Loading...
HomeMy WebLinkAboutApproved Septic Letter - Correspondence - 280 GRAY STREET 9/20/2024 i North Andover Health Department Community acid Ecanaaraic Development Division Sep"iteaiaher 20, :2024 Tarniekaa l la.aiater 280 Gray Street North Andover, MA 01 45 Re: Subsurface Sewage Disposal S stenaa flan for 2811 Goray Street (Mal) 1 Q71) Lot 124' Dear Ms. 1lunter: The proposed onsite wastewater systeaaa design plan fior the above site dated 8/12/24 with as fitnal revision date caf 8/2 /24 has been approved for issuance of as L)islaaisal Systetia C:`airastraaetiOn l'ertnit (l:)S(',P). Once issued, a [)SC-P will aaathcarire the construction of the onsite wastewater system per the plan referenced above and as allowed aan,der`["itic 5 of the MassaaclacoscIt:s F"nvirc'nnieaatal (lode, (310 CMR 15.000). YOU will need invcilvernerit frcai a the designer of"the onsite Wastewater system throe hOLIt the installation pr(,)cess so you should he snare to coordinate with them. The design has been approved COI- use in the construction cifan upgrade on-site wastewater system fcir aa, -bedroorri (iria xiraauaa) 11-room) hcirrae utilizing the existing septic tank and as proposed standard stone-and-pipe sail absorption system as indicated on the design plan. J'his design plan approval is valid for 2 years fTorn the above date, 1)uring this time, as licensed septic systeaia installer should obtain a pierraait and cortililete this vvork, and as Cea%tificaate of C onipliaarace be endorsed by the installer, designer, and the Town own oaf North Andover, 1ftliese activities ore not coiialal.eted within this tinie period theca it, is possible as new design plan will need to be conil:ileted and sa:Knitted fbr review. In the event an itrnriinent health lirobleaa such as sewage Nickup into the dwelling is occurring the North Andover Board cif l le,aa.lth ayiaay reduce the tiarie period for which this lalaaa is valid. Pape 1 of`3 North Aiicl.ovetr 1-leaalth Departrneait, Towaa Liaall, 120 Main Street North Andover, Mrs 01 45 Plione. 978.688.9540 Fax: 978.688. 9542 '['his approval is suIjject to the f'ollowing Conditions. Please be sure to review these with the designer and installer. prior to the issuance oCa Disposal Systeirt Construction, Permit: a. Three additional paper copies of the design plan are to be provided to the office b. The area of the proposed Soil. Absorption System (SAS) is to be staked and flagged to identify the location(s) and to prevent activities which might darnage the soil absorption systeni. Stockpiling of materials and equipment within the SAS arca is prohibited 'Throughout the project: a_ It site conditions are fOUnd in the field to be different from those indica,.ited oil (lie design plan, installation ofthe onsitc wastewater system shall stop and the designer and this office notified within 24 hours la. If is present at the bottom portion ofthe excavatiori for the soil absorption systern (SAS) the excavatioli is to be dewatered prior to the placement ofarly fill. No fill is to be placed for the SAS (,hiring rain or snow storms. Prior to placement ofar)y needed fill it) the SAS, the bottom is to be searified and relatively dry and the fill material is to be stockpiled at the edge ofthe excavationi and filled in gil-adually c, Inspections are to be performed by the designer of tlie otasite wastewater system as needed to properly oversee and docurnellt COnStRICti011. At as rninitnuin these are the initial excavation, prior tea backfilling, and during backlilting as well as any other component of the construction which the designer wishes to emarnine d. Inspections are to be completed by the Town of North Andover at a rninimurn as follows: i. fled bottom ii, 1'ank bottom �iii. Final, installation of components, confirn,iation, of'proper component selection, examination of construction inethodology, and system operation iv. Final grade v. Sand fill will be collected frorn at least one location arid analyzed for compliance with specifications in 'Title 5 e. No coniponent's are to be covered until as final corriponent inspection has [teen. completed C. No excavation for or work associated with construction ofthe soil absorption system is to occur ftorri November 30 to April I After conMruction: i,). Within 30 days ol"completion of construction the, installer and designer are to confirryi iffhe installation Nvork was cotnpleted in compliance with tbe design plan referenced in the DS("''P and with 'I'ille 5, and it,'so shall, certify this on a Certificate of Compliance form la. If'changes have been made to the approved plans then preparation ofan as-built pl,ln is required to be compteted by the designer. Ifrio changes have been made Ilage 2 ot'3 North Andover Health Department, Town Hall, 120 Main Street, North ,Andover, MA 01845 Phone: 978.688.9540 I`ax: 978.688. 9542 to the aPproved plans then the approved plan shall be modified by [lie designer to show the distances from as knowil StIlletUrC to the systeiri componen(s. i. No sewage shall be disclutrged to the oirsil.e wastewater system until a (",ertificate of Compliance has been issued by this office In addition, you should be aware of the Iong-term operation f-,,,uidelines of ari onsito wastewater systern (diese are riot part of the DS( 1) but, are mentioned below as info.-)rrnation for tire property owner): 1. An misite wastewater systern can function as an integral part ofthe infnistructure of the properly if it is properly operated and nraintained. Jbis is the responsibility of the owner of the property and is generally not specified by regulation. YOU are encouraged to contact a wastewater systern pumper/service provider lo partner with you to implement steps needed to assure the longevity of the onsite wastewater systern being installed zit this location The issuance ot'a DSCP does not construe and/or imply compliance with any perinits, approvals or licenses which might be needed from other agencies SUCII as the Conservation C ommission, Zoning Board, Planning Board, lluildinl.), Inspector-, Pkinibing Inspector and/or IJectrical Inspector. Please feel free to contact the office with any cluestions you may have. We look t`orward to working with YOU, to obtain a wastewater treatment and dispersal systern which will be in compliance with, all regUlations and assure protection Of pUblie health and.the environment, of North Andover. Sincerely, ram' l3ria J. I,aGrasse, Cf,' IT Director of"Public, I fealth. F.nel. Installers list cc: Vladimir Nenichenok, P.E, File P,tge 3 of'3 North Andover Health Department, Town Hall, 120 Main Street, North Andover, MA ()1945 Phone: 978.688.9540 Fax: 978.698. 9542