all is well. I spoke with Mark Finn this afternoon and understand that you had a few comments during your final as-built field inspection. I received these comments second hand,so if they are not answered fully please let me know. 1.Comment regarding the holes in low point of the vent pipe. • This is standard practice for us on all septic designs and is also noted in the Presby manual. The holes allow for any condensation build up(not effluent)to drain from the vent pipe. If not present,condensation can build up and actually choke a system of air. Attached is the vent detail from the Presby manual that calls for holes to be drilled at the low point. 2.Comment regarding different benchmark. • When the survey crew was on site performing the layout for the field they observed that the tree with the benchmark along Mill Road was removed(evidence of old tree still in the wires). A new benchmark along Johnson Street was set by the crew in a tree near the leaching field(along Johnson Street)to make things easier for the installer. The benchmark behind the house still remains and was cross referenced to the new benchmark. 3.High vent supplying sufficient draft. • Based on discussions with the installer it is our understanding that the roof vent supplies sufficient draft. Per the Presby design manual,the roof vent will function as the high vent if there are no pumps,restrictions,or other vents between the low vent and the roof vent(See attached section of manual). The plumbing was inspected by the installer and no pumps,restrictions or other vents were observed. It is also our understanding that the interior plumbing was inspected and signed off by the town's plumbing inspector. Please advise if this all makes sense and it is ok to finish backfilling the system. Thanks, Will Schkuta, PE Senior Project Manager THE MORIN-CAMERON GROUP, INC. 66 Elm Street,Danvers,MA 01923 DANVERS,MA HAVERHILL,MA 66 Elm Street,Danvers,MA 01923 25 Kenoza Avenue,Haverhill,MA 01830 P:978-777-8586 P:978-373-0310 www.morincameron.com This communication,including attachments,is for the exclusive use of the addressee and may contain proprietary,confidential andlor privileged information.If you are not the intended recipient,any use, copying,disclosure,dissemination or distribution is strictly prohibited. If you are not the intended recipient please notify the sender immediately by return e-mail,delete this communication and destroy all copies. 18 doc02464020220726160637.pdf https://mail.google.co m/mail/u/0/?ik=fb80a9478f&view=pt&search=all&permthid=thread-fo/`3A1739449634145629478&simpl=msg-f`/o3Al 739449634... 1/21 r 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up 749K Daniel Ottenheimer<dano@millriverconsulting.com> Thu,Jul 28,2022 at 6:30 AM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@morincameron.com> Thanks Will. Items 2&3 make sense. Whenever a new benchmark appears the Town needs to know that it was established by the designer and not the installer,and if the engineer of record is ok with the venting of the EnviroSeptic system then it is not the Town's role to question that. Item 1 does not. The detail in the manual for the EnviroSeptic says the connecting pipe invert must be above the top of the d-box or highest EnviroSeptic line. Visually it did not appear that is the case at this site. Photo attached.Can you please confirm one way or the other? Dan Daniel Ottenheimer,PE President AV.:: ... tK MILL RIVER CONSULTING Orative Solutions for Lind Dm-clopment 6 Sargent Street Gloucester,MA 01930-2719 Phone:978-282-0014 ext.802 www.miliriverconsulting.com [Quoted text hidden] DSCN0643.JPG 973K Will Schkuta<will@morincameron.com> Thu,Jul 28,2022 at 12:18 PM To:Daniel Ottenheimer<dano@millriverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@morincameron.com> Hi Dan, https://mai l.google.com/mail/u/0/?i k=fb8Oa9478f&view=pt&search=al I&perrnth id=thread-f%3A1739449634145629478&si m pl=msg-f%3A1739449634... 2/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Thanks for the input. I will make sure we notify the town if a benchmark is replaced in the future. I reached out to Presby to review the vent as constructed. Dennis Fogg(Senior Technical Advisor)confirmed that the vent manifold as constructed is acceptable and conforms to the design standards of Presby. Attached is an email correspondence stating this. Can I let the installer know that all items noted at your inspection have been dealt with and the system can be backfilled? Please advise. Thanks, Will Schkuta, PE Senior Project Manager THE MORN-CAMERON GROUP, INC. P:978-777-8586 x205 [Quoted text hidden] ---------Forwarded message---------- From:Dennis Fogg<dfogg@presbyeco.com> To:Will Schkuta<will@morincameron.com> Cc: Bcc: Date:Thu,28 Jul 2022 16:04:47+0000 Subject:Re:851 Johnson Street,North Andover-Venting Design Compliance The manifold in the pictures you provided,meet our design standards for sloping beds. Dennis PE Dennis Fogg Senior Technical Advisor Phone:+1-603-837-9351 1 Mobile:+1-603-273-7729 143 Airport Road Whitefield,NH 03598 Website Facebook I YouTube Presby Environmental,Inc. From:Will Schkuta<will@morincameron.com> Sent:Thursday,July 28,2022 12:02 PM To:Dennis Fogg<dfogg@presbyeco.com> Subject:RE:851 Johnson Street, North Andover-Venting Design Compliance This email originated outside of IWT.Be cautious when opening any links or documents.If you have questions,contact ITSecurity@ads- pipe.com. Dennis, Can you please confirm that the vent manifold as constructed is acceptable to Presby and is conformance with the intent of the design manual based on your review of the photos and discussions we had? Thanks, Will Schkuta, PE Senior Project Manager https://mail.goog le.com/mai I/u/0/?ik=fb80a9478f&view=pt&search=al I&permth id=th read-f%3A1739449634145629478&simpl=msg-f%3A1739449634... 3/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up THE MORIN-CAMERON GROUP, INC. P:978-777-8586 x205 From:Dennis Fogg<dfogg@presbyeco.com> Sent:Thursday,July 28,2022 9:48 AM To:Will Schkuta<will@morincameron.com> Subject:Re:851 Johnson Street,North Andover-Venting Design Compliance Weep holes at the bottom of the vent manifold are commonly added to allow condensation to escape. This is detailed in our "Remote Venting"section of the manual. In the unlikely event wastewater enters the manifold (which is clearly sloped toward the rows), it would quickly clog the weep holes and be an indication the field is in distress. Normally the weep holes will never see anything but condensation. Hope that helps, Dennis Dennis Fogg PSenior Technical Advisor EI Phone:+1-603-837-9351 1 Mobile:+1-603-273-7729 143 Airport Road Whitefield,NH 03598 Presby Environmental,Inc. Website I Facebook I YouTube From:Will Schkuta<will@morincameron.com> Sent:Thursday,July 28,2022 9:23 AM To:Dennis Fogg<dfogg@presbyeco.com> Subject:851 Johnson Street,North Andover-Venting Design Compliance This email originated outside of IWT.Be cautious when opening any links or documents.If you have questions,contact ITSecudty@ads-pipe.com. Hi Dennis, Thank you for taking the time to discuss the constructed vent manifold for the Presby Enviro-Septic installation at 851 Johnson Street,North Andover(MA)this morning. As discussed,this leaching facility was designed as a serial distribution sloped system. A vent manifold was constructed coming off the end of each serial distribution set of Presby pipes(3 total). The vent manifold then runs down hill,where the vent then turns vertical at the edge of the sand fill. Since the vent manifold is going downhill,and has the potential to have condensation build at the low point we had the contractor drill a few holes in the low point(at the 90 deg elbow)and place crushed stone below in order to allow any condensation build up to drain from the vent line. Can you please confirm that the vent manifold as designed and installed(with holes drilled at low point)is acceptable and in conformance with the Presby design manual? I have attached a few photos of the vent manifold as constructed for reference. Thanks, Will Schkuta, PE Senior Project Manager THE MORIN-CAMERON GROUP, INC. 66 Elm Street,Danvers,MA 01923 https:Hmail.google.com/mail/u/0/?ik=fb80a9478f&view=pt&search=al l&permth id=thread-f%3A1739449634145629478&simpl=msg-f%3A1739449634... 4/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up DANVERS,MA HAVERHILL,MA 66 Elm Street,Danvers,MA 01923 25 Kenoza Avenue,Haverhill,MA 01830 P:978-777-8586 P.978-373-0310 www.modncameron.com This communication,including attachments,is for the exclusive use of the addressee and may contain proprietary,confidential ondlor privileged information.If you are not the intended recipient,any use, copying,disclosure,dissemination or distribution is strictly prohibited. If you are not the intended recipient,please notify the sender immediately by return e-mail,delete this communication and destroy all copies. NOTICE: This email message is intended only for the person or entity to which it is addressed. This email message,including any attachments,may contain confidential and/or privileged information and other materials,and is protected by copyright law. Any unauthorized review,use,disclosure,or distribution is strictly prohibited. If you are not the intended recipient,then please contact the sender by reply email and delete/destroy all copies of the original email message and any attachments. This email message,including any attachments,also may contain technical,or similar types of,information and materials. The sender does not make any express or implied representations or warranties with respect to such information and materials,including,without limitation,fitness for a particular purpose or merchantability or as to the accuracy or completeness of any such information and materials,and any such representations and warranties are hereby expressly disclaimed. P Y I NOTICE:This email message is intended only for the person or entity to which it is addressed.This email message,including any attachments,may contain confidential and/or privileged information and other materials,and is protected by copyright law.Any unauthorized review,use,disclosure,or distribution Is strictly prohibited.If you are not the intended recipient,then please contact the sender by reply email and delete/destroy all copies of the original email message and any attachments.This email message,including any attachments,also may contain technical,or similar types of,information and materials.The sender does not make any express or implied representations or warranties with respect to such information and materials,including,without limitation,fitness for a particular purpose or merchantability or as to the accuracy or completeness of any such information and materials,and any such representations and warranties are hereby expressly disclaimed. Re:851 Johnson Street,North Andover-Venting Design Compliance.eml 63K 9 j Daniel Ottenheimer<dano@millriverconsufting.com> Thu,Jul 28,2022 at 12:24 PM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverrna.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@modncameron.com> Please confirm if the connecting pipe invert is above the top of the d-box and all of enviro-septic lines per their manual,or not. If not,please provide a DEP approved design manual which authorizes this configuration or else modify what is in the field to comply with the DEP-approved Enviro-Septic manual. Thanks, [Quoted text hidden] Will Schkuta<will@morincameron.com> Fri,Jul 29,2022 at 4:08 PM To:Daniel Ottenheimer<dano@millriverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@morincameron.com> Dan, I spoke to Presby again and the installed vent for this system is NOT considered a remote vent. The vent is just a typical low vent with manifold. See attached correspondence from Presby confirming this is not a remote vent(as shown in the detail provided). I apologize for any confusion,but the intent of the detail I sent was to show that Presby does allow for holes to be drilled in the low point for condensation and not particularly to match what was installed. The vent for 851 Johnson is not detailed in the approved Presby manual. The technical advisor has confirmed this and has confirmed everything is in compliance with the design manual. https://mail.google.com/mail/u/0/?ik=fb80a9478f&view=pt&search=all&pelmthid=thread-fa/o3A1739449634145629478&simpl=msg-fa/o3A1739449634... - 5/21 1 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Please advise if the system can now be backfilled as is. The system has been opened for a while and we would like to get this backfilled as soon as possible. [Quoted text hidden) -----Forwarded message From:Dennis Fogg<dfogg@presbyeco.com> To:Will Schkuta<will@morincameron.com> Cc: Bcc: Date:Fri,29 Jul 2022 19:54:06+0000 Subject:Re:851 Johnson Street,North Andover-Venting Design Compliance We routinely have low vents on the downslope side of the field,even extending some distance from the field,but we haven't consider this a remote vent.Adding the weep holes at the lower vent elbow provides means for condensation to drain.We don't detail this very well in the manual.My apologies. Dennis Dennis Fogg Senior Technical Advisor Phone:+1-603-837-9351 1 Mobile:+1-603-273-7729 143 Airport Road Whitefield,NH 03598 Website 1 Facebook 1 YouTube Presby Environmental,Inc. From:Will Schkuta<will@modncameron.com> Sent:Friday,July 29,2022 2:42 PM To:Dennis Fogg<dfogg@presbyeco.com> Subject:RE:851 Johnson Street, North Andover-Venting Design Compliance This email originated outside of IWT.Be cautious when opening any links or documents.If you have questions,contact ITSecurity@ads- pipe.com. Hi Dennis, Thanks for taking time this afternoon to discuss the vent manifold again for this project. Per our discussion,the vent that was constructed for this is just a typical low vent connected with a vent manifold. It is NOT a remote vent that is depicted and detailed in the DEP Approved Enviro-Septic Design and Installation Manual. Therefore the connecting pipe inverts for this project DO NOT need to be above the highest point of the D-box and all of the ES lines. A detail for a typical low vent and vent manifold is not shown in the DEP approved design manual. The vent and vent manifold,as installed,is in full compliance with the approved design manual(i.e.vent manifold installed through offset adapters,4"vent line installed based on<1,000 linear footage of Presby Pipe,etc.). Can you please confirm these statements are accurate and based on the photos and discussions we had that the vent/vent manifold installed for this project is not a remote vent. The installed vent/vent manifold is a typical low vent/vent manifold that is not illustrated in the approved design manual? Appreciate the help and clarifications. Thanks, Will Schkuta, PE Senior Project Manager THE MORIN-CAMERON GROUP, INC. P:978-777-8S86 x205 From:Dennis Fogg<dfogg@presbyeco.com> Sent:Thursday,July 28,2022 12:05 PM To:Will Schkuta<will@modncameron.com> Subject:Re:851 Johnson Street,North Andover-Venting Design Compliance hftps://mai l.goog le.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=al l&permth id=thread-f°/u3Al 739449634145629478&simpl=msg-f%3A1739449634... 6/21 9120/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up The manifold in the pictures you provided, meet our design standards for sloping beds. Dennis Dennis Fogg PSenior Technical Advisor EI Phone:+1-603-837-9351 1 Mobile:+1-603-273-7729 143 Airport Road Whitefield,NH 03598 Presby Environmental,Inc. Website I Facebook I YouTube From:Will Schkuta<will@morincameron.com> Sent:Thursday,July 28,2022 12:02 PM To:Dennis Fogg<dfogg@presbyeco.com> Subject:RE:851 Johnson Street,North Andover-Venting Design Compliance This email originated outside of IWT.Be cautious when opening any links or documents.If you have questions,contact ITSecurity@ads-pipe.com. Dennis, Can you please confirm that the vent manifold as constructed is acceptable to Presby and is conformance with the intent of the design manual based on your review of the photos and discussions we had? Thanks, Will Schkuta, PE Senior Project Manager THE MORN-CAMERON GROUP, INC. P:978-777-8586 x205 From:Dennis Fogg<dfogg@presbyeco.com> Sent:Thursday,July 28,2022 9:48 AM To:Will Schkuta<will@morincameron.com> Subject:Re:851 Johnson Street,North Andover-Venting Design Compliance Weep holes at the bottom of the vent manifold are commonly added to allow condensation to escape. This is detailed in our "Remote Venting"section of the manual. In the unlikely event wastewater enters the manifold (which is clearly sloped toward the rows), it would quickly clog the weep holes and be an indication the field is in distress. Normally the weep holes will never see anything but condensation. Hope that helps, Dennis Dennis Fogg Senior Technical Advisor https://mai l.goog le.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=al l&permth id=thread-f%3A1739449634145629478&simpl=msg-f%3A1739449634... 7/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up PE E' Phone:+1-603-837-9351 1 Mobile:+1-603-273-7729 143 Airport Road Whitefield,NH 03598 Presby Environmental,Inc. Website I Facebook I YouTube From:Will Schkuta<will@modncameron.com> Sent:Thursday,July 28,2022 9:23 AM To:Dennis Fogg<dfogg@presbyeco.com> Subject:851 Johnson Street,North Andover-Venting Design Compliance This email originated outside of IWT.Be cautious when opening any links or documents.If you have questions,contact ITSecudty@ads-pipe.com. Hi Dennis, Thank you for taking the time to discuss the constructed vent manifold for the Presby Enviro-Septic installation at 851 Johnson Street,North Andover(MA)this morning. As discussed,this leaching facility was designed as a serial distribution sloped system. A vent manifold was constructed coming off the end of each serial distribution set of Presby pipes(3 total). The vent manifold then runs down hill,where the vent then turns vertical at the edge of the sand fill. Since the vent manifold is going downhill,and has the potential to have condensation build at the low point we had the contractor drill a few holes in the low point(at the 90 deg elbow)and place crushed stone below in order to allow any condensation build up to drain from the vent line. Can you please confirm that the vent manifold as designed and installed(with holes drilled at low point)is acceptable and in conformance with the Presby design manual? I have attached a few photos of the vent manifold as constructed for reference. Thanks, Will Schkuta, PE Senior Project Manager THE MORIN-CAMERON GROUP, INC. 66 Elm Street,Danvers,MA 01923 DANVERS,MA HAVERHILL,MA 66 Elm Street,Danvers,MA 01923 25 Kenoza Avenue,Haverhill,MA 01830 P:978-777-8S86 P:978-373-0310 www.morincameron.com This communication,including attachments,is for the exclusive use of the addressee and may contain proprietary,confidential and/or privileged information.If you are not the intended recipient any use, copying disclosure,dissemination or distribution is strictly prohibited. If you are not the intended recipient,please notify the sender immediately by return e-mail,delete this communication and destroy all copies. NOTICE: This email message is intended only for the person or entity to which it is addressed. This email message,including any attachments,may contain confidential and/or privileged information and other materials,and is protected by copyright law. Any unauthorized review,use,disclosure,or distribution is strictly prohibited. If you are not the intended recipient,then please contact the sender by reply email and delete/destroy all copies of the original email message and any attachments. This email message,including any attachments,also may contain technical,or similar types of,information and materials. The sender does not make any express or implied representations or warranties with respect to such information and materials,including,without limitation,fitness for a particular purpose or merchantability or as to the accuracy or completeness of any such information and materials,and any such representations and warranties are hereby expressly disclaimed. https://mai l.google.com/mail/u/0/?i k=fb8Oa9478f&view=pt&sea rch=all&permth id=thread-fa/o3AI 739449634145629478&si m pl=msg-fa/o3A1739449634... 8/21 9120/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up NOTICE: This email message is intended only for the person or entity to which it is addressed. This email message,including any attachments,may contain confidential and/or privileged Information and other materials,and is protected by copyright law. Any unauthorized review,use,disclosure,or distribution is strictly prohibited. If you are not the Intended recipient,then please contact the sender by reply email and delete/destroy all copies of the original email message and any attachments. This email message,including any attachments,also may contain technical,or similar types of,information and materials. The sender does not make any express or implied representations or warranties with respect to such information and materials,including,without limitation,fitness for a particular purpose or merchantability or as to the accuracy or completeness of any such information and materials,and any such representations and warranties are hereby expressly disclaimed. NOTICE:This email message is Intended only for the person or entity to which it is addressed.This email message,including any attachments,may contain confidential and/or privileged information and other materials,and is protected by copyright law.Any unauthorized review,use,disclosure,or distribution is strictly prohibited.If you are not the intended recipient,then please contact the sender by reply email and delete/destroy all copies of the original email message and any attachments.This email message,including any attachments,also may contain technical,or similar types of,information and materials.The sender does not make any express or implied representations or warranties with respect to such information and materials,including,without limitation,fitness for a particular purpose or merchantability or as to the accuracy or completeness of any such information and materials,and any such representations and warranties are hereby expressly disclaimed. Re:851 Johnson Street,North Andover-Venting Design Compliance.eml 87K Daniel Ottenheimer<dano@millriverconsulting.com> Mon,Aug 1,2022 at 2:29 PM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <joh n@morincameron.com> I am having trouble buying this as an acceptable solution. I do not see it depicted as such in the EnviroSeptic manual,and intuitively it simply makes little sense to allow a downgradient situation that could allow direct discharge of effluent in the event the EnviroSeptic system were to become clogged. Questions please: 1.Some of the images depict the vent on the uphill side of a sloping EnviroSeptic system and others show it on the downhill side. Could you move this vent to the uphill side and avoid the need to have any weep holes? Page 26 does not seem to indicate which side of the soil absorption system the vent is located. 2.This situation very much seems to be what is depicted in the image on page 27. As such this would need to comply despite your stating this is not a remote vent [Quoted text hidden] Will Schkuta<will@morincameron.com> Tue,Aug 2,2022 at 11:59 AM To:Daniel Ottenheimer<dano@milldverconsulbng.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@mori ncameron.com> Dan, I agree that the design manual is not completely clear and that it also seems to have contradictions. For example,the differential vent detail that shows a low vent does not illustrate the invert of the vent manifold above the Presby Pipe. Per my discussions with the alternative technology manufacturer's senior technical advisor,the venting situation that was constructed is NOT considered a remote vent and is not depicted in the approved manual. The technical advisor reviewed the photos and concurred that it is acceptable and compliant with the design manual for venting requirements. Venting a system down gradient is a common engineering practice that is utilized on Presby and other types of leaching facilities. It was also discussed with Presby that adding the weep holes in the vent line would not pose a direct discharge of effluent hazard. If the vent line was to see any effluent,the system would have to be in failure. If effluent did manage to get into the vent line,the few small weep holes would become clogged extremely fast. It should also be noted that the vent location is at the edge of system sand at an elevation well above the ESHWT. Evidence of breakout on the ground would most definitely be occurring at the same time and would pose a much larger health hazard. In response to your questions: 1.The vent is allowed to be on the uphill or downhill side of the system. Per our discussions with Presby,the vent is installed per the design manual and guidance of the manufacturer. We are request that it stays as is. 2.It is not a remote vent per the statements of the manufacturer. Per the technical advisor"We routinely have low vents on the downslope side of the field, even extending some distance from the field,but we haven't consider this a remote vent". Since it is not considered a remote vent,the remote vent detail https://mai l.google.com/mail/u/0/?i k=fb8Oa9478f&view=pt&sea rch=all&permth id=th read-f%3Al 739449634145629478&si m pl=msg-f%3A1739449634... 9/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up shown in the approval manual does not apply to this project. Please advise as this system is still open. [Quoted text hidden] Will Schkuta<will@morincameron.com> Tue,Aug 2,2022 at 12:19 PM To:"Daniel Ottenheimer(dano@millriverconsulting.com)"<dano@millriverconsulting.com> Cc:Stephen Casey<scasey@northan dove rma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@morincameron.com> Hi Dan, I apologize...I hit send on the previous email before finalizing. Please ignore previous email and see below. Will Schkuta, PE Senior Project Manager THE MORN-CAMERON GROUP, INC. P:978-777-8586 x205 From:Will Schkuta Sent:Tuesday,August 02,2022 12:00 PM To:Daniel Ottenheimer<dano@millriverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>;Mark Finn(markfinn.huntergroup@gmail.com)<markfinn.huntergroup@gmail.com>;John Morin <john@morincameron.com> Subject:RE:851 Johnson-As-built comments follow up Dan, I agree that the design manual is not completely clear and that it also seems to have contradictions. For example,the differential vent detail that shows a low vent does not illustrate the invert of the vent manifold above the Presby Pipe. DIFFERENTIAL VENTING (TYPICAL-NOT TO SCALE) HIGH VENT XA4 MIN.10, SUPPORT LOW VENT FINAL GRADE D-BOX https://mail.google.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=all&permthid=th read-f%3Al 739449634145629478&simpl=msg-f%3A1 73944963... 10/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up The detail showing the raised sloping system also does not show appropriate grading for the vent manifold if the manifold needed to be above the distribution box(if it was a remote vent),because the grading would need to be a minimum of 2"above the 1 St Presby Pipe. Raised sloping>10% WARO-SEPTIC LINES 1'MIN, V MIN. 15' TO INV.EL AT 15' LOW VENTISTING ' GROUNDINIMIMi COVER 7" SYSTEM SAND 3' 41 AT DEPTH OF W © LEVEL bQ TOPSOIL 31 CLEAN FILL ....:.":`::.. SURROUNDNG SE DISTANCE, - SAND IN OVERDIG AREA(TYPICAL) SYSTEM SAND ESFiOW PP I Y�C R SURROUNDING SAND YABOVE AND WDELOW RfS� 41q TE. (WHEN NEEDED) ENVIRO-SEPTIC LINES CLEAN FILL TRICTIVEF FREE OF STONES FAi(1gE AND BOULDERS>Ir Per my discussions with the alternative technology manufacturer's senior technical advisor,the venting situation that was constructed is NOT considered a remote vent and is not depicted in the approved manual. The technical advisor reviewed the photos and concurred that it is acceptable and compliant with the design manual for venting requirements. Venting a system down gradient is a common engineering practice that is utilized on Presby and other types of leaching facilities. It was also discussed with Presby that adding the weep holes in the vent line would not pose a direct discharge of effluent hazard. If the vent line was to see any effluent,the system would have to be in failure. If effluent did manage to get into the vent line,the few small weep holes would become clogged extremely fast. It should also be noted that the vent location is at the edge of system sand at an elevation well above the ESHWT. Evidence of breakout on the ground would most definitely be occurring at the same time and would pose a much larger health hazard. In response to your questions: 1.The vent is allowed to be on the uphill or downhill side of the system. Per our discussions with Presby,the vent is installed per the design manual and guidance of the manufacturer. We are request that it stays as is. 2.It is not a remote vent per the statements of the manufacturer. Per the technical advisor"We routinely have low vents on the downslope side of the field, even extending some distance from the field,but we haven't consider this a remote vent". Since it is not considered a remote vent,the remote vent detail shown in the approval manual does not apply to this project. Although the sloping vent detail shown on the approved plans is no longer shown in the MA design manual,it was confirmed with Presby that this construction detail is still valid. If we confirm that all the vent lines(3 total)are 6"above the connected Presby Pipe(so invert is 2"above Presby Pipe)and matches the detail on the approved plans will that be sufficient? If not we will have the contractor re-plump the vent line to be on the uphill side of the system if that will be sufficient for approval. Please advise as this system is still open. DISGUISE LOW VENT IN SHRUBS 2" MIN. OVER ENVIRO—SEPTIC tv PIPE FINAL GRADE sir; INLET TO D—BOX .GZ PLACE WASHED STONE C DISTRIBUTION BOX AROUND ELBOW ENVIRO—SEPTIC PIPE }1tGf1 GR ATER TABLE DRILL SEVERAL 1/4"o HOLES AT LOW POINT OF ELBOW TO DRAIN CONDENSATION, LOW POINT MUST BE ABOVE SEASONAL HIGH WATER TABLE. SLOPING VENT DETAIL (NOT TO SCALE) [Quoted text hidden) hftps:Hmail.google.com/mail/u/0/?ik=fb80a9478f&view=pt&search=all&permthid=thread-f%3Al73944963414562947'8&simpl=msg-f%3A173944963... 11/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Daniel Ottenhelmer<dano@millriverconsulting.com> Wed,Aug 3,2022 at 1:40 PM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmaii.com>,John Morin <john@morncameron.com> Mr.Morin is the engineer of record and Mr.Finn is trained and certified to install EnviroSeptic and thus they both know considerably more about this product than the Town does,so either approach you describe below is acceptable to the Town if it is acceptable to those two folks. From the Town's perspective we simply wish to eliminate the current condition which affords a possibility of effluent migrating into the holes that were drilled in the vent pipe. You all should decide which approach you will take to deal with that and stay in compliance with the product's use approval,and then let us know. Thanks. [Quoted text hidden] John Morin<john@morincameron.com> Thu,Aug 4,2022 at 5:41 PM To:Daniel Ottenheimer<dano@mi[iriverconsutting.com>,Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com> Hi Dan, We appreciate and understand your concern. We have designed several Presbys with the vent line designed in accordance with the Presby figure below with no issues. If the vent lines meet the criteria shown below(ie:the crown of the vent pipe is a minimum of 6 inches above the top of the Presby pipe)I will not have an issue signing off as it is in compliance with the Presby design documents. Thanks, DISGUISE LOW VENT IN SHRUBS 2' MIN. OVER ENVIRO-SEPTIC PIPE FINAL GRADE M INLET TO D-BOX i 0°E PLACE WASHED STONE DISTRIBUTION BOX AROUND ELBOW ENWRO-SEPTIC —� PIPE NIGH N A TABLE DRILL SEVERAL 1/4`9 HOLES AT LOW POINT OF ELBOW TO DRAIN CONDENSATION. LOW POINT MUST BE ABOVE SEASONAL HIGH WATER TABLE. SLOPING VENT DETAIL .NOT TO SCA'_=) John M. Morin, P.E. President THE MORIN-CAMERON GROUP, INC. 66 Elm Street,Danvers,MA 01923 DANVERS,MA HAVERHILL,MA https://mail.goog le.com/mai I/u/O/?ik=fb8Oa9478f&view=pt&search=al I&permth id=th read-f%3A1739449634145629478&si m pl=msg-f°/a3A173944963... 12/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up 66 Elm Street,Danvers,MA 01923 25 Kenoza Avenue,Haverhill,MA 01830 P:978-777-8586 P:978-373-0310 www.morincameron.com This communication,including attachments,is for the exclusive use of the addressee and may contain proprietary,confidential and/or privileged information.If you are not the intended recipient,any use, copying,disclosure,dissemination or distribution is strictly prohibited. If you are not the intended recipient,please notify the sender immediately by return e-mail,delete this communication and destroy all copies. [Quoted text hidden] Daniel Ottenheimer<dano@milldverconsulting.com> Fri,Aug 5,2022 at 8:45 AM To:John Morin<john@modncameron.com>,Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markftnn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com> Sounds good. What we were shown at the site did not have the upward bend in the pipe as depicted below(or perhaps it does exist and we just did not notice). [Quoted text hidden] John Morin<john@morincameron.com> Fri,Aug 5,2022 at 8:48 AM To:Daniel Ottenheimer<dano@milldverconsulting.com>,Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com> Hi Dan, We will be going out to verify and Mark will need to adjust if required. Thanks, [Quoted text hidden] Will Schkuta<will@morincameron.com> Tue,Aug 9,2022 at 3:46 PM To:Daniel Ottenheimer<dano@milldverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@morincameron.com> Dan, The vent manifold has been re-plumbed to ensure the invert of the vent manifold is a minimum of 2"above the crown of Presby Pipe(6"from crown of Presby Pipe to crown of 4"vent line). Attached are my level notes from this morning and some photos. I did run into Stephen this morning at another site and mentioned the adjustments...not sure if he was able to swing over to take a look. Please confirm that this system can now be 100%backfilled. [Quoted text hidden] 3 attachments 20220809_123110.jpg 6125K N4� 20220809_123116.jpg 6622K https://mail.google.com/mall/u/0/?i k=fb8Oa9478f&view=pt&search=all&permth id=th read-fa/a3Al 739449634145629478&simpl=msg-P/o3A173944963... 13/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up doc02481120220809150219.pdf 528K Daniel Ottenhe[mer<dano@milldverconsulting.com> Wed,Aug 10,2022 at 6:31 AM To:Stephen Casey<scasey@northandoverma.gov> Seems to me that tis configuration seems to comply with the product design manual and also eliminates the concern we had of effluent migrating into that elbow with the holes drilled in it and then out into the ground. I am fine with this if you are. [Quoted text hidden] 3 attachments x 20220809 123110.jpg I — 6125K 4 20220809_123116.jpg 6622K doc02481120220809150219.pdf 528K Stephen Casey<scasey@northandoverma.gov> Wed,Aug 10,2022 at 8:38 AM To:Daniel Ottenheimer<dano@millriverconsulting.com> I actually caught Will at another job site and went by afterwards and spoke to Mark on site.It looks good,I am all setl I'll give them the ok. [Quoted text hidden] Stephen Casey Jr. Health Inspector Town of North Andover Stephen Casey<scasey@northandoverma.gov> Wed,Aug 10,2022 at 8:39 AM To:Will Schkuta<will@morincameron.com> Cc:Daniel Ottenheimer<dano@millriverconsulting.com>,"Mark Finn(markfinn.huntergroup@gmail.com)"<markftnn.huntergroup@gmail.com>,John Morin <joh n@mori ncameron.com> Will, Thank you for the images and documentation.You are all set,I did get over there yesterday after we crossed paths on Abbott Street and I spoke with Mark on site.Mark can go ahead and backfill. Best, Steve [Quoted text hidden] [Quoted text hidden] Will Schkuta<will@morincameron.com> Wed,Aug 10,2022 at 8:40 AM To:Stephen Casey<scasey@northandoverma.gov> https:Hmail.goog le.com/mail/u/O/?ik=fb8Oa9478f&view=pt&search=all&permth id=th read-f%3A1739449634145629478&simpl=msg-f%3Al 73944963... 14/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Cc:Daniel Ottenheimer<dano@millriverconsulting.com>,"Mark Finn(ma,kfinn.huntergroup@gmail.com)"<markfinn.huntergroup@gmail.com>,John Morin <john@mori ncameron.com> Great. Thanks Steve! [Quoted text hidden] All email messages and attached content sent from and to this email account are public records unless qualified as an exemption under the Massachusetts Public Records Law. Visit us online at www.northandoverma.gov. mark finn<markfinn.huntergroup@gmail.com> Wed,Aug 10,2022 at 9:39 AM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>,Daniel Ottenheimer<dano@milldverconsulting.com>,John Morin<john@morincameron.com> Thanks Steven.will do.catch you on the next one.Best,Mark Sent from my!Phone On Aug 10,2022,at 8:40 AM,Will Schkuta<will@morincameron.com>wrote: [Quoted text hidden] [Quoted text hidden] [Quoted text hidden] Daniel Ottenheimer,PE President t MILL RIVER CONSULTING (:rnative Soluunus lirr l:uni lkwnlnpmrnt 6 Sargent Street Gloucester,MA 01930-2719 Phone:978-282-0014 ext.802 i I www.millriverconsulting.com I i i From:John Morin<john@morincameron.com> Sent:Thursday,August 4,2022 5:41 PM To:Daniel Ottenheimer<dano@millriverconsulting.com>;Will Schkuta<will@morncameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>;Mark Finn(markfinn.huntergroup@gmail.com)<markfinn.huntergroup@gmail.com> Subject:RE:851 Johnson-As-buik comments follow up i Hi Dan, We appreciate and understand your concern. We have designed several Presbys with the vent line designed in accordance with the Presby figure below with no issues. If the vent lines meet the criteria shown below(ie:the crown of the vent pipe is a minimum of 6 inches above the top of the Presby pipe)I will not have an issue signing off as it is in compliance with the Presby design documents. https:Hmail.goog le.com/mai I/u/0/?ik=fb80a9478f&view=pt&search-al I&permth id=th read-f%3Al 739449634145629478&sim pl=msg-f%3A173944963... 15/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Thanks, DISGUISE LOW VENT IN SHRUBS 2' MIN. OVER ENVIRO-SEPTIC PIPE FINAL GRADE y� 3 INLET TO D-BOX 0"E PLACE WASHED STONE DISTRIBUTION BOX AROUND ELBOW ENVIRO-SEPTIC PIPE HIGH A R TABLE ---DRILL SEVERAL 1/4.0 HOLES AT LOW POINT OF ELBOW TO DRAIN CONDENSATION. LOW POINT MUST BE ABOVE SEASONAL HIGH WATER TABLE. SLOPING VENT DETAIL (NDT TO SCALE) John M. Morin, P.E. President THE MORIN-CAMERON GROUP, INC. 66 Elm Street,Danvers,MA 01923 DANVERS,MA HAVERHILL,MA 66 Elm Street,Danvers,MA 01923 25 Kenoza Avenue,Haverhill,MA 01830 P:978-777-8586 P:978-373-0310 www.morincarneron.com This communication,including attachments,is for the exclusive use of the addressee and may contain proprietary,confidential and/or privileged information.1 f you are not the intended recipient,any use,copying,disclosure,dissemination or distribution is strictly prohibited. If you are not the intended recipient,please notify the sender immediately by return e-mait delete this communication and destroy all copies. From:Daniel Ottenheimer<dano@millriverconsulting.com> Sent:Wednesday,August 3,2022 1:40 PM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandoverma.gov>;Mark Finn(markfinn.huntergroup@gmail.com)<markfinn.huntergroup@gmail.com>;John Morin<john@morincameron.com> Subject:RE:851 Johnson-As-built comments follow up Mr.Morin is the engineer of record and Mr.Finn is trained and certified to install EnviroSeptic and thus they both know considerably more about this product than the Town does,so either approach you describe below is acceptable to the Town if it is acceptable to those two folks. From the Town's perspective we simply wish to eliminate the current condition which affords a possibility of effluent migrating into the holes that were drilled in the vent pipe. You all should decide which approach you will take to deal with that and stay in compliance with the product's use https://mai l.goog le.com/mail/u/O/?ik=fb8Oag478f&view=pt&search=all&permth id=th read-fo/a3AI 739449634145629478&sim pl=msg-f%3A173944963... 16/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up approval,and then let us know. i Thanks. I ' Dan i Daniel Ottenheimer,PE President i ata: t[ MILL RIVER CONSULTING Carative&)lutiam for tattd Development 6 Sargent Street Gloucester,MA 01930-2719 Phone:978-282-0014 ext.802 j www.millriverconsulbng.com i ; From:Will Schkuta<will@modncameron.com> Sent:Tuesday,August 2,2022 12:19 PM ` To:Daniel Ottenheimer<dano@millriverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>;Mark Finn(markfinn.huntergroup@gmail.com)<markfinn.huntergroup@gmail.com>;John Morin<john@modncameron.com> Subject:RE:851 Johnson-As-built comments follow up Hi Dan, I apologize...I hit send on the previous email before finalizing. Please ignore previous email and see below. Will Schkuta, PE Senior Project Manager THE MORIN—CAMERON GROUP, INC. P:978-777-8586 x205 From:Will Schkuta Sent:Tuesday,August 02,2022 12:00 PM To:Daniel Ottenheimer<dano@millriverconsulting.com> Cc:Stephen Casey<scasey@northandoverma.gov>;Mark Finn(markfinn.huntergroup@gmail.com)<markfinn.huntergroup@gmail.com>;John hftps://mail.google.com/mai I/u/0/?ik=fb8Oa9478f&view=pt&search=all&permth id=thread-f%3Al 739449634145629478&simpl=msg-f%3A173944963... 17/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Morin<john@morincameron.com> Subject:RE:851 Johnson-As-built comments follow up I Dan, I agree that the design manual is not completely clear and that it also seems to have contradictions. For example,the differential vent detail that shows a low vent does not illustrate the invert of the vent manifold above the Presby Pipe. DIFFERENTIAL VENTING (TYPICAL-NOT TO SCALE) HIGH VENT M IN. 10' SUPPORT LOW VENT FINAL GRADE D-BOX The detail showing the raised sloping system also does not show appropriate grading for the vent manifold if the manifold needed to be above the distribution box(if it was a remote vent),because the grading would need to be a minimum of 2"above the 1 st Presby Pipe. Raised sloping >10% ENVIRO-SEPTIC LINES 1'MIN. V MIN. 15' TO INV.EL AT 15''� LOW VENT /EXISIING IINIMUM COVERT SYSTEM SANU X GROUND 4.1 AT DEPTH OF W ,_�._„_,r.-• ::ty;i ;xx © © LEVEL CLEAN FILL 6EPARAT DISTANCE, ` .•+•" :." SURROUNDING SAND IN OVERDIG _ ESHGW TU AREA(TYPICAL) SYSTEM SANG pE�lal 'VUAOCCM ' SURROUNDING SAND- W ADOVE AND O BELOW CLEAN FILL RESTRTC7yyEFWt (WHFN NFFDFO) ENVIROSEPTIC LINES FREE OF STONES EA7'URE AND BOULDERS>8' i i i Per my discussions with the aftemative technology manufacturer's senior technical advisor,the venting situation that was constructed is NOT considered a remote vent and is not depicted in the approved manual. The technical advisor reviewed the photos and concurred that it is acceptable and compliant with the design manual for venting requirements. Venting a system down gradient is a common engineering practice that is utilized on Presby and other types of leaching facilities. It was also discussed with Presby that adding the weep holes in the vent line would not pose a direct discharge of effluent hazard. if the vent line was to see any effluent,the system would have to be in failure. If effluent did manage to get into the vent line,the few small weep holes would become clogged extremely fast. It should also be noted that the vent location is at the edge of system sand at an elevation well above the ESHWT. Evidence of breakout on the ground would most definitely be occurring at the same time and would pose a much larger health hazard. In response to your questions: i https://mai l.goog le.com/mail/u/0/?i k=fb8Oa9478f&view=pt&search=all&permth id=th read-f°/u3A l 739449634145629478&si m pl=msg-f%3A173944963... 18121 i i 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up 1.The vent is allowed to be on the uphill or downhill side of the system. Per our discussions with Presby,the vent is installed per the design manual and guidance of the manufacturer. We are request that it stays as is. 2.It is not a remote vent per the statements of the manufacturer. Per the technical advisor"We routinely have low vents on the downslope side of the field,even extending some distance from the field,but we haven't consider this a remote vent". Since it is not considered a remote vent,the remote vent detail shown in the approval manual does not apply to this project. I Although the sloping vent detail shown on the approved plans is no longer shown in the MA design manual,it was confirmed with Presby that this construction detail is still valid. If we confirm that all the vent lines(3 total)are 6"above the connected Presby Pipe(so invert is 2"above Presby Pipe)and matches the detail on the approved plans will that be sufficient? If not we will have the contractor re-plump the vent line to be on the uphill side of the system if that will be sufficient for approval. Please advise as this system is still open. DISGUISE LOW VENT IN SHRUBS 2' MIN. OVER EN ARO-SEPTIC PIPE FINAL GRADE hz J 51�F INLET TO D-BOX PLACE WASHED STONE DISTRIBUTION BOX AROUND ELBOW ENVIRO-SEPTIC PIPE ��GR ATER TABLE DRILL SEVERAL 1/4"0 HOLES AT LOW POINT Of ELBOW TO DRAIN CONDENSATION, LOW POINT MUST BE ABOVE SEASONAL HIGH WATER TABLE. SLOPING VENT DETAIL (NOT TO SCALE) i Thanks, Will Schkuta, PE Senior Project Manager THE MORN-CAMERON GROUP, INC. P:978-777-8586 x205 From:Daniel Ottenheimer<dano@milldverconsulting.com> Sent:Monday,August 01,2022 2:29 PM To:Will Schkuta<will@morincameron.com> Cc:Stephen Casey<scasey@northandovenna.gov>;Mark Finn(markfinn.huntergroup@gmail.com)<markfinn.huntergroup@gmail.com>;John Morin<john@modncameron.com> Subject:RE:851 Johnson-As-built comments follow up I am having trouble buying this as an acceptable solution. I do not see it depicted as such in the EnviroSeptic manual,and intuitively it simply makes little sense to allow a downgradient situation that could allow direct discharge of effluent in the event the EnviroSeptic system were to become clogged. Questions please: 1.Some of the images depict the vent on the uphill side of a sloping EnviroSeptic system and others show it on the downhill side. Could you move this vent to the uphill side and avoid the need to have any weep holes? Page 26 does not seem to indicate which side of the soil absorption system the vent is located. 2.This situation very much seems to be what is depicted in the image on page 27. As such this would need to comply despite your stating this is not a remote vent https://mai l.google.com/mail/u/0/?ik--fb80a9478f&view=pt&search=al I&permth id=th read-f%3A1739449634145629478&simpl=msg-f%3A173944963... 19/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up Dan Daniel Ottenheimer,PE President q1Q!rMILL RIVER CONSULTING Orativc Sahuious for Lund I X-velopmcrn [Quoted text hidden] [Quoted text hidden] Daniel Ottenheimer,PE President '[ MILL RIVER CONSULTING Ctearive 5olutium fin Luid DLvAoptnctu [Quoted text hidden] [Quoted text hidden] Daniel Ottenheimer,PE President qK.'S MILL RIVER CONSULTING creative Solutions hn Land I)mclopmcut [Quoted text hidden] [Quoted text hidden] [Quoted text hidden] 4 attachments image001.png https://mai l.goog le.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=al I&permth id=thread-f%3A1739449634145629478&simpl=msg-f%3AI 73944963... 20/21 9/20/22,4:28 PM Town of North Andover Mail-851 Johnson-As-built comments follow up 20K MILL RIVER CONSULTING Caeative&Autious for Lmd Development O MILL RIVER CONSULTING 20K Qr.16ve&yhttions for Lvtd Development r� r: f� image001.png MILL RIVER CONSULTING 20K Creative Sohttions feu Lutd Development Asa image001.png t(MILL RIVER CONSULTING 20K C wative&lutions for Laid Dmelopment https:Hmail.google.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=all&permthid=thread-f%3Al739449634145629478&simpl=msg-f%3A173944963... 21/21 Section J Venting Requirements General rule Low and high vents are required of all systems to ensure that air is drawn completely through the entire ES system. No additional vents may be located between the high vent and low vent. The opening of the high vent must be at least 10 feet above the opening of the low vent. High vents must provide at least the same flow capacity as low vents. Connections within the system must also have similar flow capacities. Purpose: Venting design,installation,and maintenance must ensure that every linear foot of ES pipe in all serial beds,sections,or lines receives oxygen to accommodate natural biologic activity. Low vent Low vents are installed through an offset adapter at the end of each locations • serial system or bed • section of a combination system • line of a distribution box system. High vent High vents are installed in a variety of locations based on the system design. locations • The roof vent will function as the high vent if there are no pumps, restrictions,or other vents between the low vent and the roof vent. • If a restriction is placed between the low vent and the roof vent,a high vent is required through an unused distribution box outlet. • In pumped systems a high vent is required through an unused distribution box outlet. High vent on This diagram shows a high vent installed in a D-box. This configuration is required in pumped D-box systems or when other restrictions or vents are installed between the low vent and the roof vent. DIFFERENTIAL VENTING (TYPICAL-NOT TO SCALE) HIGH VENT MIN.110, SUPPORT LOW VENT FINAL GRADE D-BOX Continued ©Presby Environmental, Inc., Massachusetts Enviro-Septic®D&I Manual,September 2019 Edition -26- Venting Requirements, Continued Vent manifolds A vent manifold can be incorporated to connect the ends of a number of sections or lines of ES pipe to a single vent opening. One 4 in vent is required for every 1,000 ft.of pipe. A 6 in. manifold and vent stack may vent up to 3,000 ft.of pipe. o LL_ LU LU U) InIL } F WW Z F N O Z > O fQ- � � O z ~ m y Ill LL O to O U p x Ox a Remote vent Remote vent piping should slope piping slope downward toward the system to prevent moisture from collecting in REMOTE VEN the piping and blocking air passage. If site conditions do not D-BOX OR END OF allow the pipe to the vent to slope SERIAL BED,SECTION OR LINE LL HOES AT LOW PIN back toward the system,the low ;CONNECTING NLCONDEN ATION T point of the connecting pipe FINAL GRADE should be drilled to allow drainage provided that the connecting pipe invert is above the highest point of the D-box and all of the ES lines. PIPE INVERT MUST BE ABOVE TOP OF D-BOX OR HIGHEST ENVIRO-SEPTIC LINE By-Pass By-Pass venting is used to eliminate the need for a High vent at the field and can also replace Venting the need for a pump chamber vent.There must be at least 10 ft.of elevation between the roof stack and low vent openings. 11 WHEN USING BY-PASS VENTING THE ROOF VENT I I REPLACES THE'HIGH'VENT AND PUMP CHAMBER II VENT(IF REAM).THE OPENING OF ROOF VENT MUST 11 BE AT LEAST 10 FT.ABOVE OPENING OF LOW VENT I1 11 II 10'MIN II I 11 BY-PASS VENTING REPLACES BOTH 11 THEHIGH VENT ANDPUMPCHAMBER IIw LOWVENTISAIR ;NT(IF REQUIRED) INTAKE 11� 11 IlU1 3• ATTACH BY-PASS VENT TO I I FINISH GRADE PUMP CHAMBER ORUNUSED ----------- -� OPENING IN SEPTIC TANK II ' SNE� PRESSY FIELD-- I P I •..NO EFFLUFJIT, ' .•FLYER;;: NOTES: 1.NOT TO BE USED WITH GRAVITY SYSTEMS. SEPTIC TANKWITH PUMP SANITARY TEE BAFFLES CHAMBER Y.INVERT OF PIPE EXITING"OX MUST RISE 2-MINIMUM ABOVE 0-BOX. OPTIONAL CONFIGURATION 3.USE 4-SCH.40 PVC OR EQUAL FOR BY-PASS PUMP CHAMBER BY-PASS (IF EFFLUENT FILTER USEDI VENTING. VENT HIGH ER Tgo T 'A TOO-BOX BABOVETOP 4.GLUE ALL PVC JOINTS OR EQUAL SEPTICTANK NK O O O O I JW6 VIEW A-A PUMPBOX (ROTATED 80') A ADD PUMP CHAMBER BY-PASS VENT IF EFFLUENT FILTER IS USED ON SEPTIC TANK OUTLET BAFFLE ©Presby Environmental, Inc., Massachusetts Enviro-Septic®D&I Manual, September 2019 Edition -27- 9/20/22,4:28 PM OSCN0643.JPG t r ,r r e �y' tr m ar'F• .. y . r 3 3 a 5 https://mail.google.com/mail/u/0/?tab=rm 1#search/851+johnson/FMfcgzGpHHPncgpgktKglHrcPFwBbKdL?compose=GTvVicRwPVIMRnMSWkHvrsbp... 1/1 9/20/22,4:28 PM Re:851 Johnson Street,North Andover-Venting Design Compliance-scasey@northandoverma.gov Subject: Re: 851 Johnson Street, North Andover - Venting Design Complia ? Dennis Fogg <dfogg@presbyeco.com> to Will Schkuta You are viewing an attached message. Town of North Andover Mail can't verify the authenticity of attached mE We routinely have low vents on the downslope side of the field, even extending some distance from haven't consider this a remote vent. Adding the weep holes at the lower vent elbow provides means to drain. We don't detail this very well in the manual. My apologies. Dennis PE Dennis Fogg Senior Technical Advisor Phone: +1-603-837-9351 1 Mobile: +1-603-273-7729 143 Airport Road Whitefield,NH 03598 Website I Facebook I YouTube Presby Environmental,Inc. From:Will Schkuta <will morincameron.com> Sent: Friday,July 29, 2022 2:42 PM To: Dennis Fogg<dfogg@presbyeco.com> Subject: RE: 851 Johnson Street, North Andover-Venting Design Compliance This email originated outside of IWT. Be cautious when opening any links or documents. If you have questions, cc ITSecurity_@ads-pipe.com. Hi Dennis, Thanks for taking time this afternoon to discuss the vent manifold again for this project. Per our discussion, the vE constructed for this is just a typical low vent connected with a vent manifold. It is NOT a remote vent that is depict the DEP Approved Enviro-Septic Design and Installation Manual. Therefore the connecting pipe inverts for this pr to be above the highest point of the D-box and all of the ES lines. A detail for a typical low vent and vent manifolc DEP approved design manual. The vent and vent manifold, as installed, is in full compliance with the approved dE vent manifold installed through offset adapters, 4"vent line installed based on <1,000 linear footage of Presby Pip Can you please confirm these statements are accurate and based on the photos and discussions we had that the installed for this project is not a remote vent. The installed vent/vent manifold is a typical low vent/vent manifold tr https://mail.google.com/mail/u/0/?ui=2&view=btop&ver-1 m2vssdml sn02&msg=%23msg-f:1739718973282461615&attid=0.1 1/1 9/20/22,4:28 PM 20220809_123110.jpg i �.e s c Y F r v Y: +a hftps://mail.google.com/mail/u/O/?tab=rml#search/851+johnson/FMfcgzGpHHPncgpgktKglHrcPFwBbKdL?compose=GTvVIcRwPVIMRnMSWkHvrsbp... 1/1 9/20/22,4:28 PM 20220809_123116.jpg _ f 5 ; https://maiI.google.com/mail/u/0/?tab=rm1#search/851+johnson/FMfcgzGpHHPncgpgktKgIHrcPFwBbKdL?compose=GTvVIcRwPVIMRnMSWkHvrsbp... 1/1 Morin-Cameron PROJECTADDRESS Est l�1tJdN�, /�• N�. GRUP, INC.i SHEET? NO. / OF CIVIL ENGINEERS I ENVIRONMENTAL CONSULTANTS CALCULATED BY DATE LAND SURVEYORS 1 LAND USE PLANNERS 66 Elm Street, Danvers, MA 01923 CHECKED BY DATE / P:978-777-8586 • F:978-774-3488 JOB NO. 40 CLIENT_- C! www.morincameron.com C tv t E7 L U � N ( •o �V %A 2 41 7 . LrWei U N + IN o r r lIx t v t