HomeMy WebLinkAboutSeptic Application for Installation - 850 Johnson St - Application - 850 JOHNSON STREET 7/24/1958 �` r • ~ . . :< , t t , f. ,. Arthur Kent
0616 Johnson St.
APPLICATION FOR SEWAGE DISPOSAL INSTALLATION t'
HEALTH DEPARTMM-»NORTH AIMOM, MASS.
I hereby make application for a permit for a sewage disposal installation at
Johnson St. , I will install this system in
accordance with all the laws of the Commonwealth of Massachusetts and regulations
of the Board of Health of the Town of North Andover.
Furtherp I will construct the house sewer of bell and spigot pipe, the minimum
diameter being 4 inches'. and will maintain a minimum grade of 1,e) until 10 feet
preceding the septic tank# where the grade shall not exceed 2%. I will install a
concrete septic tank of ZLLO- E.a.1.t....,.. in size. A manhole (s) permitting easy
cleaning will be provided with removable cover (s) of iron or concrete within 12
inches of the ground surface. I will provide subsurface disposal field with open
jointed bell and spigot Ackron pipe at Least 4 inches in diameter and laid in a
series of trenches, the bottom of which will provide a minimum of 125 lineal
(ROM) feet of effective absorption area. The pipes will be laid on a 6 inch
layer of washed gravel or crushed stone ranging in size from 3/4 to 1-1/2 inches
(dia.) and the pipes will be surrounded by similar material to a height of 2 inches
above the crown of the pipe. The joints of these pipes will be protected from
clogging and before filling the trench,` 2 inches of gravel or stone 1/811 to 1/4"
(dia.) will be placed over the course gravel or stone, The disposal field will. be
installed at a grade of 4 to 6 inches/ feet. No single the line will exceed
100 feet in length and in any case, two lines of the wiU be installed. A minimum
of 6 feet will be maintained between the center lines of the disposal field trenches
and the average depth of trench shall not exceed 36 inches. No part of the in-
stallation will be less.than JOG feet from any private water supply, 25 feet from
any stream, 20 feet from any dwelling or 10 feet from any property line. L_ftf ther
agree not to Bove „anr_2gjftion of this installation until-a roved by the inspection
officer, as provided belows and to incorporate any additional requirements that
may be attached to the permit. Plot Plans must be submitted with application.
r
DATE t ._
Signature of Applicant
I hereby issue the above permit for the Board of Health of the Town of North
Andover, Massachusetts.
DATE X�� cry
Si nature of Health Agent
I have inspected the uncovered system indicated above and find everything dons
as described.
DATE ��� 2 J �..
Signature of specting Officer
Percolation Test 2 min.