HomeMy WebLinkAboutConstruction Notes - Consultant Review - 125 GRAY STREET 6/25/2024 North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 125 Gray Street MAP: 107.D LOT: 0056 INSTALLER: Todd Bateson DESIGNER: Vladimir Nemchenok / Bill Dufresne – 978.475.03555 PLAN DATE: 09.15.2023 BOH APPROVAL DATE ON PLAN: 10.11.2023 INSPECTIONS TANK INSPECTION: 11.01.2023 – B. LaGrasse DATE OF BED BOTTOM INSPECTION: B. LaGrasse DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: 11/9/23 - D. Ottenheimer SITE CONDITIONS Contractor reports any changes to design plan Existing septic tank properly abandoned, if present Internal plumbing all to one building sewer Topography not appreciably altered Comments: SEPTIC TANK Building sewer in continuous grade, on compacted firm base Bottom of tank hole has 6” stone base Tank size and loading per plan Monolithic tank construction If monolithic, water tightness of tank has been achieved by visual testing Inlet tee installed, centered under access port Outlet tee installed, centered under access port Gas baffle installed If effluent filter, riser to finished grade over filter Riser with cover to within 6” of finish grade installed over one access port Manhole and riser minimum 20 inch diameter Pipe penetrations appear watertight using rubber boots Comments: DISTRIBUTION-BOX Installed on stable stone base H-20 D-Box Inlet tee (if pumped or >0.08’/foot) Hydraulic cement around inlet & outlets Even distribution observed Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) Bottom of SAS excavated down to specified soil layer, as provided on plan Size of SAS excavated as per plan Sand installed, if specified on plan Sand displays few fines when handled 40 Mil HDPE barrier installed, if specified on design plan Laterals installed and ends capped or connected to header and vented Retaining wall material, location and height if specified on plan Comments: SOIL ABSORPTION SYSTEM (Other) FINAL GRADE Final cover as per plan Loamed Seeded Cover per plan Comments: Shanene Pierce DOCUMENTS NEEDED Certification of Installation Form submitted by designer and signed and dated by designer and installer As-Built Plan by designer BM = 100.00 HR = 3.05 HI = 103.05 SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Building Sewer OUT 4.84 97.88 97.90 Septic Tank IN 5.78 96.94 96.85 Septic Tank OUT 6.01 96.71 96.60 Distribution Box IN 6.26 96.46 96.40 Distribution Box OUT 6.44 96.28 96.23 Lateral 1 BEGINNING 6.51 96.21 96.15 Lateral 1 END 6.75 95.97 95.90 Lateral 2 BEGINNING 6.51 96.21 96.15 Lateral 2 END 6.75 95.97 95.90 Lateral 3 BEGINNING 6.51 96.21 96.15 Lateral 3 END 6.75 95.97 95.90