Loading...
HomeMy WebLinkAbout- As-Built Plan / Installation Certificate Form - 24 FARNUM STREET 12/11/2022 SUMMARY OF INVERTS BUILDING TIES SEWER 0 FDTN. 96.95. BLDG. CORNER A B C D Q THIS PLAN & CERTIFICATION IS NOT SEPTIC TANK IN 96.71 SEPTIC TANK. IN 15.0 26.4 - - A WARRANTY OF THE SUBSURFACE DISPOSAL . SEPTIC TANK OUT 96.46 SEPTIC TANK OUT 17.8 20..5 - -- SYSTEM. IT IS A RECORD OF THE LOCATION PUMP TANK IN 96.38 PUMP TANK OUT 26.3 14.5 -- - AND ELEVATION OF THE EXISTING SYSTEM DIST. BOX IN 101.5.6 DIST. BOX 52.0 32,8 -- I — COMPONENTS. DIST. BOX OUT 101.43 "I HEREBY CERTIFY THE LOCATIONS, ELEVATIONS, TIES, COVER MATERIAL; LEACH LINE BEG 101.36 ,EXPOSED COMPONENT COVERS ETC., SHOWN ON THIS AS—BUILT SUBSTANTIALLY LEACH LINE END 101.13 AGREE WITH THE APPROVED PLAN AND HAVE DETERMINED THAT THE BREAK OUT ELEVATIONS, IF APPLICABLE, HAVE BEEN MET.- APPROVED DESIGNS PLANS. � SIG# ATURE OF DESIGNEW DATE LOT A (3 ACRES) Ln co 0 n co °ec .-1500 GAL. I SEPTIC TANK PORCH Q�4� 1 F'4�y 42' l!SL 4 BORA1. EDGE OF #g M 10 fl 1000 GAL. PorFN1AL PUMP TANK IL I 1 01ST. 80X 13p' 31' I Ilf 4 43. I LEACH FIELD c600 S.F.) I � f 3 I VENT INSP. PORT r FARNUM STREET cv AS BUILT PLAN OF SUBSURFACE DISPOSAL SYSTEM LOCATED IN 0 0 NORTH ANDOVER, MASS./24 FARNUM STREET AS PREPARED FOR °F WARREN SIDERI 0. ��VLADIMIR DATE: 12-11-22 TM: 107A U2 NEMCHENOK SCALE: 1"=40' TL: 24 0 20 40 N�� S0 A� MERRIMACK ENGINEERING SERVICES 66 PART{ STREET ANDOVER, MASSACHUSETTS 01810.