Loading...
HomeMy WebLinkAbout1987-02-25 Department Review SPR WITHDRAWN T;0RTy rptS�rsn }6�HOp` BOARD OF HEALTH 0" 120 MAIN STREET ATIOUS �y NORTH ANDOVER, MASS. 01845 TEL. 682-6400 Oct 30,1986 No.Andover Planning Board Re : Lot 2 Holt Rd No.Andover, Mass Gentlemen: I have already approved a septic system design that was based on the building dimen- sions and u ses shown on the current plan of 10/9/86 Yours truly, 4 Michael Graf Inspector ,j a rr f7 CENTRAL FIRE HEADQUARTERS NORTH ANDOVER FIRE DEPARTMENT 124 Main Street North Andover, Mass, 01845 (3r)ieJ of D partmont To: Karen Nelson, Town Planner From: Fire Chief Dolan Re: Lot 2 Holt Road - site plan review Date: October 30, 1986 T received a plan dated October 9, 1986 for Lot 2 Holt Road. The plan submitted does not meet the plan requirements of the site plan review 8 . 3 of the Zoning By-Law and should not-:.be considered. As always, the Fire Department will submit comments for a proper plan. ������cJ... r William V. Dolan R 1 1 TOWN OF NORTH ANDOVER 120 Main Street North Andover, MA. 01845 685-4775 e µOrt7H � a November 6 , 198,6 Joseph T. Cristaldi 161 Massachusetts Avenue North Andover, MA 01845 Re: Holt Road -- Site Plan Review Dear Mr. Cristaldi : I have reviewed the revised plans for Holt Road. There are a number of deficiencies which need to be corrected prior to the Public Hearing on November 17 , 1986 . The following items are needed: 1 . Locus Map, 2 . stamps on plans by an architect, an engineer/ surveyor and .by a landscape architect, 3 . Zoning on plan, 4 . Landscaping plan, 5 . Drainage calculations . Please contact the Planning Office at your earliest convenience with this information. These plans are still subject to review by the various Town Departments and may require additional. changes . If you have any questions please contact the Planning Office . Sincerely yours , PLANNING OFFICE Tricia Wrenn Assistant Town Planner TW:ns � J CONSERVATION COMPASSM jV November 14, 1986 T0: Planning Board Fy— FROM: T. Peter, Conservation Administrat r " DATE: November 14, 1986 ` RE: Lot 2 - HOLT ROAD �. This site islocated within 100 feet of a wetland resource area. Currently this .lot is open and void of proper erosion controls. The applicant should place erosion controls on site immediately and arrange for an on site visit with the NACC. c: Angelo Cristaldi TAP/mlb PLAk N.1 VOWkN OF iqORYPI AU-U-10VER, P.11ASSACkIUSEY'r CONSERVAI'04 CON14AIWON rrAAJ-'K0NE 693-7M Y December 2, 1986 TO: Planning Board FROM: Tracy A. Peter, Conservation Administrator RE: Lot 2 - Holt Road During a site visit which I made with Mr. Cristaldi on November 26, 1986, 1 noted that P6 previous letter had referred to the wrong Lot. The actual site does not appear to contain any wetlands. However, I would like to mention that the adjacent Lot has been uncovered and siltation could easily run into the storm drainage system. I will also notify the Highway Surveyor about this condition. c: William Cyr TAP/mlb DIVISION OF PUBLIC WORKS 384 OSGOOD STREET 4q TOWN OF NORTH ANDOVER, MASSACHUSETTS 01845 9SSA��6sk� 685-0950 William A. Cyr Superintendent of Highways, Utilities, & Operations Leo Lafond, William Hmurciak, Supervisor of Forestry & Grounds Director of Engineering & Administration 683-9381 687---7964 December 29, 1986 Planning Board rich Nitzsche, chairman 120 Main Street North Andover, Mass. Re: Lot 2 Holt Road Angelo Czistaldi Dear Erich; T have reviewed plan and make the fallowing comments. 1. Three driveway entries are not necessary. Two entries are more than adequate and minimizes the problems associated with any driveway entry on a grade of 60 . Lot entry should be reduced to two entries. Driveway entry permits will be required and driveway entr2es-:will! meet conditions set in driveway entry specifications. 2. Drainage as shaven on plan is not adequate to handle site run off. Existing street: drainage is not designed to handle undeveloped lot drainage from lots on the southerly side of Holt Road. Either drainage retension has to be built into site or an additional drainage system must be constructed from site to the brook several hundred feet to the east of lot on Holt Road. No site drainage will be allowed to tie into existing street drain system. We are experiencing problems with drainage from these lots now and properly controlled drainage from future lot development in this area is a must. Sincerely, William A. Cyr Superintendent WAC/cc a , �0 � 1 a uw jib.