HomeMy WebLinkAbout1981-12-21 Correspondence DEF SUB FORM L
REFERRAL FORM
-006MMY/Def initive Plans
North Andover) Massachusetts Jr
L C 9 99
Highway Surveyor
Supt, of Public Works jo
Conservation Commission
Building In
spects
Fire Chief
Police Chief
Tree Warden
Subdivision Control Subcommittee
L4,4
The attached -kwim*==6=mry-/definitive plane were submitted to the Planning
Board on C
J,
A public hearing has been/\scheduled for P.M. on Lk fL e- -,,:),,3
to discuss these plans.
May we have your comments and recommendations concerning this subdivision
, q
by no later than I �, _ I Please return this
form with your comments and recommendations.
Thank you#
Clerk# PLANNING BOARD
RAYMOND J, CANTY, CHAIRMAN JOHN fJ. THOMPSON JAMES D. NOBLE, JR- CLERK
TOWN OF NORTH ANDOV ER, MASS.
0
BOARD OF PUBLIC INORPHS
WATER, SEWER, PARK, PLAYGROUND AND SCHOOL GROUNDS DEPARTMENTS
SAC,4US't SUPERINTENDENT AND ENGINEER
JOSEPH J. BORGES1
TELEPHONE 687-7964
November 20, 1981,.
M.r. Patil. Hodstrom, Chaixma-11
PInnning Board
120 Main Qrop'q Mass . OM'
TQ.` Ingalls Crosal"'11p, TIT
Dear Paul :
In reply to your letter of October 29, 1981 concerning the
definitive subdivision plan of Ingalls Crossing 111, we have the
following .y.-(-.,!commnnda t ions to make :
We estimate the coat of an eight inch ductile iron cement lined
water pipe (Class 52) seal coated inside, to coated outside on
Laconia Circle at $25,000.00. This is for 1311 feet of eight inch
pipe installed fifteen feet from the property line with five feet
of cover below the finish grade of the street, Eddy breakflange
hydrants to North Andover Specifications are to be Installed at
stations 6 + 50, 10 + 70, and 15 + 05 at the property line, An eight
inch Mueller or equal gate valve (open left) will be required at station
10 + 0.
We estimate the cost of an eight inch ductile iron cement lined
water pipe (Class 52) seal coated inside, tar coated outside oil
Kelefa Road at 1332000.00. This in for 1670 feet of eight inch pipe
installed fifteen feet from tho property line with five feet of cover
below the finish grade of the street. Eddy breakfLange hydrants to
North Andover Specifications are to be installed at stations 0 + 30,
4 + 85, TO 4- 50 and 16 •+ 30 at the property llno� Three eight inch
Mueller or equal gate valves (open left) will be required at the inter-
section of We& Road and Taconla Circle and one eight inch gate valve
will be required at the intersection of Kolofa Road and Forest Street,,
We estimate the cost of a twelve inch ductile iron cement lined
water pipe (Class 52) seal coated ine-1do, tar coated outside on Forest
Street to the centerline of lot 30 a&6, 700.00. This is for 270 feet
of twelve ,inch installed fifteen feet ' from the property line with
five feet of covor below the finish grade of the street. A twelve inch
Muelfor or equal gate valve (open loft) will be required at the inter-
section of Kelefa Road and Forest Stroot.
A] 1, hyd-rants si:aaa.a:l.c) be installed with six :i raci! Mueller or cagaa.al.
g t o valves, All gait o val.vf n shall comply wi-th AWVA Specifi.eati.ons
L500 2T nud be equipped with sliding ;=yp'A cost Ann gate boxes mral: ed
"WATER".
All of the nbove work f1li st pass Leakage and pressure ure tests performed
in ac..c or.c3nxaen with SpeLion 13 AWWA. Standard C600 and shall he chlorinated
in accordance with AWWA C601. Standard Proc.,rcir.r.re for Disinfecting Water
h ins
Adrrilvat v public c, l nbi.l ty and property dal-1 tge insurance, a street
ee
of\
1:'r l
{3f)d'.11';ling permit mi_i ,i_"om t��'v I\�().r, h A�"!.t"(s7� o-r rY ! t��; w 3 � � rt:mnnt: ,1J'd a [knt ei"
main instN t.nv I_on pC?'W"11 it Nom the 13onrd of PaY,blia Works will be required
before any construction begins .
Very truly yours ,
TIRARD OF PUBLIC WORKS
V,
Sol .. J. orgo i 5tpt
113a1 �
yyORTH q
=n` OFFICE OF HIGHWAY SURVEYOR
*s * 384 OSGOOD STREET
TOWN OF NORTH ANDOVER, MASSACHUSETTS 01845
sacHus���
WILLIAM A.CYR TELEPHONE 685-0950
Highway Surveyor Nov. 23, 1981
Paul. Hed.strom, Chairman
Planning Board.
120 Main St.
North Andover., Ma.
Red; Ingalls ill
.............
Dear au..
I have gone over the plan for the proposed sub-
division and make the following comments & recomm-
endations,
I would first mention that there is an error on
the hottop thickness. It should be 2" of binder and
1p it of top.
I have no problem with the drainage design as
,shown on the plan except; the MAP oval pipe that;
is proposed between stations 08. I' would recommend
that; this pipe be a Class 4 36" R.C.P. with a minimum
cc, ver dept of 3 ft.
Cape Cod Berm will be required on portions of this
subdivision. Gravel and hottop widths would be widened.
by )i ft. in these areas, to be determined in the field.
Any drainage problems encountered in the field and
during construction would be en.corporated into the
drainage system and shown on the as built plan.
Catch basin units to be 8" precast concrete units
with cone tops, 4 :flange 6" checker board type frames
and grates to be used.
All drain .ripe to be reinforced concrete. Sub drains
required when and where necessary, to be determined in
the: field, by the Highway Surveyor.
Drainage easements to be deeded to the ` 'own and
recorded by the developer.
r,
5 ,
Ingalls TIT P. 2.
Siltation and erosion plan to be submitted along
with a maintenance plan.
Driveway entry permits to be obtained before any
driveways are cut out.
Inspection permit to be used as specified.
No drainage, hottop or utility work will be
performed between the first of December and the first
day of March, unless such work would be of an emergency
nature and this would require a special permit issued
by the Highway Dept.
I will be at your meeting Monday evening to answer
any additional questions that might arise®
Very truly yours,
William A. Cyr
Highway Surveyor
WAC/m.