Loading...
HomeMy WebLinkAbout1985-04-26 Department Review DEF SUB TOWN OF NORTH ANDOVER NORTH ?0 �t �611 LEO E. LAFOND o TEL. 683-93e1 SUPERINTENDENT OF * -j ,� 384 OSGOOD STREET INSECT PEST CONTROL & y f�';.?, ." �► NORTH ANDOVER, MASS. TREE WARDEN «n� (6(nf(n�v.,{r<V OAT$ r?A`,t'�y SSACHU�� INSECT PEST CONTROL AND TREE DEPARTMENT May 28, 1985 ;:fanning Board Town Office Building North Andover, Ala. Gentlemen: Re:-. Shannon bane Subdivision All requirements of the subdivision control laws pertaining to "Street Frees" shall be enforced by this department. I would therefore recommend that bond money in the amount of b1 ,800 be retained for this purpose. Very truly yours, Leo E. Lafond, Tree Warden i i 1 � tyOR7►f BOARD OF HEALTH 0 120 MAIN STREET �Rssao4us� NORTH ANDOVER, MASS. 01845 TEL. 682-6400 May 28 , 1985 Planning Board No.Andover Re : Shannon Lane Mass . Gentlemen: Testing has been completed for five lots on this subdivision and most of the results are acceptable . No septic system plans have been submitted as yet ,but the septic systems will be different from those shown on the subdivision plan. In fact, the most sutable site for the Leach area on Lot 4 is shown at only approximately 80 feet from the proposed drain easement . Very truly yours , Michael Graf, Inspector mg:mj f NORTH ANDOVER FIRE DEPARTMENT CENTRAL FIRE HEADQUAR"rERS '124 Main Street 4 t Norfti Andover, Mess, 01845 To. No. Andover Planning Board From: Fire Chief Dolan P;gfyti( Re : Shannon Lane-Definitive Plan Date: May 10, 1985 P1ANN1A G 13��A D I have reviewed the plans for this proposed subdivision and have the following comments : 1 . The hydrant at the cul-de-sac is over 500' from Farnum Street. The next two nearest hydrants are at the corner of Summer and Farnum and at #160 Farnum St . near Gilman Lane. ,/In order to provide water for fire protection needs as indicated in section VF water facilities of the subdivision control regulations, a hydrant should be in- stalled 500' from the hydrant at Summer and Farnum Streets on Farnum St . . 2 . All lot numbers shall be posted during construction. 3 . Permanent house numbers shall be posted on dwellings prior to occupancy. 4 . No open burning is to be permitted except during open burning season under fire department regulations, 5 . All builders must comply with the fire departments underground fuel storage regulations . 6. Prior to taking occupancy, the subdivision streets shall provide adequate access to each residence for fire apparatus . 441 William V. Dolan, Chief f NORTH ANDOVER r FIRE. DEPARTMENT CEN"I'"RAL FIRE HEADQtJARTERS �1V I t_�.I f11l� V. [DO[-AN 'Tel. ( 1 ) F3 m °1 C hlef of Dcfp�rfrrwol Date: May 31, 1985 To: No. Andover Planning Board JUN . . From: Chief Dolan Re: Shannon Lane PLAN ING 130A My comments in regard to the revised plans for this subdivision are as in my prior letter of May 10 , 1985. William V. Dolan, Chief James D.Nobla,Jr.Clark Jahn P.Thompson,Chalrman Raymond J.Canty, TOWN OF NORTH ANDOVER, MASS. M BOARD OF PUBLIC WORKS • WATER,SEWER,PARK,PLAYGROUND AND SCHOOL GROUNDS DEPARTMENT �►�� ' ' s M SUPERINTENDENT AND ENGINEER JOSEPH J. 80RGES1 �?ACHus TELEPHONE 687-7964 June 28, 1985 Z Ira Michael Roberts, Chairman Res Shannon TLane Planning Board 120 Main Street North Andover, MA 01.845 Tear Mike: The Board of Public Works has reviewed the Plans of the proposed Shannon Lane subdivision and have the following recommendations to make: 1° The water main on Shannon Lane shall be 8" class 52 ductile .iron cement lined water pipe installed. 10 heat left of the centerline of the road with 5 feet of cover below the finish grade from the existing water main in Farnum Street to Station 5+20. 2° An 81I x 81r tapping sleeve and gate valve (open left) shall be provided at the existing waster main in Farnum Street. 3. Eddy Break .flange hydrants to North Andover specification are to be installed at station 0+0 and 5+20 4+ All hydrant branches skull be provided, with six inch Mueller or equal., gage valves (open 1'eft) 5. All pate valves shahl comply with AWWA specifications L500 52T and will be suppl6d with a. 100 lb. sliding type gate box marked. "WATER" 6° All water mains shall, pass leakage and pressure test performed in accordance with section 13 of the AWWA standard C600 and shall be chlorinated in accordance with AWWA C601 "Standard Procedure for Disinfecting Water Mains. " Very truly yours, ,r B RD .OF PU ir1C WORKS illi.am,Hmurci.ak S gaff Engineer JW11/wh i James D.Noble,Jr.Clerk 1 John P.Thompson,Chairman Raymond J.Canty, TOWN OF NORTH ANDOVER, MASS. MORrk �r O'•j "o •1�OOC BOARD OF PUBLIC WORKS i WATER,SEWER, PARK,PLAYGROUND AND SCHOOL GROUNDS DEPARTMENT i io " .r SUPERINTENDENT AND ENGINEER "'•,,.o•1•" JOSEPH J. BORGESI --- �-44CHt)) I ' TELEPHONE 687-7$6�—ram~ September 9, 1985 Michael Roberts , Chairman Planning Board 120 Main Street. North Andover, Ma.. 01.84.5 =re .: Shannon7Lan7(e ) Dear Mike: At the request of Coo.l i.dge Realty Trust, we have estimated that a bond amount of $20,000.00 is necessary for the completion of water mains and appurtenances on Shannon Lane, Very truly yours , BOARD Off` PUBLIC WORKS J. William Hniur.cia.k Staff Engineer JWH: I b f E , OFFICE OF HIGHWAY SURVEYOk * , 384 OSGOOD STREETIL -- °* TOWN OF NORTH ANDOVER, MASSACHUSETTS 01845 �+ATG°At 1SS{C 1{UStt WILLIAM A. CYR TELEPHONE 685.0950 Highway Surveyor September 9 , 1985 Planning Board Michael .Roberts , Chairman 120 Main Street North Andover ,,, Massachusetts Re : Shannon Lane Bond Amount Dear Mike ; l would recommend the amount of $60 , 000 .00 (Sixty Thousand Dollars and No Cents ) , be used as a bond amount for this subdivision . This includes all items that come under the jurisdiction of the highway Department . Sincerely , William A. Cyr Highway Surveyor WAC/cc a o FP 30M PLANNING BOARD t .d