Loading...
HomeMy WebLinkAboutAndover Consultants Letter re Wetlands - Correspondence - 0 WINTER STREET 10/24/2023 '97audover I East River Place consultants Methuen,Massachusetts 01844 TeL(978)687-3828 xrw"r.andoverconsaltanis.com October 24, 2023 Mark Johnson, Esquire Johnson & Borenstein, LLC 12 Chestnut Street Andover,MA 0 18 10 RE: Vacant Parcels on Winter Street North Andover, Mass Parcel IDs: 104-I10, 104-149, 104-150 Dear Attorney Johnson, Andover Consultants has prepared the responses below to an abutter email sent to Jennifer Battersby dated October 9, 2023 regarding the above referenced project. The abutters comments have been-reproduced below in italics with our response following in bold. Lot 13: Comment: The majority of the house is within the 100'Buffer Zone Response: The proposed dwelling is within the 100' buffer zone,and as such a filing is required to be made with the Conservation Commission,which will be done following the issuance of a decision from the Zoning Board of Appeals. Comment:Approximately 35% ofthe driveway is within the 100'Buffer Zone. Response: 1,343 sf of the 3,742 sf driveway shown on the preliminary plan prepared for Lot 13 is within the 100' buffer zone(t35.9%)which is allowed under both the Town of North Andover's Wetland Bylaw and the Massachusetts Wetland Protection Act. A Notice of Intent will be submitted to the North Andover Conservation Commission as is required for work within the buffer zone. Comment: The drywell is within the 100'buffer zone. Response: Drywells are allowed within the 100' buffer zone. Comment: The majority of the driveway is too close to the neighboring property and not ivithin the setback line. Response: The side setback applies to structures, not driveways. The driveway was located to maximize separation from the from the resource area. Lot 14: Comment:A portion of the house is within the 100'Buffer Zone. Response: The proposed dwelling is within the 100' buffer zone,and as such a filing is required to be made with the Conservation Commission,which will be done following the issuance of a decision from the Zoning Board of Appeals. Comment:Approximately 55%ofthe driveway iswithin the 100'BufferZone Response: 2,389 sf of the 4,085 sf driveway shown on the preliminary plan prepared for Lot 13 is within the 100' buffer zone(±58.5%)which is allowed under both the Town of North Andover's Wetland Bylaw and the Massachusetts Wetland Protection Act. A Notice of Intent will be submitted to the North Andover Conservation Commission as is required for work within the buffer zone. Comment: The drywell is within the 100'buffer zone. Response: Drywells are allowed within the 100' buffer zone. Page I U2 Civil Engineers•Land Surveyors*Land Planners P:t22122S9WocsVetterst2023.10.24_Wintei StreeL Cashman.doc �� »ndover consultants ina Lot 1 S: I have a completely different set of concerns with lot 15, The lot itself does not meet the street fi-ontage requirements and based on the terrain and location of the 100'Buffe Zone, the proposed location of the home and driveway are on/within higher elevation. How can a home, driveway, septic system, and drywell be built on top of a hill without causing significant disruption to the surrounding homes, wetlands, and more Blasting damages homes and affects the water table and will very likely cause issues for years to come. My home is within the F&MA Flood Zone (Zone A) and I am deeply concerned with any changes or disruption to the water table. I am against building within the wetland surrounding my home (and all ofNorth Andover) and even more concerned when the proposed lot don't meet current zoning laws. The threat of water and flooding is real and only getting worse. Current zoning bylaws and wetland protection are in place to protect residents and prevent catastrophic damage caused by the changing landscape. If the zoning board approves these variances, it will cause additional issues as climate changes continues to impact us all. Response: All permits will be submitted for and obtained to ensure all applicable regulations(i.e.wetlands, septic system, blasting)will be submitted for as necessary to ensure compliance with local and state regulations. Though the three lots before the Board are not subject to the Massachusetts Stormwater Standards,as these standards do not apply to single family houses or to housing development projects comprised of detached single- family dwellings on four or fewer lots,each lot has been proposed to infiltrate roof runoff into a drywell and driveway runoff into a crushed stone infiltration trench. These features have been included to mitigate stormwater runoff and to promote stormwater recharge on site. If you have any questions concerning the above responses, please feel free to contact me at your convenience. Sincerely, Andover Consultants Inc. r r. 1, ", i (.C.£-o n Dennis A. Griecci, P.E., LEED AP Page 2 of 2 P;12 212 2-5 81d.eV.K-%2023,10,24 W,nte Sh,LCesh—d. DRIVEWAY -WINTER 1 T� f//-FINISH GRADE 4.yE� _ �i BO;fpRD YA / •I.. Ir S�Z S<pG�- NORM a4001{q.YA��_-._ STREET I11 a6' 6'7 77 5'E— 3567 T/'E 76.20' S4 0 N wN1FN noao N� FILTER FABRIC S2 25`� 3/4'TO 1-1/2- ` SITE CRUSHED STONE �' 2' / / C DRIVEWAY INFILTRATION TRENCH _! / i/ '. ✓ NOT TO SCALE PROPOSED 15' W4DE DRIVEWAY (4,256 S.F.) �m o POTENTIAL — REM ovE COVER AT LOCUS PLAN SCALE: 1"=800' 2'X2'DRIVEWAY SEPTIC ACCESS OPENINGS INFILTRATION SYSTEM \ 2-'DIA INSPECTION COVER NON-WOVEN GEOTEXTRE TRENCH L=216' '- OCATION FRAME de COVER TO GRADE(SEE PLAN) L TOP&SIDES 35 NOTE 1 rAx +z > 1 _ 35 PER NORTH ANDOVER WETLAND REGULATIONS, PROPOSED `� i NO DISTURBANCE IS ALLOWED WITHIN 25' OF 4-4EDRo0M INLET INV-VARIES A WETLAND, NO STRUCTURES ARE ALLOWED 1,000 GALLON OWEWNG ` SEE PLAN WITHIN 50' OF A WETLAND, ANY WORK WITHIN Y OR "JUMBO' E L B0 .. 50 1 Q U 100' REQUIRES THE FILING OF A NOTICE 2 to' O 0 0 O O C OF INTENT. 0 0 @ @ 2•12• C C j /' BOTTOM ELEVATION LOT 1 3 2 ��/ ��I`_ DRAINAGE HOLES 4-TO 21/2-CIA TAPER OWNER OF RECORD: 45 8&7 S.F. '<;' z vi/ CRUSHED STON ED LISLE WASH _�1-1��a J M CASHMAN ET AL, TRUSTEES OF THE ODELLE F. GASMAN TRUST OF JULY 12, 1986 907 DALE STREET SHEA PRECAST CONCRETE NORTH ANDOVER, MA 01845 1000 GALLON JUMBO DRYWELL ASSESSORS: NOT TO SCALE TOWN MAP NO. 104 LOT NO. 110 / r PRELIMINARY SITE PLAN—LOT 13 `< WINTER STREET NORTH ANDOVER, MASS. PREPARED FOR: ELLEN CASHMAN ZONING SUMMARY TABLE — DISTRICT Rt DATE: AUGUST 15. 2023, REV.: OCTOBER 24, 2023 SCALE:1"=40' REQUIRED EXISTING PROPOSED COMMENT LOT AREA 67,120 S.F. 45,887 S.F. 45,887 SF. VARIANCE MAY BE REQUIRED C.B.A. 65.340 S.F. 43,150 S.F. 43.150 S.F. VARIANCE MAY BE REWIREDA Andover AREA OUTSIDE 65.340 S.F. 16,49Z S.F. 16,492 S.F. VARIANCE MAY BE REQUIRED "' ttI'BUFFER ZONE consultants ` �' FRONTAGE 175' 185.47' 185.47' 1n C• \ E:c FRONT SETBACK 30' N/A 198.1' 1 East River Place SIDE SETBACK 30' N/A 35.1'/34.9' Methuen, Mass. 01844 Dennis A. Griecci REAR SETBACK p' N/A 114.0• Telephone:978-687-3828 Reg. Prof. Engineer HEIGHT 35' N/A ( 33' 0 40 80 120 160 Ft. P:\22\22-59\DWG\SITE PLAN.DWG 6 10 20 40 Meter _1r 1 UrcE DRIVEWAY FINISH GRADE WINTER STD ^ a rc.gr 7•1 N wNiCR N� POM -- S53b61 20.32 FILTER FABRIC ` cxusHEO STONE SITE t25� .•" < fir/;mil/Y-yr � L .r1' �HR,P y a DRIVEWAY P INFILTRATION TRENCH NOT To-SCALE "��y/✓ fAFfl PROPOSED IS' u A NtDE DRIVEWAY (4084 SF.) in LOCUS PLAN SCALE: 1"=800' m � REMOVE COVER AT ACCESS OPENINGS 2'X2'DRIVEWAY 2-'DIA INSPECTION COVER INFILTRATION F k(COVER TO NON-WOVEN GEOTEI(TILE POTENTIAL ; .TRENCH L=230' RAMS ( ! SEPTIC FRAME SEE PLAN) TOP SIDES 3. `,\ SYSTEM LOCATION t" TAPER _ ` NP�..NORTH ANDOVER WETLAND REGULATIONS, NO DISTURBANCE IS ALLOWED WITHIN 25' OF Ta A WETLAND NO STRUCTURES ARE ALLOWED ' - T 1A, INLET INV-VARIES 355' }5.5 i 4SEE P WITHIN 50' OF A WETLAND, ANY WORK WITHIN y OO �p Qp Qp 700' REQUIRES THE FILING OF A NOTICE PROPOSED -„. Qp Qp O OF INTENT. D2O OOz z NO _a BOTTOM ELEVATION ,/y // Tc 3•�(..,_ OWNER OF RECORD: /N DRAINAGE NOTES 4•TO 2 1/2•D1A TAPER /1000 GALLON J M CASHMAN ET AL, TRUSTEES OF THE / ,SHEA aIMBo• a /'- y /�" ,�� DOUBLE wA5xE0 t'-t}"®� FRANK CASHMAN REALTY TRUST >�� �oRY w/tLL CRUSHED STONE 849 DALE STREET y /s / "j / NORTH ANDOVER, MA 01845 LOT 14 =, SHEA PRECAST CONCRETE ASSESSORS: i 431,847 S.F < , 1000 GALLON JUMBO DRYWELL TOWN MAP NO. 104 LOT NO. 149 66 NOT TO SCALE 15so0 N56; << N5629S9w PRELIMINARY SITE PLAN—LOT 14 WINTER STREET i NORTH ANDOVER, MASS. PREPARED FOR: ELLEN CASHMAN DATE: AUGUST 15, 2023, REV.: OCTOBER 24, 2023 ZONING SUMMARY TABLE - DISTRICT R1 SCALE:1"=40' REQUIRED EXISTING PROPOSED COMMENT �. LOT AREA 87J20 S.F. 43.847 S.F. 43,847 S.F. VARIANCE MAY BE REWIRED / , C.B.A. 65,340 S.F. 41,976 S.F. 41,976 S.F. VARIANCE MAY BE REWIRED \andover (f 'u AREA WTSIDE 65,340 S.F. 9.321 S.F. 9,321 SF. VARIANCE MAY BE REWIRED xisBUFFERZONE onsultants , /-I- RONTAGE 175' 150.00 150.00' VARIANCE MAY BE REWIRED in (�i. f\\\ f f FRONT SETBACK 30 N/A 209.4• 1 East River Place , t YL " s0£s£BACK 30' N/A 35.7'/35.6' Methuen, Mass. 01844 Dennis A. -Griecci REAR SETBACK 30' N/A 83.5' Telephone:978-687-3828 Reg. Prof. Engineer HEIGHT 35' N/A }} 0 40 80 120 160 Ft. P:\22\22-59\DWG\SITE PLAN.DWG 6 10 20 40 Meter WINTER DRIVEWAY FINISH GRADE .0 7^E ST-_REE7- A eoxraRp S AA'Do1 11000 GALLON .. `��, ^,r• � (V ��'�Q-� � m< SHEA JUMBO e. NY WELL o FILTER FABRIC aoM Sr 3/4'TO 1-1/2' CRUSHED STONE SITE YT. - PROPOSED 15' � .� � WIDE DRIVEWAY (��,f $z ' (2.003 S.F.) PROPOSED A" 4-BEDROGM DWELLING 2'X2 DRIVEWAY DRIVEWAY 3 INFILTRATION �' o ' TRENCH L=1Qa' INFILTRATION TRENCH NOT TO SCALE � h "POTENTIAL ¢ SEPTIC F SYSTEM a .\ LOCATION ` "?sJ• £ LOCUS PLAN SCALE: 1"=800' ^f COVERREMOVE RECESS OPENINGS . q� -- ------- r - 2 DIA INSPECTION COVER NON-WOVEN GEOTEXOLE FRAME h COVER T TO P LOT 15`" `-- GRADE(SEE PLAN) 528 S.F. - 3 `' _ `:; k SIDES PER NORTH ANDOVER WETLAND REGULATIONS. _ - -PER NO DISTURBANCE IS ALLOWED WITHIN 25' OF z nm:v A WETLAND, NOSTRUCTU ARE ALLOWED 1 TA w m 4 .TOP - INLET INV=VARIES 00'(REQUIRE WETLAND, WITHIN THE FILING OF A NOTICE / � SEE PLAN OF INTENT. IN 7 i 2•_10 0 0 0 0 `2" OO T BOTTOM ELEVATION l OWNER OF RECORD: JOAN F. CASHMAN, TRUSTEE OF THE . N5T'�✓ \ .`, oo \ 3"+F— DRAINAGE HOLES 4"TO 2 1/2"DIA TAPER JOAN M. CASHMAN REVOCABLE TRUST DOUBLE WASHED 1'-11'a DALE STREET NO CRUSHED STONE 849 NORTH ANDOVER, MA 01645 rg pl ' � ASSESSORS: ��� //j; SHEA PRECAST CONCRETE TOWN MAP NO. 104 LOT NO. 150 1000 GALLON JUMBO DRYWELL } NOT TO SCALE PRELIMINARY SITE PLAN—LOT 15 WINTER STREET NORTH ANDOVER, MASS. PREPARED FOR: ELLEN CASHMAN ZONING SUMMARY TABLE - DISTRICT R1 DATE: AUGUST 15, 2023, REV.: OCTOBER 24, 2023 SCALE:1"=40' REQUIRED EXISTING PROPOSED COMMENT .y LOT AREA 87.120 S.F. 64.528 S.F. 64,528 S.F. VARIANCE MAY BE REWIRED C.B.A. 65.340 S.F. 64.381 S.F. 64.381 S.F. VARIANCE MAY BE REWIRED +and over $. AREA OUTSIDE fi5,]40 S.F. `10.888 S.F. 40,888 S.F. VARIANCE MAY BE REWIRED con--sultants �/..II BUFFER ZONE )n FRONTAGE 175' 150.00' ISO.00' VARIANCE MAY BE REWIRED Methuen,River Place Mass. 01844 ''\ yp FRONT SETBACK 30, NIA 60.7' 1 East n SIDE SETBACK 30, N/A 36.5'/36.3' I Dennis A. Griecci Telephone:978-687-3828 Re Prof. Engineer REAP.SETBACK 30' N/A 199.7' 9 9 HEIGHT 35- N/A 1 33' 0 40 80 120 160 Ft. P:\22\22-59\DWG\SITE PLAN.DWG b 10 20 40 Meter