HomeMy WebLinkAboutSeptic Approval Letter - Correspondence - 73 CARLTON LANE 3/23/2023 North Andover Health Department
Community and Economic development Division
March 23, 202
Mr. cr Mrs. Rich l Iorfan
7:3 Carlton Lane
North Andover, MA 0 18 a
Re: Septic Connection Plan for 73 Carlton Lane (Map 106C, Lot 20)
To Mr. & Mrs. tforpan:
The proposed septic connection design plan for the above site dated Novernber 2022 with a
signature date of 3/2`2; in the designer-certification statement has been approved I'i)r- issuance:of`
a I)isposal System Construction l'errnit (1)SC"I:). Ctrace, issued, a l:)SC P will authorize the
construction of'the septic tam and pun7p systein per the plan t-cferenced above and ors allowed
under-Title 5 of"the Massachusetts I.'nvironnrental C:`ode (310 CM 15.000). You will need
involvement from the designer ot`the onsite wastewater system throughout the installation
process scar you should be sure to coordinate with theist.
The design has been approved for use; in the c onstrr.rction of'a new connection to an existing on-
site wastewater system utilizing a new septic tank and ar new pump c;harnber along with the
proposed effluent filter in the septic tank:.
']'his design plan approval is valid for 2 yearn; f"rant the above dame. Luring this time, a licensed
septic system installer should obtain a permit and complete this; work, arrcl ar Certificate of.
C'onipliance be endorsed by the installer, designer and the "I:"own ol'North Andover, lf`t.liese
activities are not completed within this time period then it is possible a new design plan will creed.
to be completed and submitted for review.
Phis approval is subject to the 1i71lowing conditions. Please be sure to review these with the
designer and installer.
Page I of,3
North Anclover I Tcaalth Lepartanent., Town l fall, 120 Main Street.,
North Andover, MA 01845 Rhone: 978.688.9540 1,"ax- 978,688, 9542
Prior to the issuance of"a Disposal System Construction Permit:
a. Three additional paper copies of the design plan are to be provided to the office
1). The applicant must submit as f'OUndation as-guilt at the same scale as the approved
plan with the proposed onsite wastewater system components also depicted along,
with ties to the fioundation
c. Prior to the issuance of the Disposal System ConstrUCtiOn Permit, the applicant
111USt submit the floor plans of the proposed structure
Throughout the project:
If"site conditions are found it) the field to be different from those indicated on the
design plan, installation ofthe onsitc wastewater system sliall stop and (lie
designer and this office notified within 24 hours
b. The brand and model ofet'lluent filter specified on tlle design plan is to be
utilized. The installer is to demonstrate these have been made part of the onsite
wastewater system
c. Inspections are to be perfortned by the designer of the onsite wastewater system
as needed to properly oversee and document construction
d. Inspections are to be completed by, the Town of"North Andover at a minimurn as
follows:
i. Tank bottorn
ii. Final installation of'con)ponents, confirmation of proper component
selection, examination ofconstruction methodology. and system operation
iii. Final grade
c. 'No components are to be cm,ered until as final component inspection has been
completed
E No excavation for or work associated with construction of the soil absorption
system is to occur from November 30 to April I
After construction:
g. Within 30 days ofcompletion ofconstrUCtion the hist.,iller and designer are to
confirin if the installation work was completed in cornpliance with the design playa
referenced in the DSCP and with Title 5, and if`so shall certify this on as
Certificate of Compliance farm.
h. If changes have been madc to (lie approved plans then preptration of an as-built
plan is required to be completed by the designer. lino changes have been made
to the approved plans then the approved plan shall be modified by the designer to
show the distances from as known structure to the systern conil',ments.
i. No sewage shall be dischargcd to the onsite wastewater system until a Certificate
Of COMpliance has been issued by this office
f. No application for a Certificate of 0ccupancy may be requested from the Building
Inspector rintil a Certificate ofCompliance has 1wen issued by this office
In addition, You Should be aware of the long-term operation guidelines of an onsite wastewater.
system (these are not part oftlic DSCP but are jnenti(:)ned below,as information for the property
owner):
Page 2 of 3
North Andover Health Departi-nent, 'Town I JaIL 120 Main Street,
North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688. 9542
I. An onsite wastewater sy stern can function as an iritegra] part ofthe of
the property if it, is properly operaled and rnaintairicd. This is the responsibility oftlic
owner ofthe property and is generally not specified by regulation. YOU are
encouraged to contact a wastewater system puniper/service provider to partner with
YOU to i I'll I)Iel 11CIlt Steps Ileeded to assure the longevity ofthe onsite wastewater
system being installed at this location
I The design plan specifies the use ofan effluent filter inside the lank. This component
is required to be examined at le�.tst annually and cleaned as needed
The issuance of a DS(111 does not, construe and/or imply, compliance with any permits, approvals
or licenses which might be needed from other agencies such as the Conservation ('01111nission,
Zoning Board, Planning Board, Building 111SI)eCtOr, PlUrribing Inspector and/or I'lectrical
Inspector.
Please feel free to contact the office with art.),, questions YOU May have, We look forw,,ird to
working with you to obtain a wastewater treatment and dispersal systern which will be ill
compliance with all regulations and assure protection ot'public licalth And the environment of'
North Andover.
Sincerely,
Brian J. LaGrasse, (TIFF
Director offlublic, I leal th
F'riel. Installers list
cc: 13uilding Inspector
Brendan Pyburn,
File
Page 3 of 3
North Andover Health Departnient, Town Hall. 120 Main Street.
North Andover, MA 0 1845 phone,: 978.688.9540 Fax: 978.688. 9542