Loading...
HomeMy WebLinkAboutWiring Permit - Permits #13174-1 - 280 FARNUM STREET 3/9/2016 (3) i Date. � + ................ I i C�µowrH Yti TOWN OF NORTH ANDOVER m PERMIT FOR WIRING �CHUS� This certifies that V s C, ................................................_....... has permission to perform f) ....:€t,' r c, r ° €, T/- .... wiring in the building of.,.,, .......................... ..................... at North Andover,Mass. Fee.. ._.....Lie.No ELECTRICAL INSPECTQR Check# 1-3 3 �\ lnommoruveallh o�e�/771/a�nnae�rwe(fa Official Use f,Onl}y JJoParfnwnl o�Jire Jewicea Permit No. 1'J I Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS R9ev.1t07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRI,VT IN INK OR TYPE ALL INEOR 1,1ATION) Date: 3/712016 City'or Town of: North Andover To the Inspector of tVires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 280 Farnum St Owner or Tenant George Perna Telephone No. 978-973-8019 Owner's Address 280 Farnum St North Andover MA 01845 Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) Purpose of Building Rooftop solar installation Utility Authorization No. Existing Service Amps 1 Volts Overhead❑ Undgrd❑ No.of Meters _ New Service Amps ( Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a rooftop PV system:35 panels(9.625kW DC) Corsi letion o the follow+in table ma=be waived by the Ins ecto a Yfires. : No.of Recessed Luminaires No.of Ceil Susp.(Paddle)Fans No.o Total r Transformers KVA c No.of Luminaire Outlets No.of Hot Tubs Generators KVA SSSt No.of Luminaires Swimming Pool Above In- o.o Emergency rg mg C rnd. ❑ rnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and InitiatingDevices -31 No.of Ranges No.of Air Cond. Tons l No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons K\' No.o elf-Contained .... ......................................................... Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ umcipal ❑Other Connection No.of Dryers Heating Appliances KW See urity Systems: No.of Devices or Equivalent No.o Water K4V No.of No.of Data Wiring: Heaters Si ns Ballasts No.of Devices or E uivalent No.Hydromassage Bathtubs No,of Motors Total HP elecommumeations\Vinng: No.of Devices or E uivaleot OTHER: Solar Attach additional detail if desired or as required by the Inspector of F4"ires. Estimated Value of Electrical Work: $14,081.38 (When required by municipal policy.) Work to Start Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND ❑ OTHER❑(Specify:) I certify,under the pains and penalties ofperitoy,that the information or this plication is true and complete. FIRM NAME: Sunrun InstallationServices,Inc. LIC.NO.:21136 A Licensee: Nate Ashe LIC,NO.: 11361 B (Ifapplicable,enter"exempt"in the license ntanber tine.) Bus.Tel.No.: 978-549-9438 Address: 734 Forest Street,Suite 400,Marlborough,MA 01752 Alt.Tel.No.: *Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License: Lis.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent, Owner/Agent PERMIT FEE:$ i Signature Telephone No. A�® CERTIFICATE OF LIABILITY INSURANCE 1oA120 —E(M D YY THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements. PRODUCER CONTACT Arthur J.Gallagher&Co.Insurance Brokers of CA. NAME' PHONE .415-546-9300 FAc a.415-536-8499 1255 Battery Street#450 San Francisco CA 94111 E-MAIL INSURERS AFFORDING COVERAGE NAICp IN$URERA:Zurich American Insurance Com an 16535 INSURED SUNRINC-01 INSURER B Sunrun Installation Services Inc. INSURER C: 775 Fiero Lane,Suite 200 San Luis Obispo,CA 93401 INSURER D: NSURERE: NSURER F COVERAGES CERTIFICATE NUMBER:944362624 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, INSR POLICY EFF POLICY EXP IS TYPE OF INSURANCE INSD Me POLICY NUMBER NIMIDDIYYYY MMIDDtYYYY LIMITS COMMERCIAL GENERAL LIABILITY I EACH OCCURRENCE $ CLAIMS-MADE OCCUR DA A E T RENTED ' PREMISES(Ea occurrence $ i MED EXP(Any one person) S PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIESPER: I GENERAL AGGREGATE $ POLICY❑'P"a E'CC PRODUCTS-COMPIOPAGG $ I $ OTHER: $ AUTOMOBILE LIABILITY 7AGGREGMATE $ANY AUTO URY(P.,person) SALL OWNED SCHEDULED URY PAUTOSATOS (et accident) $NON OWN D A A EHIREDAUTOS AUTOS t $SUMBRELLA LIAB (OCCUR I URRENCE $E%CESS LIAB ICIAIMS-MADE j E S DED I RETENTIONS IS A WORKERS COMPENSATION Y 1WCp 13696001 tOfit2015 10/1/2016 X STATUTE ER A AND EMPLOYERS'LIABILITY YIN IWC013696101 0/1/2015 10f172016 ANY PROPRIETORiPARTNERIEXECUTIVE i E. EACH ACCIDENT $1,000,G00 OFFiCER-11BER EXCLUDED? ❑NIA j L. {Mandatory in NH1 ( E.L.DISEASE-EA EMPLOYE $1,000,000 If yes.deecdbe untler DESCRIPTION OFOPERATIONS below E.L.DISEASE-POLICY LIMIT $1 000,000 i i DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be afts—dif--pace is sq,i,d) WC013696001-$25,000 Deductible;WC013696101-FL,HI,MA,NJ,NY,OR,VA,WI only. Evidence of Insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of North Andover ACCORDANCE WITH THE POLICY PROVISIONS. 120 Main St North Andover MA 01845 USA AUUTHHOREED REPRESENTATIVE ©1988-2014 ACORD CORPORATION.All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD COMMONWEALTH OF MASSACHUSETTS BOARD Of ELECTRICIANS " ISSUES THE'FOLLOWING LICENSE AS A w REGISTERED MASTER ELECTRICIAN SUNRUN INSTALLATION SERVICES INC NATHAN,A ASHE 241 RIVERST EXT \ ` BILLERICA MA 01821-2344 ti6 c n7/it/16 i LLFR46 7T DRIVER'S LICENSE _ di lss vaa� asaxaaea i)646-2¢15 NONE S96911711 N08.30-2919 �08 3- �983 4 FtAss 12 FEST iS SEC M 1g14sf�4$` - 6M NONE zNATNAN'A w..a s241 RIVER ST EXT f ..... 81LLERICA,MA 01821 s aoasiezals Ravo�.ismas MA IIIIIIIIIIIIIIIIII11111111111111111111111IMIIII wvm.t,mss IsW vlrmv as.aaisea nwa cvas- D:Smai vahiN¢lozs Nan 2i,C01 Ihs,.exceplacFrooi 6�s. En4'YIftSEtR'cMS - REMCRONS NONE`- NONE CM.EOFAIXiRE55.PwarsELOW.FERtAgNEM w _ a SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION SYSTEM SIZE:9625W DC,70000W RC • ALL WORK SHALL COMPLY WITH 2O14 NEC,200918G,MUNICIPAL CODE.AND ALL SE SERVICE ENTRANCE SOLAR MODULES PV-1.0 COVER SHEET ( ,�...RAIL MODULES:(35)REC SOLAR:RE0275TP MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. t PV-2.0 SITE PLAN INVERTER(S): + PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O14 NEC. Fo� (1)SOLAREDGE TECHNOLOGIES:BE 10000A-US(240V) . ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O14 NEC. Mp MAIN PANEL PV-3.0 LAYOUT RACKING SNAPNRACK SERIES 100 UL;FLASHED L FOOT. + PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY °` PV-3.1 LAYOUT SEE PEN D01. GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SdIAREDGE RAPID SHUTDOWN REQUIRED • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL STANDOFFS& PV 3 2 RAFTER + IN CONFORMS TO AND IS LISTED UNDER UL 1741, FOOTINGS REINFORCMENT • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PV-4C ELECTRICAL STRUCTURAL UPGRADES REQUIRED: • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E)AND 2012 LC PV LOAD CENTER RAFTER REINFORCEMENT(ARRAY 3) IFC 605.11.2. S \ CHIMNEY PV-5.0 SIGNAGE • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. + 9.4 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ATTIC VENT 14.68 AMPS BERATED SHORT CIRCUIT CIRCUIT(690.8(a)&690.8(b)). FLUSH ATTIC VENT PM• DESIGN CRITERIA:SNOW LOAD=55 ESE AND WIND=110 MPH. DEDICATED PV METER PVC PIPE VENT STAGGER PENETRATIONS. INVERTER(S)WITH METAL PIPE VENT OF INV INTEGRATED DC DISCONNECT AND AFCI -- T-VENT PRUL K ZACHER AC AC DISCONNECT(S) $ STRUCTURAL ra, SATELLITE DISH _No_50100 o, `, DC DISCONNECT(S) ,f_ FIRE SET.A.KS XStpNALEN�' OBCOMBINER BOX t -' HARDSCAPE For Structural Only r� INTERIOR EQUIPMENT —PL— PROPERTY LINE LC J SHOWN AS DASHED SCALE:NTS sunrun A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER LICENSE NO.750184 VICINITY MAP COMECOMPOSITION_ DC DIRECT CURRENT (E) EXISTING EXT EXTERIOR CUSTOMER RESIDENCE FRM FRAMING GEORGE PERNA INT INTERIOR 280 FARNUM ST,NORTH LBW LOAD BEARING WALL 280 FAR R,MA,,NO MAG MAGNETIC 845 MSP MAIN SERVICE PANEL TEL _ (N) NEW ,ter: NTS NOT TO SCALE PROJECT NUMBER OC ON CENTER 221R-280PERN PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT DESIGNER; PV PHOTOVOLTAIC D.ALLEN TL TRANSFORMERLESS DRAFTER: TYP TYPICAL DI I V VOLTS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET A.1 REV:A.1 311t2016 ., -r PAGEPV-1,0 SITE PLAN-SCALE=1132"=1'-0" PITCH TRUE AZIM P(SOFT) ® AR-01 18' 68` 54` 337.06 AR-02 18' 68' 54' 302 AR-03 18' 158' 144' 35.8 AR-04 18' 338' 324' 106,44 AR-05 18' 15W 144' 35.8 AR-06 18' 248' 244' 70.96 vt PU ei / PAUL K. ZAGHER ct STRUCTURAL y U No 50OF100 7—(N)ARRAY AR-03 `DSIOryAL��'� PL (N)ARRAY AR-04 t (N)ARRAY AR-02 sunrun AZ (N)ARRAY AR 05 g > / e4 LICENSE NO.750184 IPA (N)ARRAY AR-06 CUSTOMER RESIDENCE: -'. GEORGE PERNA 280 FARNUM ST,NORTH ANDOVER,MA,01845 (E)RESIDENCE TES-- PROJECT NUMBER: 221 R-280PERN e+- (N)ARRAY AR-01 DESIGNER: D.ALLEN M DRAFTER: DI SE SM INV SHEET SITE PLAN REV.A.1 311/2016 PAGEPv_2 Q ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR-04 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS 2X6 8'-9" 16 NO N-O" 1'4" REC SOLAR:REC275TP AR-05 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS 2X6 8'-9" 16 NO 4'-0" 1'-4" MODULE DIMS: 65.5"x 39"x 1.5" AR-06 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS 2X6 T-0" 16 NO 4'-0" V 4' MAX DISTRIBUTED LOAD:3 PSF SNOW LOAD:55 PSF D4-AR-04-SCALE:3116"=1'-0" WIND SPEED: PITCH:18° t- 1 t'-2" 110 MPH 3-SEC GUST. AZIM:338" 6_2.. LAG SCREWS: — - 116"x4":2,5"MIN EMBEDMENT 6 5 3 ?- - - - - ;- — - £ PENETRATION SPACING: 56" j x 4'TY P—{ ' €�4'TYP— STAGGERED 7 i �ySH OF4t4S" PAUL K. 7_1 ZACHER STRUCTURAL y No.50100 SSK7NALFS��'\ sunrun DS-AR-05-SCALE:114"=1'-0" D6-AR-06-SCALE:114"=1'-0" PITCH:18' PITCH:18' LICENSE NO.750184 AZIM:158' AZIM:248' 6-7" r h `f ! t0,. CUSTOMER RESIDENCE: GEORGE PERNA ANDOVER,MA 01845 TH u v 1 Fm-4 TYP--� 5,16„ TEL I E-ie«.�:h 5'[16" t-4'TYP # PROJECT NUMBER: 221R 280PERN g DESIGNER: F 8" D.ALLEN 2.'8.. DRAFTER: DI SHEET LAYOUT REV:Al 311/2016 PAGE PV-3.1 1201240 VAC SINGLE PHASE SERVICE OMETER H: M NATIONAL GRID 12 806105 UTILITY GRID SUPPLY SIDE TAP j-4 �! EXISTING (N)LOCKABLE 100A MAIN BLADE TYPE (N)LOCKABLE SOLAREDGE TECHNOLOGIES:SE t BREAKER FUSED BLADE TYPE (N)SUN RUN 10000A-US(240V) AC DISCONNECT AC DISCONNECT METER 10000 WATT INVERTER PV MODULES EXISTING -3 -3 r 3 r 2 j-1 REC SOLAR:REC275TP 100A (35)MODULES PANEL O s - OPTIMIZERS WIRED IN(1)SERIES FACILITY 60A FUSES 'r OF(18)OPTIMIZERS AND(1)SERIES LOADS JUNCTION BOX OF(17)OPTIMIZERS " SQUARE D SQUARE D 250V METER SOCKET LOAD RATED DC MIN RATED NEMA3R SOLAREDGE POWER OPTIMIZER D222NRB DU222RB 125A CONTINUOUS& DISCONNECT&AFCI P300 3R,60A 3R,60A,2P 240V METER 1201240VAC 120/240VAC 200A,FORM 2S CONDUIT SCHEDULE NOTES TO INSTALLER: 1. 18 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. # CONDUIT CONDUCTOR NEUTRAL GROUND 2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN owm onrun 1 NONE (4)10 AWG PV WRE NONE (1)8 AWG BARE COPPER BREAKER IN MAIN PANEL ENCLOSURE.CONDUCTORS ARE FIELD INSTALLED. 2 3/4"EMT OR EQUIV. (4)10 AWG THHNITHWN-2 NONE (1)8 AWG THHNITHWN-2 3 3t4"EMT OR EQUIV. (2)6 AWG THHNITHWN-2 (1)10 AWG THHNITHWN-2 (1)8 AWG THHNrrHWN-2 SOLAREDGE SYSTEM NOTES: 1. SOLAREDGE INVERTER AND OPTIMIZERS ARE A LISTED SYSTEM. 4 3/4"EMT OR EQUIV. (2)6 AWG THHNITHWN-2 (1)6 AWG THHWTHWN-2 (1)8 AWG THHNITHWN-2 2. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND LICENSE NO,750184 MAINTAINED AT 350V DC(NOMINAL). 3. STRING VOLTAGE IS ELECTRONICALLY LIMITED BY INVERTER TO 500V DC,MAX_ 4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS MODULE CHARACTERISTICS OPTIMIZER CHARACTERISTICS ELECTRONICALLY LIMITED TO 15A MAX(PER STRING). CUSTOMER RESIDENCE: 5. SOLAREDGE DC SAFETY SWITCH DISCONNECTS BOTH POSITIVE AND GEORGE PERNA REC SOLAR:REC275TP 275 W MIN INPUT VOLTAGE 8 VDC NEGATIVE DC CONDUCTORS AS REQUIRED BY NEC690.35(A). 280 FARNUM ST,NORTH OPEN CIRCUIT VOLTAGE 38.8 V MAX INPUT VOLTAGE 1 48 VDC I ANDOVER,MA,01845 MAX POWER VOLTAGE 31.4 V MAX INPUT ISO 10 ADC TEL ``F" 1111.1" SHORT CIRCUIT CURRENT 9.4 A MAX OUTPUT CURRENT 1 15 ADC I PROJECT NUMBER: 221 R-280PERN SYSTEM CHARACTERISTICS-INVERTER 1 DESIGNER: SYSTEM SIZE 9625 W D.ALIEN DRAFTER: SYSTEM OPEN CIRCUIT VOLTAGE 18 V DI SYSTEM OPERATING VOLTAGE 350 V SHEET MAX ALLOWABLE DC VOLTAGE 500V ELECTRICAL SYSTEM OPERATING CURRENT 27.5 A REV:A.1 31112016 SYSTEM SHORT CIRCUIT CURRENT I 30 A PER CODE:NEC 69052 PAGE P V-4.O LABEL LOCATION: PER CODE:NEC690.13.GS&NEC LABEL LOCATION: 690.13G4 (AC)(POI) t PER CODE:N EC6NA 3.8 THISLRATI G PEDBY MULTIPLE RENT SOURCE PER CODE:706.12(0)(2) TOTAL RATING OVER CURRENT _ DEMICEQRIENTOINOMAI All NOT GMERCURRENTDEM1tE SNALL NOT EXCEED @ S 9 - - AMPACITY OF BUSBAR 9 6 - Y PER CODE:NE0690.56(C) LABEL LOCATION: NNOEft ROOFlNG MATERIAL) _ - PER CODE:NEC690.13.G.1 ARMING ➢ - "" - LABEL LOCATION' EM BEL LOCATICN: (DC)(I V) (DC)(INV) LABEL LOCATION THE DC CONDUGTORS OF THIS PER CODE:NEC 690.35(F)TO BE USED PER CODE:NEC690.13 B a ON POWERIXJE INVERTER PHOTOVOLTAIC SYSTEM ARE WHEN INVERTER IS UNGROUNDED PER CODE:NEC 690,15 AND NEC 69013(B) UNGROUNDED AND MAY BE ENERGIZED e > BE LGCATION: \\ \ (,�� PER CODE:NEC690.13.8 LABEL LOCATION: LAOELLoc 1011 TURNOFF PHOTOVOLTAIC PER CODEBNEGI 1027(C) '-° `° `°' '•`t (AC)(POI) AC DISCONNECTPRIORTO PER CODE:NEC690.16.0 WORKING INSIDE PANEL LABEL LOCATION: lABEt LOCATION: ACl s2 (AC)(POII) #-mob PER CODE:NEC690,331 2 $ it PER CODE:NEC690.5d - � WARN�N 240 SHOCK —~ LABEL LOCATION: S ELECTRIC SHOCK HAZARD \�\\ LABEL LOCATION: DO NOT TOUCH TERMINAL9 CAG)(POIJ � \\ (INDNIDUAL BREAKERS} TERMINALS ON BOTH LINE AND PER CODE:NEC 690.17.E Rf1SlT ��E'awl PERCODE:NEC705.12.0.3A LOAD SIDES MAYBE ENERGIZED �J .\...� IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT LABEL LOCATION WHEN SOLAR MODULES ARE -a s• $ --_ DO)(I A LABEL LOCATION, EXPOSED TO SUNLIGHT LICENSE NO.750184 PER CODE NEC690.53 PER CODE: :IFC fi0.11DIFC 605.it.id _ NEC 691115,NEC 690.13(B)&NEC 690,14C \� I LABELLOCATICN' INVERTER OUTPUT CONNECTION (POI) CUSTOMER RESIDENCE: DO NOT RELOCATE THIS PER CODE:NEC 705.12.D2 GEORGEPERNA _ OVERCURRENT DEVICE 280 FARNUM ST,NORTH ANDOVER,MA,01845 ra._ evPs _,-_ 1 - LABEL LOCATION: \\� YVfi N'ILI PROJECT NUMBER LEGEND (AD)PER CODE:69o13.a YYfi �V LABEL 221 R-280PERN (AC):AC Disconnect ELECTRIC SHOCK HAZARD ACHPOB ATIQV: (C):Conduit TERMINALSOON eOTN LANE AND PER CODE:NEC 690.17.E DESIGNER: (CB)Combiner Box LOAD SIDES MAY BE ENERGIZED D.ALLEN (D)Distribution Panel - IN THE OPEN POSITION DRAFTER: (DC):DC Disconnect DI (IC):Interior Run Conduit SHEET (INV):Inverter with integrated DC disconnect SIGNAGE (LC):Load Center (M):Utility Meter REV:AA 31112016 (POI):Point of interconnection PAGE PV-5.0