Loading...
HomeMy WebLinkAboutSeptic - Correspondence - 463 WINTER STREET 10/26/2022 ITHOMAS MANNETTA � INC0RP0RATED October 21, 2022 Stephen Casey Jr. Health Inspector 120 Main Street North Andover, MA RE: 463 Winter Street Map 104A, Parcel 69 Septic System Asbuilt Please find attached 3 copies of the revised Septic System Asbuilt for the above referenced property. Sincerely, omas :le r. Project Engineer 28 Forest Ridge Drive Rowley,MA 01969 Phone 978.887.0965 email:tom@thomasmannetta.com www.thomasmannetta.com Land Use Planners ■ Civil Engineers • Septic System Designers i 9/1122,7:56 AM Town of North Andover Mail-Fw:CGS 083122 1 NORTH ANDOVER Massachusetts Stephen Casey<scasey@northandoverma.gov> Fw: CGS 083122 1 message chad jablonski <cjablonski 1 7@yahoo.com> Thu, Sep 1, 2022 at 7:29 AM To: Stephen Casey<scasey@northandoverma.gov> Stephen, here is the sieve analysis from Torromeo for 463 winter. Sent from Yahoo Mail for Phone Begin forwarded message: On Wednesday, August 31, 2022, 1:57 PM, cgeisler@torromeo.com wrote: Methuerr TORROME O 3�Fetry30 Road INDUSTRIES INC, Methuen,MA01844 & K I l G S T O N R E D T NI I X Office 978-686-5634 Fox 978.685.6721 Cassidy Geisler ConcretoDispatch: OPERATIONS MANACta 1-800-235-TMIX(8649) W MV.lorromeo.cam CONTACT:978•609•452S in COARSE GRIT SAND 083122.pdf 16K https://mail.google.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=all&permthid=thread-f%3Al 742766621335197752&simpl=msg-f%3A17427666213... 1/1 KINGSTON READY-MIX CONCRETE 7/6/2021 KINGSTON MATERIALS A Division of Torromeo Industries, Inc., P.O. Box 2308, Methuen, MA 01844 978-686-5634 Kingston Plant at 18 Dorre Road, Kingston, NH Methuen Plant at 33 Old Ferry Road, Methuen, MA INDIVIDUAL CUMULATIVE PERCENT PERCENT TOTAL % PROJECT SIEVE SIZE WEIGHT RETAINED RETAINED PASSING ASTM C33 SPEC. 3/8" 0 0 0 100 100 TO 100 #4 1.5 0 0 100 95 TO 100 #8 230.1 20 20 80 80 TO 100 #16 353.9 30 50 50 50 TO 85 #30 221.2 19 68 32 25 TO 60 #50 176.4 15 83 17 5 TO 30 #100 124.7 11 94 6 0 TO 10 #200 50 4 98 2 0 TO 0 PAN 20.3 21 100 TOTALS 1 1178.1 100 0 F.M.: 3.21 1 2.1 TO 3.1 SIEVE ANALYSIS OF C/G/S t TOTAL%PASSING -i-MIN.DEVIATION MAX.DEVIATION 120 z 100 � 80 a 60 Q 40 20 . 0 1 2 3 4 5 6 7 8 SIEVE SIZES ggp PRESBY ENVIRONMENTAL, INC. INNOVATIVE SEPTIC TECHNOLOGIES Enviro-SepticO Training Certificate This certifies that Chad lab/onski has attended the Presby Environmental, Inc. training for: Enviro-Septic®R Leaching Systems Held in: Manchester, NH Other state or municipal licenses may be r red. March 7 2006 Date of Training David W. Presby, President Presby Environmental, Inc. I Certificate No: 1375MAES I JJTHOMAS MANNETTA I N C O R P O RATE D April 21,2022 North Andover Health Department Town Hall 120 Main Street North Andover, MA 01845 Re: 463 Winter Street Plan Review Response Numbering system in this letter conforms to the numbers used in the email dated 5/3/2022 for the project referenced above. 7. The line type used ford distinguishing the building sewer has been changed as well as a note added to sheet 1. 17. The note has been removed from the detail on sheet 1 indicating"no effluent filter needed". 19. An additional sheet has been added to clarify the best feasible replacement area. Two additional items were identified as were address,a note was added on sheet two indicating the annual maintenance of the effluent filter and the top and bottom elevations were added to the impervious barrier in the profile located on sheet 2. Sincerely, Thomas C.Mannetta Jr. ` 131atiz1,6 oo�\ pr N401e,MEND 28 Forest Ridge Drive Rowley,MA 01969 Phone 978.887.0965 email:tom@thomasmannetta.com www.thomasmannetta.com Land Use Planners • Civil Engineers ■ Septic System Designers