HomeMy WebLinkAboutSeptic - Correspondence - 463 WINTER STREET 10/26/2022 ITHOMAS MANNETTA
� INC0RP0RATED
October 21, 2022
Stephen Casey Jr.
Health Inspector
120 Main Street
North Andover, MA
RE: 463 Winter Street
Map 104A, Parcel 69
Septic System Asbuilt
Please find attached 3 copies of the revised Septic System Asbuilt for the above referenced property.
Sincerely,
omas :le r.
Project Engineer
28 Forest Ridge Drive Rowley,MA 01969
Phone 978.887.0965
email:tom@thomasmannetta.com
www.thomasmannetta.com
Land Use Planners ■ Civil Engineers • Septic System Designers
i 9/1122,7:56 AM Town of North Andover Mail-Fw:CGS 083122
1
NORTH ANDOVER
Massachusetts Stephen Casey<scasey@northandoverma.gov>
Fw: CGS 083122
1 message
chad jablonski <cjablonski 1 7@yahoo.com> Thu, Sep 1, 2022 at 7:29 AM
To: Stephen Casey<scasey@northandoverma.gov>
Stephen, here is the sieve analysis from Torromeo for 463 winter.
Sent from Yahoo Mail for Phone
Begin forwarded message:
On Wednesday, August 31, 2022, 1:57 PM, cgeisler@torromeo.com wrote:
Methuerr
TORROME O 3�Fetry30 Road
INDUSTRIES INC, Methuen,MA01844
& K I l G S T O N R E D T NI I X Office 978-686-5634
Fox 978.685.6721
Cassidy Geisler ConcretoDispatch:
OPERATIONS MANACta 1-800-235-TMIX(8649)
W MV.lorromeo.cam
CONTACT:978•609•452S
in COARSE GRIT SAND 083122.pdf
16K
https://mail.google.com/mail/u/0/?ik=fb8Oa9478f&view=pt&search=all&permthid=thread-f%3Al 742766621335197752&simpl=msg-f%3A17427666213... 1/1
KINGSTON READY-MIX CONCRETE 7/6/2021
KINGSTON MATERIALS
A Division of Torromeo Industries, Inc., P.O. Box 2308, Methuen, MA 01844 978-686-5634
Kingston Plant at 18 Dorre Road, Kingston, NH Methuen Plant at 33 Old Ferry Road, Methuen, MA
INDIVIDUAL CUMULATIVE
PERCENT PERCENT TOTAL % PROJECT
SIEVE SIZE WEIGHT RETAINED RETAINED PASSING ASTM C33 SPEC.
3/8" 0 0 0 100 100 TO 100
#4 1.5 0 0 100 95 TO 100
#8 230.1 20 20 80 80 TO 100
#16 353.9 30 50 50 50 TO 85
#30 221.2 19 68 32 25 TO 60
#50 176.4 15 83 17 5 TO 30
#100 124.7 11 94 6 0 TO 10
#200 50 4 98 2 0 TO 0
PAN 20.3 21 100
TOTALS 1 1178.1 100
0 F.M.: 3.21 1 2.1 TO 3.1
SIEVE ANALYSIS OF C/G/S t TOTAL%PASSING
-i-MIN.DEVIATION
MAX.DEVIATION
120
z 100
� 80
a
60
Q 40
20 .
0
1 2 3 4 5 6 7 8
SIEVE SIZES
ggp PRESBY ENVIRONMENTAL, INC.
INNOVATIVE SEPTIC TECHNOLOGIES
Enviro-SepticO Training Certificate
This certifies that
Chad lab/onski
has attended the Presby Environmental, Inc. training for:
Enviro-Septic®R Leaching Systems
Held in: Manchester, NH
Other state or municipal licenses may be r red.
March 7 2006
Date of Training David W. Presby, President
Presby Environmental, Inc.
I
Certificate No: 1375MAES
I
JJTHOMAS MANNETTA
I N C O R P O RATE D
April 21,2022
North Andover Health Department
Town Hall
120 Main Street
North Andover, MA 01845
Re: 463 Winter Street
Plan Review Response
Numbering system in this letter conforms to the numbers used in the email dated 5/3/2022 for the project
referenced above.
7. The line type used ford distinguishing the building sewer has been changed as well as a note added to sheet 1.
17. The note has been removed from the detail on sheet 1 indicating"no effluent filter needed".
19. An additional sheet has been added to clarify the best feasible replacement area.
Two additional items were identified as were address,a note was added on sheet two indicating the annual
maintenance of the effluent filter and the top and bottom elevations were added to the impervious barrier in the
profile located on sheet 2.
Sincerely,
Thomas C.Mannetta Jr. `
131atiz1,6 oo�\
pr N401e,MEND
28 Forest Ridge Drive Rowley,MA 01969
Phone 978.887.0965
email:tom@thomasmannetta.com
www.thomasmannetta.com
Land Use Planners • Civil Engineers ■ Septic System Designers