HomeMy WebLinkAboutRepair Comp - Pipe - Consultant Review - 25 CEDAR LANE 4/8/2024 North Andover Health Department
Cornnrunity and Economic Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 26 Cedar Lane MAP: 'I06.A LOT: 0147
INSTALLER: Todd Bateson
INSPECTIONS � '2
7825 — Install new pipe from foundation to tank
SEPTIC TANK. D. Building sewer in continuous grade, on
compacted firm base
Cleanouts per plan
Bottom of tank hole has 6" stone base
Tank size and loading per plan
Monolithic tank construction / 2-piece
(circle one)
If monolithic, water tightness of tank has been
achieved by visual testing
[� If 2-piece, water tightness of tank has been
achieved by water / vacuum test (circle one)
inlet tee installed, centered Linder access port
Outlet tee installed, centered under access port
comas baffle / effluent filter installed (circle one)
El If effluent filter, riser to finished grade over filter
Riser with cover to within 6" of finish grade
installed over one access port
El Manhole and riser minimum inch diameter
Pipe penetrations appear watertight using
rubber boots / hydraulic cement (circle one)
Comments: