RE.- NOTICE OF VIOLATION-Address/Map:Parcel ID 084.0-0028-0030.0
Avinash Muttamsetti
"Torn records indicate that you are theOwner(s)of this property and I am writing to notify you of an observed v l .tin ;
Basement bedroom with no smoke alarms or egress.
FOIE VIOLATION
U're alarms
2021 International Residential Code-Section R314 Smoke alarms
R314.3 Location. Smoke alarms shall be installed in the following locations:
1. 1n each sleeping room.
2. Outside each separate sleeping area in the immediate vicinity of the bedrooms.,
3, On each additional stogy of the dwelling,including baseinents and ha 'table attics and not including crawl spaces
and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels,a smoke alarm installed on the upper level shall suffice for the add acent lower level provided that
the lower level is less than one full store below the upper level.
4. Not less than 3 feet 14 mm horizontally from the door or opening of a bathroom that contains a bathtub or shower
unless this would prevent placement of a smoke alarm required by this section.
. 1n the hallway and in the room open to the hallway in the dwelling units where the ceiling height of a room open to a
hallway serving bedrooms exceeds that of the hallway by 24 inches 6 10 )or,more.
R3 0.1 IBC 2023 Emergency escape and rescue opening required.
Basements,habitable attics,and every sleeping room designated on the construction documents shall have not Less than one
operable emergency escape and rescue opening.Where basements contain one or more sleeping rooms,an emergency
escape and rescue opening shall be required in each sleeping room.Emergency escape and rescue openings shall open
directly into a public way,or to a yard or court that opens to a public way.
R I .2.1 Minimum Opening Area. Emergency and escape rescue openings shall have a net clear opening of not less than
.7.ft' o. 3on . fife net clear opening dimensions required by this section shall be obtained by the normal operation of the
emergency escape and rescue opening from the inside. The net clear height opening shall be not less than 24 inches
1 Omm and the net clear width shall be not less than 20 inches 50 ).
non-compliant work will need to be redone to meet modern codes.
The Building Department reserves the right to include additional inspectors and other Town of North Andover personnel as
necessary to verify compliance with the Building Code and Town Bylaws related to the Violation(s).
RLi GISTRY FILING
In the event that this Notice(s)is filed with the Northern Essex Registry of Deeds,we will provide you with a Letter of
Release upon receipt of monies,from.you,($125 per document),to compensate North Andover for the initial filings by this
Department.All costs to file/record such a Release shall be borne by the Applicant.
APPEALS
If you feel you have been aggrieved by these o�rders,you may file an appropriate appeal as follows;
1. Violations of tlie,,�"tate of Massachusetts Buildin may be appealed yin accordance with CM R 450,IRC
Ch.Rl 12 and/or IBC Ch.113 of the Code.Further information on Appeals through the State Department of
Public Safety/BBRS can be found at
littI2,; ,WwW. se-type/state-bu lRg-C�2�jlcals-board.html..
nias-s. s )ss/con!LunieL- lid-bus-lic/ficen Ild -,ode-,"
_wv/e,op
*Please note;Apimals 7nust be filed ivit1fin FOITY-Five(45)days of the date ofserWce of no ice, hereby or
throtigh registered ina .
CONTACT
If you sho�uld have any questions regarding the observed violation(s)or otherwise,please contact this Department at
(978)688-9545 during office hours posed on the Town's website at Nvw,w.northandoygmjgZa.
lo
Joel Bedard
North Andover Local Building Inspector
Craig DeCosta
North Andover Health Inspector