HomeMy WebLinkAbout1988-01-12 Department Review SPR NORTH ANDOVER 1 W1 F'F i4a�;}
k
POLICE DEPARTMENT
Officer's Report C
Subject —Site Plan Review-Digital Consulting.
.�•_
Date October 6 , 198y Time
Names & Addresses of persons involved:
This building at the intersection of Hillside Road and Rte . 125 7-Pass ,
T!5 an area a e Police Department should have._ serious concern about .
There is a ] arge development on the opposit side of the y- ass and bo=—
projects will Aahhve an impact on the number of vehicles in this area.
1 feel that this Dept . should ask the Planning Board to work very closley
with the State D.P.W. on this area . Special attention should be paid to
this .location in hopes that the traffic generated by this building and
any others which are in the planning stage will not cause a dangerous
condition at the intersection of Hillside and By-Vass .
I would like to consider making all traffic out of this building turn
onto the By-Vass . We cannot afford to have any more impact on the traffic
on Rte . 114 Turnpike St . Traffic could possably go .left through the
parking lots. at Chestnut Greens and onto Rte . 114 .
The Police Dept . should request the right to bring to the attention of
the drveloper any serious problems that might arrise during the construction
of this project .
l
Officer's Signature
i
oo
NORTH ANDOVER FIRE DEPARTMENT
CENTRAL. FIRE HEADOUARTERS
X° Naren n S
0Y1LJ.-1AM!V. 00[_AN `del. ( 1"7) 686-.3812
Chief of OoptWrr eo!
To: Scott Stocking, Town Planner � S
From: Fire Chief Dolan i
Re. Digital Consulting-Hillside Road
Date: October 5, 1987
I have the following comments regarding this project:
1 . The proposed overhead to the rear should provide adequate
clearance for Fire Department vehicles . A minimum clear-
ance of twelve feet is needed.
2. The building will be fully sprinklered in accordance
with MGL Chap. 148 sec. 26G. Plans for the system must be
submitted to the Fire Chief for approval prior to installation.
3. An automatic fire detection system to include, but not limited
to, smoke and heat detectors, double action pull stations,
horn lights outside annunciator panel, control panel and master
fire alarm box will be required. Plans for this system must
be submitted to the Fire Chief for approval prior to install-
ation.
4 . All systems shall be tested and approved prior to occupancy.
I intend to be present at the October 19 meeting of your board.
William V. Dolan, Fire Chief
( 1-FICES OF: �? i� Town Of 12(?N-1 ►irl S11'C(A
APPEALS N4R't'H ANll(�VEit No rtlti Andover,BUILDINGfir'° r,e:•'ao Mass"lchuseltso1845 CONSERVATION eBCHU9A4 DIVISION OF (617)68 5.4775
HEALTH
PLANNING PLANNING & COMNIUNI'I'Y UEVELOPML�N'I'
KAREN I i.i'. NELSON, Dfl tl;C CUR
STAFF REVIEW
SITE PLAN REVIEW PLANNING BOARD MEETING
October 19 , 1987
PROJECT: Digital Consulting Office Building
LOCATION: Hillside Road & Andover Bypass
APPLICANT: Dr . George & Sandra SchussellDESIGNERS : Merrimack Engineering
Services
EXISTING CONDITIONS: Old foundation, wooded lot Joseph D. LaGrasse & Assoc .
Architects
SUMMARY:
CURRENT ZONING: Business-4 (B-4) District
REQUIRED PROVIDED
MINIMUM LOT AREA 80 , 000 sq. ft. 80 , 208 sq. ft.
FRONT YARD (Min) 5 0 ' 5 2 '
SIDE YARD (Min) 50 ' 80 ' +
REAR YARD (Min) 50 , 1301 +
ROADWAY FRONTAGE (Min) 200 ' 290 '
PARKING 60 63
SQ.FT. OF STRUCTURE 25 , 035 sq. ft. gross floor area
STORIES: 3 Floors 19 , 675 occupied space
BUILDING HEIGHT: 45 ' (max . allowed 60 ' )
% OF LOT COVERAGE/STRUCTURE 25% 7%
FLOOR-AREA-RATIO 1 : 50 : 1 . 31 : 1
This Site Plan calls for improvements on a legal lot of record.
l
TOWN DEPARTMENT COMMENTS:
FIRE: Minimum clearance for the rear of the structure is 121 .
Fire safety concerns for the structure- see letter from
Fire Chief, dated October 5 , 1987 .
POLICE: Serious traffic safety issues in this area. Suggest
close coordination with State DPW. Impact on the
intersection of Hillside Road and Andover Bypass
should be studied closely, along with access problems
with traffic going through the Chestnut Green Development
and onto Route 114 .
HEALTH:
PUBLIC WORKS:
OTHER TOWN BOARDS/COMMISSIONS
CONSERVATION COMMISSION: Order of Condition issued July 24 , 1987
Wetland delineation shown on the plan is correct.
- Retaining walls are OK with site review.
-- All embankments in the -buffer zone shall be 2 : 1
All catch basins shall have oil and gasoline traps .
STATE DEPARTMENTS
DPW: Letter sent to Joseph DiAngelo on October 8 , 1987 , requesting
input regarding the Hillside Road and Andover Bypass
intersection.
DISCUSSION:
Staff has met with the project architect, Mr. LaGrasse and
the following items of concern were expressed.
1 . Location of the building was determined by the requirements
of the Conservation Commission and the Fire Department.
2 . Adequately screening the parking areas from adjacent
roadways and residents .
Upon staff visiting the site and a more detailed review of the
plans on October 8 , 1987 , staff has the following concerns which need
to be addressed prior to approval:
Traffic :
1 . Access to this site will be provided from Hillside Road
from Route 125 and the driveways found in the Chestnut
Green Office Complex off Route 114 . Possibly 60 employees
(using 300 square feet per employee standard) along with
visitors to the building each day will add to access
problems in this area. Existing driveway problem at the
Chestnut Green site needs to be addressed.
2 . The Town may require the applicant to supply a traffic
impact study to measure the ability of the existing
road network to handle more traffic.
3 . Letter sent to State DPW requesting comments on the
impacts this project will have to the existing
road network.
Drainage :
1 . Explore the possibility of placing retention ponds to
to hold storm water on-site prior to outfall into the
resource areas.
2 . Are additional catch basins needed along the parking
areas facing Hillside Road?
3 . All site drainage must go to the rear of the property
away from Hillside Road, into the resource areas .
Parking:
1 . Attempt to remove the two parking spaces along Hillside
Road to provide some additional open space on-site .
2 . Attempt to move the parking further off Hillside Road to
allow the existing trees to be maintained along the
roadway.
3 . Attempt to move the parking spaces adjacent to the building
closer to the structure to allow better access to the
rear of the property.
Sign Location:
1 . Please indicate the site of project sign. . The sign
must meet the Town' s Bylaw Requirements .
Landscaping:
1 . It should be the goal of the developer to save as much
of the existing tree cover found on the site as possible.
Additional landscape material may be added to help
supplement the existing vegetation found on the site .
2 . In accordance with Section 8 . 4 , the applicant shall meet
the following landscape standards :
A. 6 ' wide strip of land densely planted with trees
and scrubs expected to form a year round impervious
screen at least 5 ' high.
B. On three side of the perimeter of the parking
area one tree 31 'Diameter Brest Height (DBH)
at least 4 ' high shall be planted at a rate
of one for every 30 ' linear feet. (14 trees are
required)
C. The trees shown on the planting island in the
parking lot is sufficient.
D. Planting and location of island adjacent to the
structure needs redesign due to the narrow
drive and the location of the parking spaces .
Lighting:
The location and type of exterior lighting for this site needs
to be shown on the plan.
Walls:
Please supply the specifications for the retaining walls to be
built on the site.
Dumpster:
Specify the location of tht3- dumpster to be utilized for
garbarge collection.
i
TOWN OF NORTH ANDOVER, MASSACHUS TTS
DIVISION OF PUBLIC WORKS
I
384 OSGOOD STREET. 01645
I
PAuL 5• NiMAN Ty' �Eioiv 81.7=9,Cog
� .
DIRECTOR ttORTH
o
I
October 20, 1987
Paul. Hedstrom, Chairman
Planning Board
120 Main Street
North Andover, Mass 01845
re: Digital Consulting Site
Dear Paul:
The Division of Public Works has reviewed the plans of the proposed
Digital Consulting site and have the following recommendations to make.
1. A new 12" C.L.D.T. water main was installed on hillside Rd, and
recently placed in service. The proposed water service should be
connected to a new 12" pipe.
2. A new 8" gravity has been constructed with a terminus on Hillside Rd
at the easterly side line of the Andover By--Pass. The sewer will
be connected to the proposed Alcott Village Pumping Station which
is designed to handle the flow from all of Hillside Rd. The sewer
service connection from the proposed building should be extended
westerly on Hillside Rd. to the existing new sewer.
Very truly yours, f
f
J, William Hmurciak
Director of Engineering & Admistration
JWH:jm
nSinnrKA
OFFICES OF: s Town of 120 Maii I Strect
APPEALS North An(-love r,
NORTH ANDOVER
_1LASC
BI 7ILDING -1(',l A tS 0 184
CONSERVATION esgDIVISION OF, (617)G8S-477S
HLuAL,Ti I
PLANNINGY PLANNING & COMMUNITY DEVELOPMENT
KARFN I I.P. NFI-SON, L)IRE.-C-FOR
V!
DATE: NOVEMBER 23, 1987
TO: PLANNING BOARD
FROM: DANIEL MaCONAGHY, ASS'T BUILDING INSPECTOR
RE: DIGITAL BUILDING, ANDOVER BY-PASS
IN CALCULATING THE REQUIRED PARKING FOR THIS BUILDING., PLEASE NOTE AS
FOLLOWS: IT WILL REQUIRE 66 SPACES PLUS 3 HANDICAPPED SPACES. THE
8 PARKING SPACES IN THE GARAGE WOULD NOT BE REALISTIC OR PRACTICAL)
THEREFORE, THIS OFFICE WILL ONLY ACKNOWLEDGE 2 PARKING SPACES IN THE
GARAGE WHICH WILL LEAVE ROOM FOR LOADING AND UNLOADING OF DELIVERIES.
A b
ro 61