HomeMy WebLinkAboutConstruction Notes - Consultant Review - 50 JAY ROAD 10/3/2023 North Andover Health Department
(ommunity and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 50 Jay Road MAP: 98.A LOT: 59
INSTALLER: James Boraczek - 978-479-5236
DESIGNER: Benjamin Osgood — 978-208-1762
PLAN DATE: 12/15/2022
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
TANK INSPECTION:
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
Contractor reports any changes to design plan
Existing septic tank properly abandoned, if
present
/Internal plumbing all to one building sewer
0/ Topography not appreciably altered
Comments:
SEPTIC TANK
Building sewer in continuous grade, on
compacted firm base
Cleanouts per plan
Bottom of tank hole has 6" stone base
Tank size and loading per plan
❑ Monolithic tank construction / 2-piece
(circle one)
�If monolithic, water tightness of tank has been
achieved by visual testing
❑ If 2-piece, water tightness of tank has been
achieved by water/ vacuum test (circle one)
Inlet tee installed, centered under access port
Outlet tee installed, centered under access port
rr as baffle / effluent filter installed (circle one)
l�I 4 l I If effluent filter, riser to finished grade over filter
Riser with cover to within 6" of finish grade
installed over one access port
Manhole and riser minimum Ild inch diameter
Pipe penetrations appear watertight using
rubber boots / hydraulic cement (circle one)
Comments:
PUMP CHAMBER
(Delete if not present) Bottom of tank hole has 6" stone base
Weep hole plugged
1000 gallon Pump Chamber installed
oAs�1� G [� H-10loading
Monolithic tank construction
Inlet tee installed, centered under access port
Pump(s) installed on stable base
Alarm float working
Pump On/Off floats working
Drain hole in pressure line
cover at final grade installed over pump
access port
Water tightness of tank has been achieved by
Visual or watertightness testing
Neoprene boots around inlet & outlet
Comments:
CONTROL PANEL
(Delete if not present) / �isual
larm & Pump are on separate circuits
[!]' & audible alarm works as intended
Location of control panel:
Comments:
DISTRIBUTION-BOX
Installed on stable stone base
H-20 D-Box
Inlet tee (if pumped or >0.08'/foot)
Hydraulic cement around inlet & outlets
Even distribution observed
Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTE General)
Bottom of SAS excavated down to specified
soil layer, as provided on plan
ize of SAS excavated as per plan
Sand installed, if specified on plan
Sand displays few fines when handled
0 Mil HDPE barrier installed, if specified on
design plan
Laterals installed and ends capped or
connected to header (and vented if impervious
material above)
�--Retaining wall material, location and height if
specified on plan
Comments:
SOIL AB P IONS TEM (Gravel-less Chambers)
❑ Brand and Model of Chamber:
�(Ql� ❑ Number of chambers per row and number of
rows per design plan: ,
❑ Elevations of laterals and chambers installed as on
approved plan
Comments:
SOIL ABSORPTION SYSTEM (Other)
FINAL GRADE
[� Final cover as per plan
[(� Loamed
Seeded
Cover per plan
Comments:
DOCUMENTS NEEDED
❑ Certification of Installation Form submitted
by designer and signed and dated by
designer and installer
❑ As-Built Plan by designer
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
Distribution Box OUT
Lateral 1 BEGINNING
Lateral 1 END
Lateral 2 BEGINNING
Lateral 2 END
Lateral 3 BEGINNING
Lateral 3 END
Lateral 4 BEGINNING
Lateral 4 END
Lateral 5 BEGINNING
Lateral 5 END
Lateral 6 BEGINNING
Lateral 6 END
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
❑ Property line 10 10 --
❑ Cellar wall 10 20 --
❑ Inground pool 10 20 --
❑ Slab foundation 10 10 --
❑ Deck, on footings, etc 5 10 --
❑ Waterline 10 10 I 0,
❑ Private drinking well 75 1002 50
❑ Irrigation well 75 100
❑ Surface Water 25 50
❑ Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
❑ Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
❑ Trib. to surface water supply 325 325
❑ Public well 400 400
❑ Interim Wellhead Prot.Area
❑ Reservoirs 400 400
❑ Drains (wat. supply/trib.) 50 100
❑ Drains(intercept g.w.) 25 50
❑ Drains (Other)Foundation 10(5) 20(10)
❑ Drywells 20 25
1 Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws