HomeMy WebLinkAbout1986-02-10 DEpartment Review DEF SUB � � w—� �w—WwwW�� wwWWw�mmw CENTRALn FIRE 1­1EA1DQUA1F4TERS 124 Main Street P � 9`�ortl°o Andover, Mess. 01845 5 t) C hie,t of Department To: No. Andover Planning Board From: Fire Chief Dolan Re: Jerad Place Date: December 16 , 1985 I have reviewed the plans for "Jerad Place" and have the following comments and recommendations : 1. In order to eliminate any confusion, the name Jerad Place is not necessary. The road is a continuation of Candlestick Road and should be so named. 2 . Hydrants should be located every 500 ' at a spacing from the last hydrant on the present Candlestick. 3 . An additional hydrant should be located at the new Cul-de-Sac until the continuation of the street is made. 4. Permanent house numbers shall be posted on dwellings prior to occupancy. 5 . No open burning is to be permitted except during open burning season under fire department regulations. 6. All builders must comply with the fire department underground fuel storage regulations . 7 . Prior to taking occupancy, the subdivision streets shall provide adequate access to each residence by having had the binder coat applied. 8 . As a matter of public safety to the future residents of these dwellings and to decrease any possible liability to the town, I urge the planning board to require that no temporary occup- ancy permits be allowed. William V. Dolan, Fire Chief R -m. CEN 1"RAL. FIRIE HEADQUARTERS 14 Main Street North Ar Uf WPL.k. IAM11 V. DC"LA f "rel. u 3 '"1 Chief of Department To: No. Andover Planning Board From: Fire Chief Dolan Re: Environmental Impact Statements ' Date: December 18, 1985 In reviewing plans and reading the accompanying environmental impact statements, I have noted a consistent practice be persons submitting the information with regard to how a proposed sub- division will affect the town and town services . It appears common practice that the statements confine themselves to the subdivision being presented that they do not give a true picture of the impact for an area. For example, if a person submits a small six lot subdivision and states that these six houses will have minimal impact on the town, he is correct. But if that six lot subdivision is in an ,area where there are other subdivisions, the six lots combined with the other subdivisions should be taken into consideration. It is particularly interesting to me when an individual who presents the statements for several subdivisions in the same genral geo- graphic area chooses a "tunnel vision" approach to the particular subdivision he is presenting to your board, without regard for the other subdivisions. To sum it up, although the environmental statements are being given, I do not believe they are as useful as they could be. The devel- oper or person representing the developer should provide a view of not only his individual project in an area but the relationship of that project with others in an area and the individual and the combined affects these projects have on an area both positive and negative. Please contact me if you have any questions of me regarding this matter. OF William V. Dolan, Fire Chief NNINamn G , TOWN OF NORTH ANDOVER, MASSACHUSETTS OFFICE OF CONSERVATION COMMISSION OORT q TELEPHONE 683-7105 0 SA tJS TO : Planning Board FROM: Tracy A. Peter, Conservation Assistant RE: Jerad Place DATE: December 19, 1985 After a review of the Definitive Subdivision Proposal for Verad Place", the NACC requests that the Planning Board require the developer to file a Notice of Intent. In this Notice of Intent the NACC would like to review a justification for the two wetland crossings and the extent of the housing construction. F.0 rt ........... P�I�H� IH� BOI�f�O TOWN OF NORTH ANDOVER MAS SAC HU S ETT S f NORTH 1 's OOG O ,SS^CHUSEt December 24, 1985 Mr. Thomas Neve 447 Old Boston Road Topsfield, MA 01983 RE: Jerad Place Dear Mr. Neve: The North Andover Planning Board, in addition to several other departments, are in receipt of the definitive submittal of Jerad. Place off Boxford Street. , The Planning Board would specifically like you to elaborate on the Statement of Environmental Impact regarding Town Services, items one through seven; and General Impact. We would like the impact statement to be broader in scope beyond the subject area rather than confining the impact statement to the subdivision in question. The Board requests that you submit further detailed information on its' combined impact on the surrounding area and the Town as a whole, both positive and negative. The issue of further extension of this roadway should be discussed as well. We would }rrefer that this information be submitted by the public hearing on January 6, 1986. r , Please contact Karen Nelson if you have any questions regarding this matter. Sincerely, �r Michael P. Roberts, Chairman, Planning Board enc. cc: Robert Janusz f BOARD OF HEALTH 120 MAIN STREET A ED U NORTH ANDOVER, MASS. 01845 TEL. 682-6400 Dec 30, 1985 Planning Board North Andover Re : Jerad Place,Proposed Subdivision t4ass . Candlestick Lane Gentlemen: Ground water tests on the above listed property were witnessed in May, 1985 and appear to be favorable . Percolation testing has not been conducted as yet . Very truly yours , Michael Gra Health Inspector BOARD .PLANNiNG NORTH-ro%AjP4 OF WIN cJ 7 �1, OM,;a4JM'L:F Ihd'T h11 1 add 1" C)L,. 384 0 GOCK) STREET INSECT PEST CONTROL F y, NORTH AN DC)VER, MASS. TR WA1'3DEN rah "� T 01845 t I " SAC INSECT PUT CONTRU.. AND rFIEE DEPAR"I'MEN I' January 2, 19B6 l'lann:i.ng F3oard. "fawn. Office Building Oort;h Andover, Ma. Gentlemen: Re: Jerad Place Subdivision All requirements of the subdivision control laws pertain- ing to "Street Trees" shall k7e enforced by this department. I: would therefore recommend that bond money :in the amount of $6,800 be retained for this purpose. Very truly yours, � � � � pORT#j Of ttao r,'fib 3� OFFICE OF HIGHWAY SURVEYOR 384 OSGOOD STREET TOWN OF NORTH ANDOVER, MASSACHUSETTS 01845 �SSACHUS�t WILLIAM A.CYR TELEPHONE 685-0950 Highway Surveyor Jan. 6 , 1986 Michael Roberts , Chairman Planning Board 120 Main St . North Andover , Ma. 01845 Re : Jerad Place Dear Mike : I have reviewed plans and would make the following recommendations . 1 . Rest of Janusz land should be laid out on plan for possible future subdivision . 2 . Catch basins may be required at connection of new road to existing culdesac . 3 . Drainage should be extended to end of proposed culdesac for future connection. All house drainage directed to street area to be tied into drainage system. 4 . No manholes would be required in drainage except for angle points . 5 . Cape Cod Berm would be required where deemed necessary. To be determined in the field . 6 . Catch basin units to be 8 " precast concrete all brick to be clay brick . 7 . 18 " overlap of gravel on each edge of road . 8 . Binder coat of hottop to be 29 ft . . Finish coat to be 26 ft . I will be at your meeting Monday evening to discuss this further if you wish . Very truly yours , William A . Cyr Highway Sur veyor James D.Noble,Jr.Clerk John P.Thompson,Chairman Raymond J.Canly,r TOWN OF NORTH ANDOVER, MASS. 0 BOARD OF PUBLIC WORKS WATER,SEWER, PARK,PLAYGROUND AND SCHOOL GROUNDS DEPARTMENT SUPERINTENDENT AND ENGINEER •ol."t." JOSEPH J. BORGES1 SSACH TELEPHONE 687-7964 February 10, 1986 Mr. Michael Roberts , Chairman Planning Board 120 Main St® North Andover, Ma. 01845 re : Candlestick Road Dear Michael : The Board of Public Works has reviewed the plans of the proposed Jerad Place subdivision and have the following recommendations to make : 1 . The water main on Candlestick Road shall be 8" class 52 ductile iron water pipe, installed 10 feet left of the centerline of the road with 5 feet of cover below the finish grade of the street from the terminus of the existing water main to station 12 + 50� 2. Any 8" gate valve shall be installed at station 1.2 + 40. 3. Eddy breakfl,ange hydrants to North Andover specifi.- cations are to be installed at station 4 + 70, 9 + 50 and 12 + 50. 4. All hydrant branches shall be provided with six inch Mueller or equal gate valves (open left) . 5. All gate valves shall comply with AWWA specifications L500 52T and will be supplied with a 100 lb. sliding type gate box marked "WATER. " 6 . All water mains shall, pass leakage and pressure tests performed in accordance with section 13 of the AWWA standard C600 and shall be chlorinated in accordance with AWWA C601 "Standard Procedure for DIsinfecting Water Mains . Very truly yours , 7 BOARD UBLI WORKS J W V /XPj J.William H rciak )A A lb Staff Engineer A N TOWN OF NORTH ANDOVER, MASSACHUSETT OFFICE OF CONSERVATION COMMISSION f pORI"H N TELEPHONE 683-7105 41 y�SSAC`FI05�� September 4, 1986 Mr. Robert Janusz 40 Sunset Rock Road Andover, MA 01,810 Re: Jerad Place I, DEQE File #242-331 Dear Mr. Janusz: The North Andover Conservation Commission voted, at our meeting of September 3, 1986, to accept the Plan #S-305-7, by Thomas E. Neve, dated August 22, 1986 as per the requirements of Conditions #13 and 16. The Commission also voted to accept the plan #S-305-10 by Thomas E. Neve, dated August 21, 1986 and the associated drainage calculations for allowing the filling of a 1,450 S.F. isolated wetland on Lot #10. Sincerely, Tracy A. Peter Conservation Administrator cc: Thomas E. Neve, Assoc. Planning Board TAP/mlb 1 TOWN OF NORTH ANDOV R, MASSACHUSETTS DIVISION OF PUBLIC WORKS 384 OSGOOCD STREET, 01845 PAUL S. NIMANTELEPHONE 687.7964 DIRECTOR p40RTH FAX: (508) 683-9381 0� m May 17 1990 tc9 -13 imy fkNi,41NG 6, ,. Mr. George Perna, Chairman Planning Board 120 Main Street North Andover, MA 01845 re: Jerad Place I Dear Mr. Perna: The Division of Public Works has reviewed the progress of construction in the Jerad Place subdivision and recommends that a bond amount of $25,000 be retained to insure completion of work within the subdivision. Very ly yours, Q t. J. William Hmurciak Director of Engineering & Administration JWH:1b cc: Robert Janusz