HomeMy WebLinkAboutWiring Permit - Permits #13171-1 - 11 DANA STREET 3/8/2016 Date . . .... .............
3?:NORT/�AyOOi TOWN OF NORTH ANDOVER
° p PERMIT FOR WIRING
88ACHU8E
_.. AJ
' This certifies that ;: ................ ••••• ••• "" ""'
has permission to perform - Y
wiringin the building of... .......................................................................
North Andover,'Mass.
Fee... ... : Lic.No " � 3�
ELECTRICAL INSPECTOR
Check#
(fommonwealtlt of Wamac4ujem Official Use Only
Permit No.
2epartined olJire Servicej
Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/071 (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/7/16
City or Town of: North Andover To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 11 Dana St.
Owner or Tenant Heather B. Rowe Telephone No. 9788360103
Owner's Address 11 Dana St. North Andover, MA 01845
Is this permit in conjunction with a building permit? Yes No (Check Appropriate Box)
Purpose of Building PV Solar System Utility Authorization No.
Existing Service 200 Amps 120 240voits Overhead F-1 Undgrd R,1 No.of Meters
New Service Amps Volts, Overhead❑ Undgrd [_1 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of a safe and code compliant,
qrid tied PV solar system on and existinq residential roof. 32 panels / 8.160 kW
Completion oj'the,1611owing table inoy be waived by the Inspector of lVires.
No.ot'Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above El In®
W-5.ot Emergency Lighting
grnd. gtd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS jNo.of Zones
of
No.of Switches No.of Gas Burners No. I Detection and
nitiating Device
No.of Ranges No.of Air Cond. Total s No.of Alerting Devic I ex
Tons I
Heat Pump Number Ton No.of Self-Contained
No.of Waste Disposers -
Totals:. I Detection/Alerting Devices.
No.of Dishwashers Space/Area Heating KW Local El Municipal other
Connection ry
No.of Dryers Heating Appliances KW Security Systems:'
No.of Levices or Equivalent
No.of Water KW No. of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No. of Motors Total HP Telecommunications Wiring:No.of Devices or Equivalent
OTHER:
Attach additional detail if desired, or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $22000 (When required by municipal policy.)
Work to Start:4/4/16 Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"covet-age or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE F_-] BOND F-1 OTHER E] (Specify:)
I certify, under the pains andpenalties of-petjutyj that the information on this application is true and complete;
FIRM NAME: Skyline Solar LLC LIC.NO.: 21667A
Licensee: James Leavitt Signature 1C.NO.:12572B
(If applicable, enter "exempt"in the license manber line.) Bus.Tel.No.: 732-354-3111
Address: '124 Turnpike t. Suite 10 West Bridgewater, MA 02379t/ Alt.Tel.No.:
*Per M.G.L. c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below, I hereby waive this requirement. I am the(check one [] owner 1:1 owner's aEent.
Owner/Agent - I
PERMIT FEE: $
Signature Telephone No.
The Commonwealth of Massachusetts
Department of IndustrialAccidents
Office of Investigations
1 Congress Street,Suite 100
Boston,MA 02114 2017
www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name (Business/Organization/Individual): Skyline Sour LLC
Address:124 Turnpike Street Suite 10
City/State/Zip:West Bridgewater, MA 02379 Phone#:732-354-3111
Are you an employer? Check the appropriate box: Type of project(required):
1.0 I am a employer with 60 4. I am a general contractor and I 6. ❑New construction
employees (full and/or part-time).* have hired the sub-contractors
2.0 I am a sot&proprietor or partner- listed on the attached sheet. 7. ❑Remodeling
ship and have no employees These sub-contractors have g. Q Demolition
working for me in any capacity. employees and have workers' Building addition
[No workers' comp. insurance pomp. insurance.t
required.] ■ le are a corporation and its 10.❑Electrical repairs or additions
3.❑ I am a homeowner doing all work ifficers have exercised their 11.❑Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs
insurance required.] t c. 152, §1(4), and we have no pV Solar
employees. [No workers' D Q Other
comp, insurance required.]
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
TContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer tliat is providing workers'compensation insurance for-nay employees. Below is the policy and job site
information.
Insurance CompanyName:A.i.M. Mutual Insurance Company
Policy#or Self-ins. Lic. #:VWC-100-6018336-2015A Expiration Date:9/16/2016
Job site Address: 11 Dana St. North Andover, MA 01845 city/state/zip:
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOIC WORD ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby c1 tify nd r the pains and penalties of perjuf y that the information provided above is true and confect.
Si mature: 4 Date:3/7/16
Phone#: 111
Official use only. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License#
Issuing Authority (circle one):
I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical InspcciQr S.Plumbing inspector
6.Other_
Contact Person: Phone#:
Fold, Then Detach Icy Perforations
--OMMONWEALTH OF MASSACHUSE
... . ... .... ...
== TR
. . ..... - L =....... ...
..... ....
... ........ ..
CC
-1: STE-R- S
fff 3�
• f r!ff%jl j%fjrrJf ED M'A C
.... ......
.... .. .. .
.. .. ........
....... ....
i1
ftff r
7 f If tt r t t f f tr tr t ,rF t
NE S GLA
. ... ... .... P4�:'
r Mf rl •;>r rt
f '
,�.r•, ,.r, 1 ..
f f,...y
rt
t f
i
fN
t ,1<
�f t
t i7; r
f r f
' l• f. f......
.. . ........ ..........
i
-.... ... .....
..... .....
YN/ f
'
,l �s
i r
t.
4
f
,�
I 'I
. ... .... ....
f !;
VV
r .rf . zt ltf iME*S
t'I ' '� .
r jt�- f z
✓u124 TURTiw't"K-E .
.... . ... ...
c,f/
!4
...... ...
.... ....... MA
- 2 .
(C� 7 5 '.' _
.... .... .... ......
..... ... ... ......
.. ... ... .....
-71
216 G"
34^503 U
Q
U
t�
U
Co
1 3 4 5
PHOTOVOLTAIC SYSTEM SHEET INDEX
PV0.0 COVER AND SITE PLAN
PV1.0 GENERAL NOTES
SYSTEM SIZE: PV2.0 ARRAY LAYOUT
AC/DC kW STC: 7.238kW 18.16kW ' PV3.0 LINE DIAGRAM
PV4.0 LABELS
EQUIPMENT:
A
PV MODULES: (32)Trina SolarTSM-255 PD05.05
KEY:
INVERTER(S): (1)SolarEdge SE760OA-US --—PROPERTY E CONDO RUN Q INVERTER
DRIVEWAY SUBPANEL
SCOPE OF WORK: FENCE E)DC DISCONNECT
FIRE CLEARANCE AC DISCONNECT
INSTALLATION OF A SAFE AND CODE�COMPLIANT ROOF 1. STRUCTURAL
G CTURAL `-i�JUNCTION BOX
GRID-TIED SOLAR PV SYSTEM ON AN EXISTING ARRAY 1
RESIDENTIAL ROOF TOP. .—� SOLAR MODULE MONITORING UNIT
I Q MAIN SERVICE PANEL ❑�`. COMBINER BOX
UTILITY METER ROOF
ROOF 3 ,1 Q PV METER OBSTRUCTION
ROOF 2 ARRAY 3 APPLICABLE CODES:
ARRAY 2 2014 NEC
2009 INTERNATIONAL CODES WITH MA
ROOF MOUNTED AMENDMENTS
CONDUIT
i
1
CONTRACTOR INFORMATION: B
UNITED SOLAR ASSOCIATIES MALDEN
z ` \ 452 PLEASANT ST.
MALDEN,MA 02148
p
i III JURISDICTIONAL INFORMATION:
NORTH ANDOVER,TOWN OF
1600 OSGOOD ST.
NORTH ANDOVER,MA 01845
\I NOTES TO INSTALLER:
1 LOCATION OF MAIN
SERVICE PANEL `
INSIDE BASEMENT Ott
FOR INSTALLER USE ONLY
POST INSTALL SUNEYES REQUIRED? NO
I CERTIFY THAT NO CHANGES HAVIE C
pAp1PSS ` \, BEEN MADE TO THE ARRAY LAY04T:
CUSTOMER INFORMATION:
\+ \ HEATHER B ROWE
1 NORTH ANDOVER,MA 01845
SITE PLAN N (978)836-0103/#21541.02
SCALE: N.T.S.
DESIGNED BY: REV#: DATE:
PV-0.0
VALID.B 1 0 1 Z/23/16
BUNOEVf1Y IN4SB FRANKNNS-f SURE�t00AgANO.CA0460] By.AUW Dab:—tornibn:Rowo-2154102 Nl Shoat51u:11a'1] 1 ESEORAWINGS,SPECIRCA¶ONS.AND OESIONSARET EPROPIB—OFSUNGE—WG NO PART SHALL BE COPIED OR U.s FORORWIT ANYOT WORKOiHFATi4 ESPEFIFICPROJE FORWHICRT VH ESME DEVELUPEOWR DO OURWRiIiENCONSENi
1 2 3 4 5
GENERAL NOTES. ELECTRICAL NOTES:
GENERAL NOTES: E1.ALL EQUIPMENT IS.LISTED FOR USE.
N1.DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF E2.MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC.
RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE E3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE
NOTED OR STANDARDIZED. NEW AND LISTED BYA,RECOGNIZED ELECTRICAL TESTING LABORATORY.
N2.ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. E4.AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY
N3.IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT,WIRE,EQUIPMENT DE-ENERGIZE ITS OUTPUT-TO THE CONNECTED ELECTRICAL PRODUCTION AND A
DEVICES,OVERCURRENT PROTECTION,GROUNDING SYSTEMS,ETC.(ALL DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN
EQUIPMENT AND MATERIALS)THE CONTRACTOR SHALL BE RESPONSIBLE.FOR IN THAT STATE UNTILTHE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK
PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE VOLTAGE HAS BEEN RESTORED.
STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ES.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION.
ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE E6.ANY ACCOMPONENTSHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT
LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. CALCULATED AT THAT COMPONENT.
N4.ALL OUTDOOR EQUIPMENT SHALL,BE MIN.NEMA 311 RATED. E7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE
N5.METAL CONDUITAND ENCLOSURE S SHALL BE USED WHERE PV SOURCE OR PROPERLY GROUNDED.
OUTPUT CIRCUITS ARE RUN INSIDE BUII.IDING. E8.DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM.
N6.MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST E9.MARKINGS SHALL BE I ROVIDED TO INDICATE THAT ALL CONTACTS OF THE
6"ABOVE FLUSH VENTS. DISCONNECT EQUIPMENT MIGHT BE ENERGIZED.
N7.THE ELECTRICAL CONTRACTOR SH,ALLCOMPLY WITH ANYANDALL E10.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES
REQUIREMENTS GIVEN BY UTILITY COMPANIES. OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL
Ng.FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEETS. REQUIREMENTS.
N9.ALL LABELS AND MARKINGS SHALL BE,ATTACHED ACCORDING TO Ell.FOR ANY UNGROUNDED PV SYSTEM,A LABEL READING:
REQUIREMENTS BY NEC AND THE LOCALAHJ.THE AHJ MAY HAVE SPECIAL LABEL B
REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT.THIS MAY ENCOMPASS "WARNING-ELECTRICAL SHOCK HAZARD.THE DC CONDUCTORS OF THIS PHOTOVOLTAIC
LANGUAGE INCLUDING,BUT NOT LIMITED TO,THAT FOUND IN NEC ARTICLES SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED."
699.5(C),690.14(C)(2),690.17,690.53,680.35(F), 690.54,690.64(B)(7)and SHALL BE PLACED AT EACH JUNCTION BOX,COMBINER BOX,_DISCONNECTAND DEVICE
70S.10 WHERE ENERGIZED,UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE.
N10.INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. E12.INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION
N11.ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC DEVICE.
REFERENCES. E13.ALL METALLIC RACEWAYS AND EQUIPMENTSHALL BE BONDED AND ELECTRICALLY
N12.IT IS ILLEGAL FOR ANYONE UNLESS ACTING UNDER THE DIRECTION OF A CONTINUOUS.
LICENSED PROFFESIONAL ENGINEER OR REGISTERED ARCHITECTTO ALTER ANY E14.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC.
ITEMS ON THIS PLAN.
ESS.BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED Air THE OPPOSITE END OF THE
N13.THE ENGINEER HAS NOT BEEN RETAINED FOR JOB SUPERVISION. CIRCUIT OR FURTHESTAWAY FROM THE MAIN BREAKER.
E16.ALL WIRE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO
STRUCTURAL NOTES: TEMPERATURE DERATING AND LOCATION.
Sl.MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE,BUT E17.ONLY COPPER(CU)CONDUCTORS SHALL BE USED.CONDUCTORS SHALL BE
SHALL BE ACCURATELY SPACED. STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS.
C
52.MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE E18.DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED
LOAD AMONGST RAFTERS. E19.ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED CUSTOMER INFORMATION:
S3.DO'NOT SPLICE RAILS IN MIDDLE 50%OF SPAN BETWEEN TWO MOUNTS. GROUNDING(PLEASE SEEIDATA SHEET)OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN HEATHER B ROWE
LUGS USING STAINLESS STEEL HARDWARE,STAR WASHERS,AND THREAD FORMING 11 DANA STREET
BOLTS. NORTH ANDOVER,MA 01845
E20.ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE (978)836-01031#21541P2
NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL.
DESIGNED BY: REV#: DATE:
PV-1.0
VALID.B 1 0 1 212311E
..UNGEVRYINC6C FRANNt1NSTGUITEBiBOP1GANp.DABI60T By.MIOY DoIa:-loolbn:Rvuv21561D2SVt SM1ootSltv:llsiT THESE DRAWINGS,SPECIFICATIONS AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC.NO PARTSH BE COPIEDOR USED FOR OR WITHANY OTHER WORKOTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HIVE BEEN DEVEL6PED WITiDtROURWRti1HN CONSENT
1 2 3 4 5
MODULE SPECIFICATIONS '
(32)Trina Solar TSM-255 PD05.05
MODULE WEIGHT: 41
MODULE LENGTH: 4.
MODULE WIDTH: 39.05
34'-2" CONTINUE TO ARRAY 3 ROOF 1 SPECS
RAFTER SIZE: 2X8 NOMINAL
RAFTER SPAN:
RAFT ERSPACING: 16"
ROOF MATERIAL: COMPOSITE SHINGLE
ARRAY I SPECS_
NU
I I
BER OF MODULES: 20
1 I I I I 1 ( I I 1 RQOF12 I 1 ( I I I 1 I I TOTAL MOD.WEIGHT(Ibs): 820 A
1 I I I I 1 I I I ARRp Y 2 1--1- �- I RACKING WEIGHT(Its): 153.2
I I I I I ARRAY WEIGHT Ibs). 973
_ _i _ I _ �._ I __ i_ i I --( ® �-• I I I I 1 I I I I I ARRAY AREA(sqk): .3
co I _1 __ _J �_ I I ARRAY DEAD LOAD(Ibs/sgft): 2.8
r!l
I 1 I I I IROpF 1h I I I_ I ( I® __ :- °D I I I ( I I I NUMBER OF MOUNTS: 43
PR'Rr'a I I I ( I I 1 ' _ I--I I 1 LOAD PER MOUNT(ibs): 22.6
- --�.--- I ARRAYAZIMUTH(") 165
( I I I I I I I I I I ( 1 I 1 1 ARRAY TILT(`) 35
_ _
____ _ I NUMBER OF FLOORS 1
ROOF25PECS
I I ( ( ( I I I I I I 1 I I I ( RAFTER SIZE: 2X8 NOMINAL
t _� � __.�_.®—� RAFTER SPAN: 8'-4"
1 I I i 1 I I I I I i _ RAFTER
ROOF COMPOSITE SHINGLE
ARRAY 2 SPECS
6" NUMBER OF MODULES: 6
TOTAL MOD.WEIGHT rRRAY 2 LAYOUT RACKI G WEGHT(Ibs):ts) 56
246 2 SCALE-3/16"=T-0° ARRAY WEIGHT(Ibs): 302
ARRAY AREA(sqft): 105.7
-4 \LARRAY 1 LAYOUT ARRAY DEAD LOAD(Ibslsgft):NUMBER OF MOUNTS: 17 17
SCALE:3116"=V-0" LOAD PER MOUNT(Ibs): 17.8
ARRAYAZIMUTH(") 255
ARRAY TILT(') 24 B
NUMBER OF FLOORS 1
ROOF SPECS
RAFTERSIZE: 2X8 NOMINAL
RAFTERSPAN: 8'-4"
RAFTER SPACING: 16"
ROOF MATERIAL: COMPOSITE SHINGLE
ARRAY SPECS
NUMBER OF MODULES: 6
TOTAL MOD.WEIGHT(Ibs): 246
4'-1 1" 13'-1" WEIGHTRACKING 56
ARRAY WE G T(lbs ).)S 302
I I I SOLAR MODULE
ARRAY AREA(sgft): 105.7
I ROOF � I I ( I I I ARRAY DEAD LOAD(Ibslsgk): 2.9
ARf2AY 3 "T' ( NUMBER OF MOUNTS: 17
1 I I I I ( 1 ARRAY AZIMOUniN(,ibs): 18
75
SYMBOL KEY: I _� __ ( _� C__ I IRO'NRIDGEXR100 �..✓ ARRAY TILT(') 24
------- RAIL ( I 1 1 ( I 1 I I I L-FOOT NUMBER OF FLOORS 1
——--— RAFTERS ----I - - -- ( QMSE-LAG SHINGLE
I i l
---- RooF I I COMPOSITE SHINGLE
FIRE CLEARANCE - I 5"X 5/16"-LAG
O.•-•••-•O STRING CONFIG. 2.5"MIN.EMBEDMENT PER C
STRUCTURAL SCREW CUSTOMER INFORMATION:
UPGRADES 2X8 NOMINAL,16 O.C.
Q SOLAR MODULE HEATHER B ROWE
AMOUNTING DETAIL 11 DANRTH ASTRE ER,MA01845
® MOUNT A 11 DANA STREET
RAY 3 LAYOUT `F SCALE: NTS
® SKYLIGHT (978)836-0103/#21541,02
® CHIMNEY SCALE: 3/16"=1'-0"
PLUMBING OR
° ATTIC VENT - DESIGNED BY: REV#: DATE-
0 ATTIC VET
VALID.B 1 0 1 2l23116
BUNGEVIfYiNG.6fi FPNNI(LINSTSURE]18 DAKIANO,GBIEO] By.AUDY DoIo�Lomibty Rmn-2USa1025V23h"atsita ttzt] THESE DRAWINGS,SPECIFICATION&AND DESIGNSARETHE PROPERWOFSUNGEVITY ING NO PARTSNA BE COPIED ORUCED FOR OR MTHANYOTHERWORK OTHERTHAN THESPECIPC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHONTOURMR`PCN CONSENT
1 2 3 4 5
ELECTRICAL KEY: MODULE ELECTRICAL SPECIFICATIONS INVERTER 1 SPECIFICATIONS
BREAKER (32)Trina Solar TSM-255 PD05.05 SOLAREDGE SE760OA-US
-�— SWITCH SHORT CIRCUIT CURRENT(Isc): 8,88 RATED WATTS(EACH): 7600
OPEN CIRCUIT VOLTAGE(Voc): 38.1 AC OPERATING VOLTAGE IV): 2qp
SCREW TERMINAL OPERATING CURRENT(IMP): 8.37 AC OPERATING CURRENT(A): 32
e9 FUSE OPERATING VOLTAGE(VMP): 30.5 NUMBER OF MPPT CHANNELS 0
A SPLICE MAX SERIES FUSE RATING: 15 INVERTER EFFICIENCY: 0.975
EARTH GROUND STC RATING: 255 INTEGRATED OC DISCONNECT
m CHASSIS GROUND RTC RATING: 239 INVERTER 1 INPUT SPECIFICATIONS
——— GEC DESIGN CONDITIONS NOMINAL CURRENT PER STRING(loom): 11.7.11.7
EGC HIG G.CR OB DESIGN TEMP('C): 32 NOMINAL VOLTAGE Nnom): 350
MIN.MEAN EXTREME ANNUAL DB(°C): -18 MAX SYSTEM VOLTAGE(Vmaz): Soo
MAX CURRENT PER STRING(]max): 15 A
MAX INPUT CIRCUIT CURRENT(Imaz): 30
200A MAIN BREAKER
(3)#8 THWN-2 (3)#8 THWN-2 (3)#8 THWN-2
(4)#10 PV-Wire (4)#10 THWN-2 (1)#8 GEC (1)#8 GEC (1)#8 GEC
(1)#10 EGC_ (1)#10 EGC 3/4"EMT 3/4"EMT 3/4"EMT
FREEAIR 3/4"EMT
METER
AC DISCONNECT, (E)LOADS
(N ERTE 014-US r�-
INVERTER VV/INTEGRATED 60AMP,
DC DISCONNECTS NON-FUSIBLE,C.H (E)LOADS
DG222UR6 (E)200AGEMSP
1 STRING OF + MPPT 1 40A 2P� 240V 2P 3-W 10?
LOCUS
16 MODULES �— —AC METER
3 OPT.CURRENT=11.66A DC« :OUTPUT LOAD LINE
_____ -------- ��--- --= — —�— — — -- ..
........
—' -------- B
1 STRING OF + MPPT2
16 MODULS
OPT.CUR ENT=11.6fA 4 INVERTER
GEC IRREVERSIBLY SPLICED TO
EXISTING GEC OR BONDED DIRECTLY
TO EXISTING GROUNDING ELECTRODE
(IF APPLICABLE)
MIN.NEMA3R UL LISTED JUNCTION
BOX WITH 90°C TERMINAL RATINGS
LOCATED ON ROOF
C
Inom=(16 x 255W)/350V=11.7A CONDUIT ELEVATION:1/2 TO 3-1/2"=22"C 32 MODULES TOTAL
OPERATING VOLTAGE=35OVDC(REGULATED) HIGH AMBIENT TEMPERATURE:32°C 32 x 232(PTC WATTS)x 0.975=7238 CEC WATTS CUSTOMER INFORMATION:
EXTREME LOW:-18"C HEATHER B ROWE
200 x 1.2=240 ROOFTOP,AMBIENT TEMP(Tcorr):54"C=0.-76 SE760OA-US MAX OUTPUT CURRENT=32A
240-200(MCB)=40A CONDUIT FILL(Cfill):0.8 BREAKER SIZE=$2Ax 1.25=40A=>40A 11 DANA STREET
MAX ALLOWABLE AC PV BREAKER=40A NORTH ANDOVER,MA 01845
CONTINUOUS USE=imax*1,25=15A (978)836-0103/#21541:02
CONDITIONS OF USE=Imax/Tcorr/C1"ll
15A/0.76/0.8=24.67A
CONDUCTOR SIZE FOR 24.67A DESIGNED BY: REV# DATE:
INSTALLATION SHALL USE MIN.#10 AWG PV-3.0
VALID.B 1 0 1 2/23/16
aNxaMIttlN4aeFMNKUN 3T5YITElt00PKtAND.GW001 ey:AUOY Deb�laaibRRvu"-315s102aYe SMMSixa:ttst] THESE aR0.Wix0.5.SPECIRCATONa.AND DESIGNS ARERHEPROPERT'OFSVNOEVnYiN4 NO PARTStuLL aE DDFIS�Da U:ED FORDRWm1ANYDINFR WORK OTHER THnN THE aPE<IFlC PR¢1ECTFOR WHICH TNEY NAVEREEN DEVELDFEa WiTHDNT DUR WRITIF>J CONSFM
1 2 3 4 5
NEC 690.5(c) NEC 690.31(E)3&4;2012 IFC 605.11.1 INTERACTIVE PHOTOVOLTAIC POWER SOURCE
PLACE THIS LABEL ON INVERTER(S)OR NEAR PLACE ON ALL JUNCTION BOXES,EXPOSED _
GROUND-FAULT INDICATOR(ON[INVERTER(S)U.O.N.) RACEWAYS EVERY 10'ANQ T FROM BENDS RATED AC OUTPUT CURRENT(A): 32
AND PENETRATIONS,ADJACENT TO THE NOMINAL OPERATING AC VOLTAGE IV): 240
MAIN SERVICE DISCONNECT
WARNING WARNING INVERTER 1 DC DISCONNECT
PHOTOVOLTAIC SYSTEM DISCONNECT
a ELECTRIC SHOCK_HAZARD RATED MAX POWER POINT CURRENT(Imp): 23.3
IF A GROUND FAULT IS INDICATED, RATED MAX POWER POINT VOLTAGE:(Vmp): 350 A
NORMALLY GROUNDED CONDUCTORS PHOTOVOLTAIC POWER
MAY BE UNGROUNDED AND ENERGIZED
SOURCE MAX SYSTEM VOLTAGE(Voc): 500
SHORT CIRCUIT CURRENT(Isc): 11.1
NEC 690.17(E) NEC 690.35(F)
PLACE THIS LABEL ON ALL DISCONNECTING PLACE THIS LABEL AT EACH JUNCTION BOX,COMBINER BOX,
MEANS WHERE ENERGIZED IN AN OPEN POSITION DISCONNECT AND DEVICE WHERE ENERGIZED,UNGROUNDEDL
CIRCUITS MAY BE EXPOSED DURING SERVICE:
WARNING WARNING
ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND LOAD THE DC CONDUCTORS OF THIS
SIDE MAY BE ENERGIZEDrIN THE OPEN PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
POSITION AND MAY BE ENERGIZED
NEC 705.12(D)(2)(b)
B PLACE THIS LABEL AT P.O.C.TO SERVICE B
DISTRIBUTION EQUIPMENT(LE.MAIN PANEL AND
SUBPANEL IF APPLICABLE))
NEC 690.56(c)
WARNING
/� �j h''I(�'I� PLACE ON RAPID SHUT DOWN DISCONNECT WHEN RAPID SHUT
��//- R v (V DOWN IS INSTALLED
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS PHOTOVOLTAIC SYSTEM EQUIPPED
OVERCURRENT DEVICE WITH RAPID SHUTDOWN
NEC 705.12(D)(3)
PLACE LABEL ON ALL EQUIPMENT CONTAINING
OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER
TO A BWSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE
SOURCES.
CA U IRC I®N NOTE
OUTSIDE LABELING OF SYSTEM COMPONENTS AND METERS
IS TO BE DONE IN A WAY SUITABLE FOR THE ENVIRONMENT C
CONTAINS MULTIPLE POWER IN WHICH THE EQUIPMENT IS INSTALLED.NO STICKERS ARE
SOURCES PERMITTED. CUSTOMER INFORMATION:
HEATHER B ROWE
NOTE:
11 DANA STREET
BACKGROUND AND ILETTERING COLORS FOR NORTH AN MA 01845
SIGNAGE/LABELS SHALL COMPLY WITH(IN ORDER OF (978)836-010303 1#21541;02
PRIORITY)AHJ&FIRE DEPARTMENT AMENDMENTS,
STATE CODE,AND ANSI GUIDELINES.THIS PAGE IS DESIGNED BY: REV#: DA7E:
INTENDED FOR SIGIVAGE/LABEL VERBIAGE ONLY. PV-4.0
VALID.B 0 2/23/16
BOxofiv(ry IUGGB FRANN4x+TGOITE]fO DAgANO.GweBT By.MroY Om..�tc®Ban.Rnwa.3MsfB2SVISIwot�Irn:ffxfT THESEOMWINOS,CFEOIFlGTIONS,AND OESIONSMGTHE PROPERTY OFLONGEVITY WC.NOPARTSHALLBECOPIEDOROSEOFORORWR AN TOT WORDOTHERTHANTHESPECIFlO PROJECT FOR WHIGITHEY HAVEBEEN DEVELOPED WITHOIfFOUR WRITTEN CONSENT
Mono UIII SolutionsINN
°
,CO CTS f717 I G ELECTFICA DATA.57C)
7 I� TSM PD05 250265W Peak Powar Wotu-Peu.iWP) .5 250 255 260 265
j 4u_ tomy'" (C TSM-PDO5.08 2507265W Moamar Output Toloranco-Pw.121 0-+3
dilt, 3 bi iSM-PDO5.05 2+5-260W 'mum PowvrVOitago-VunM 29.9 ]0.7 30.5 J0.6 30.8
C ° Ma%1mvm POwor CVrtanl-lurr(A) 8.20 8.27 8.3J Sze e.dl
011.1EW ICw Oft`:-i+lODU�( Open omtil Vaitage-Vpc(V) 37.8 38.0 38.1 382 38.3
3 ' m
��39yy9gqtt t�,lq ` �l Short Circuit Curtonl-hc(A) 8.75 8.79 8.88 9.00 9.10
941 Module Er4cl...y,(S.) 15.0 15.J 15.6 15.1 16.2
lis
4T� io STCirtadlonce tBBD W/-rt'.Cell Tomppralura 25•C.AIt MovxAM15.
iyple01 a1BeleneyratleClio 14,k012t1p W/maecordirp to EN 609pb1.
FIECTPiCA 0
i
P�uriWPi 382 186 19D 193 197
0
� 4 ti - J° t meemum Power Vottoo V (ul 27.6 28.0 28.1 28.3 28.4
affi Y ',, PDO$.0$ M=IMUM POWaf C-1-1u1°(At 6.59 6.65 6.74 6.84 6.93
MULT€CRYSTALLLINE MODULE Open co-cpavmmga-vadIV) 35.1 ass ua 35.4 ass
Short Grcuil Current-Ise(A) 107 110 117 1.21 135
i to e - ,3 P005.08 t,t-Irrodlonce It eoo w/m°.Amc omrempprpmroaB•c.Wmd So-l ma.
6��
245-265 D PD0,5
POWER OUTPUT RANGE product �aa A- -Aso)oreero Muwcnlomnes6•ls6mmiainenc.)
� Ou rrt ;e
L�63 C tr i0 305C n.�nr..r _ /� Call orlanlallon 60caits(6r 10)
9 Madvla dunoiulans 1650°992.75 mm(64.95%39.05z127 lnchas)
c LLc;6 as 10o
wal9nl les kg(anbj
__ -_ _ eackvow Girt. 3.2mm(0.13 inchas).Hlgh TrallsmisslPn.AR Coaled Tempered Glass
tv1C-IYiEC4`�UiVtEI�FiCEsNCY Back:naar while(P0058PD05.06);Black(PD05.05)
Peamo S111e1 Anodized Aluminium Art,iPD05):81aek(Po05A88PD05.05)
.1•Box IP 65 of IP 67 rated
@- $ t ice: 7/ t - _ :UIICr, Cobies PhotovoilalcTechnalogY cable 4.0mm'(0.D061nches').
r �yf s
a6 ''��4 � � t000mm139.]71nches)
POSITIVE POWER TOLERANCr- - --- - l 16 I Al Connaetor MCACampolibie
Hlg ly re to string a uc-i i
0 v :t,VTC, 1 1n r -v cuavcto=Pv scaDL r:.ct
TEMPERATUtE I.AtIU ai !1 #IMU' .GS '���'c
.-I-1 Operating Coll
TOmpolalu OparOl1on0l iomparaNre •40-°8$°C
C 1 ro INOCTi. 44'C i=2'q
MO%1mum swtom 1000V DCIIEC)
Tomperolure Coeftenl of P. -0.41P./°C Volloga 1000VOC IUQ
C D F 11 - �- s M - \,\1- Tcmparalura CoelBclent al Vac -0. %PC 15A
Maz Scrles PVSe Roling
p U = I li Ivry i�� Tomporptum coa(nclonl of lsc 0.0=-C
^�. er ifs .�.hs9ared eilcicerg.ng
•�- Apt c trG 11�
Cr.1ii cl �----
• - a to ..,�,s° a a lOYearProdvcl workmarlsltlP Warranty
__r ICIOIC IGh �-.IF � 25 Ycor Unoar PowenWottanty ,
II l-rr.lrt 1..I ame.....peodudwaw6ry lortleloaq
., �,.... PACKAGM--CO.'McATIO^(LINEAR 3E p ppiV } i ] Nq CE ry
� e
'ea('t0 2S Yeor Ll ar:`Dwvr- Jr�iv Lin-� �� MOd:,D:perbo%:30places
Modules Per 4D'contalnar:840 pieces
x x
2 g - �- r/ - CAIITIONNUDSAfE1YANDINSTAUATONIN51flUCTIONS BEFOflEU51NGTIEPR000GI
weiA'Iiry kitN'r.+11f`4J�.+, a2015i4nvSaiefUmllptl.Ailrignlrroiprvod.SDpcl6c011omincludedlnlhl[dol0[haolamspb7ocltochoneowlitbutnolkp.
J if !?3��7� jQOC
e q/roacuy- Yoans 10 11 ,e .rlenr�yrpq.m,1
CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE
Certificate Number 20140630-E306515 Certificate Number 20140630-E306515
Report Reference E30651 5-2012121 3 Report Reference E306515-20121213
Issue Date 2014-JUNE-30 Issue Date 2014-JUNE-30
Issued to: TRINA SOLAR LTD The modules with the specified construction as below may be marked with its type
for UL listed fire performance products only as the below table:
2 TIAN HE RD,ELECTRONICS PARK NEW DISTRICT,
CHANGZHOU,J14NGSU 213031 CHINA, Module model Specific construction Marking
TSM-xxxPD05, Superstrate: 3.2-4.36mm thick; Module Fire
This is to certify that PHOTOVOLTAIC MODULES AND PANELS WITH TSM-xxxPD05.08 EVA: 0.25-0.61mm thick; Performance:
M Substrate: 0.30 mm - 0.64 mm Type 1
representative samples of SYSTEM VOLTAGE RATINGS OVER 600 VOLTS thick;
Refer to addendum page for Models Frame:
Cross sectional dimension: 35
x 35mm,
Height: 35mm,
Have been investigated by UL in accordance with the Thickness: 1.5mm
Standard(s)Indicated on this Certificate. TSM-xxxPD05 Superstrate: 3.2-4.36mm thick; Module Fire
TSM.-xxxPD05.05, EVA: 0.25-0.61mm thick; Per£ormance: l
Standard(s)for Safety: UL 1703-Standard for Safety for Plat-Plate Photovoltaic TSM-xxxPD05.08 Substrate: 0.284 mm - 0.30 mm Type 2
thick;
Modules and Panels and ULC ORDIC1703-01-Flat-Plate Frame:
Photovoltaic Modules and Panels. Cross sectional dimension: 35
Additional Information: See the UL:Online Certifications Directory at x 35mm,
Height: 3 Smm,
wvvvd.ul.cem/database for additional information Thickness: 1.5mm
TSM-xxxPD14, Superstrate: 3.2-4.36mm thick; Module Fire
TSM-xxxPD14.08 EVA: 0.25-0.65mm thick; Performance:
Only those products bearing the UL Listing Mark for the US a d Canada should be considered as
it Substrate: 0.254 mm - 0.S00 mm Type 8
being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US thick;
and Canada. Frame:
The UL Listing Mark forte and generally includes: e n a circle symbol.with C
h US Cad n ll ild the UL i " " Cross sectional dimension:
and"US"identifiers:'&rthe word"LISTED";a control number(may be alphanumeric)assigned 40-35 mm,
by UL;and the product category name(product identifier)as Vindicated in the appropriate UL Height: 40mm,
Directory. Thickness: 1.5 mm
Look for the UL Listing Mark on the product TSM-XXXPD05.10 Superstrate: 3.2-4.36mm thick; Module Fire
TSM-XXXPD05.18 EVA: 0.25-0.65 mm thick; ' Performance:
Substrate: 0.025 - 0.284 mm Type 5
thick;
Frame:
Cross sectional dimension: 40*
38 mm,
Height: 4 0mm,
p a��i,we,/ Thickness: 1.8mm
e-7
ry,cintivr,N"M Amerlwn ceNheden PnOmmv
ULLLC wn1LLCRC"mry,clne[gq NVM Mwdun GNgwaon Propnmv ,
I
MY Momupvn vna tlgwmwnmtlgn lnvolvmpuLNvrloon on pnvNvaen tiaM1Nrof ULLtc�Uygrany napwmavefULForquavdoM1v,plevev q Mn mbmwtivn Pnativwmanmdon�nvvlvinguLNvrkvervlcv rovitivd an bebalror ULuc�Uy grvny vupwdndllcemva"f ULFvrqundoim,plvuv
wnN¢plxal UL eprmmvr5erviru RepncvnYNM qt_rvwl co Ntl•IomI VL Luammet Svrvlga RepnegnNllw qt+_.�, ��
Page 1 of 4
Page 3 of 4
solar=@@
S0 a r' m Single Phase Inverters for North America
SE3000A-US/SE330OA-US/SE5000A-US/SE6000A-US/
SE7600A-US/SE10000A-US/SE11400A-US
SE3000A-US 5�3IlOOA-US SCSOOOA-US SE6000A-US SE7600A-US DNA-us 5E31400A US
OUTPyT-.
SolarEdge Single Phase Inverters l - 00 998IOD0@20av - A
Nominal AC Power Output 3000 3800 5000 6000 7600 9980@208V 11400 VA
Q •(+. Max.At Power Output 3300 4150 5400 @ 208V 6000 93SO 10800 @ 208V 12000
For North America 5450@240V 10950@240V VA
AC Out put Voltage Min.-Nom:Maz.l° _ '.
183-2;-229 Vac -
SEJqOOA-US/SE380OA-US/SE�000A-US/SE600DA-US/ ACCengeVokaCeMln:Nom:Max.1"
SE7�,OOA-US/SE10000A-US/SE1140OA-US AC Frequency Mae
AC Frequency Min:Nom:Max!v 59.3-60-6D.5(with HI country setting 57.60-60.5) Hz
Max.Continuous Output Current 12.5 i 16 24 @ 2D8V 25 32 48 @ 208V 47.5 A
21 @ 240V 42 @ 240V
GFDIThreshold 1 A
-Utility M tbring,l landing Protection,Country Configurable Thresholds Yes Yes
4` INPUT
`overt°. Ma mum OC Power(SfC1 4050 5100 6750 8100 }0250 13500 35350 'W
2CJ r n;fo mer-less,Ungrounded Yes
nn rs Max.Input Voltage Soo _ Vdc
Wyttaltti^ Nom.DC Input Voltage 325 @208V/350 @ 24pV Vdc
t.°nAA Max.Input Currant'u 9.5 13 16.5 @ 208V 18 23 33 @ 208V 34.5 Adc
15.5 @ 240V i 30.5 @ 240V
Max,Input Short Circuit Current 45 4,dc
y Reverse-Polarlty Protection Yes
Ground-Fault isolation Detection 600k.Sensitivity
Maximum Inverter Efficiency 97.7 98,2 98.3 1 98.3 98 98 98 %
CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V 97.5
9.@ 240V 97.5 @ 240V
Nighttime Pwmr[onsumpdon <2.5 <4 W
ADDIT1ONALFEATURES __
Supported Co nication Interfaces _-- - R5485,R5232 Ethernet,L 6 �.ptiona1)
Revenue Grade Data,ANSI C12.1 Optional a
,p A Rapid Shutdown-NEC 2024690.12 Funcrionality enabled when SolarEdge rapid shutdown kit snstalled'"
STANDARD COMPLIANCE
.� Safety UL1741,U116998,UL3998,CSA 22.2
'1 Grid Connection Standards IEEE1547
n Emissions FCC part15 155 8
INSTAL�.ATION SPECIFICATIONS __ __ _ _
AC utoutconduit size/AWG range 3/4"minimum/16-6 AWG 3/4-minimum/8-3 AWG
O vC' cconduit size/#of strings/ 314"minimum/1-2 strings/
-. 3/4"minimum/1-2 strings 116-6 AWG
AWG range 14-6 AWG
Dlmens�ons with Safety Switch 315 x 184 30.5x12.5x 10.51 in/
30.5 x 12.5 x 7.2/775 x
(HxWxd} 775 x315x 260 Pre
Weight with Safety Switch 51.2123,2 54.7/24.7 88.4/40.1 ib/kg
a Natural
' cbnvcttfon
Cabling Natural Convection anr�internal Fans(user replaceable)
' fan(user The�est choice for SolarEdge enabled systems m la<eable)
Noise <25 <50 qBA
Integra ted arc fault protection(Type l)for EC 2011690.11 compliance Min.-Max.operating Temperature I„
- Superior efficiency IBM) Range -13 to+140/-25 to+60(10 to+60 vol;ion awilablc ) 'F./'C
Protection Rating NEMA3R _
- Small,lightweight and easy to install on provided bracket i°r°romp.�ecmnm pp[Ypac plppsp raptpesomteac=•°pppR
��A hi6hercvrtent sourte may be usetl;the lnvenprwlli llmltlC lnpu[wrtenr tp Uievalues staled.
- Built-in module-level monitoring �Pwp°po cmap opener Pam soagw-us°o°NNPximnsapw lmpnofsE]tlooA-uSoa:NNP:I.
I�'Papid shitdP/N Wt PJN:SEtpeaNNUalf
Internet connection through Ethernet or V%{ireless °'-0v vcrLpn P/N:SrraW-USppONNU6({or]6vOW I1venerSE7GovA-USW3NNU4).
Outdoor and indoor installation
Fixed Voltage inverter,DC/AC conversion only -
Pre-assembled Safety Switch for faster installation
Optjona l-revenue grade data,ANSI C12.1 m
USu.UEERNv4N"-ITALy FRADICE-1AJP C Ill,IA-AUSTRALIA-THE NETHCRLAPD4-ISRA@L _
-uJlsJ4V,SG�d i'E.a�C-.US
AUTHORIZATION TO MARK AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s)shown below to the models described in the Product(s) Product: Utility Interactive Inverter
h Brand Name: SolarEdge
Covered section when made in'accordance with the conditions set forth in the Certification Agreement and Listing 7 models:$E3000,SE3300,SE3800,5E5000,SE6000;SE7000,SE7600
Report.This authorization also applies to multiple listee models)'identified on the correlatioh page of the Listing Models:
Report. (Option:followed by,A to indicate Interface board,etc.)
This document is the property of intertek Testing Services and is not transferable.The certification mark(s)may be
applied only at the location of the Party Authorized To Apply Mark.
Applicant: SolarEdge•Techno'ogies Ltd Manufacturer: Jabil Circuit(Guangzhou)LTD
DEV EAST DISTRICT
6 Ha'Harash Street45240 128 JUN CHENG RD
Address: Hod Hasharon Address: GUANGZHOU
GUANGDONG 510530 CHINA
Country: Israel Country: China
Contact: Mr.Oren Bechar of Contact: Elaine Ouyangl
Mr.Meir Adest
Phone: +972 9 957 6620#293 or+972 9 957 6620#131 phone: 020-2805 4025/135-702375852
FAX: +972 9 957 6591 " FAX: NA
Email: OREN,B@SOLARPDGE.COM Email: Elaiine.ouyang@jabil.com
Party Authorized To Apply Mark: Same Manufacturer
Report Issuing Office: � Cortland,
NY 13045 Gn-�
Control Number: 4004590 Authorized by:
for Thomas J.Patterson,Certification Manager
0%-
us
Intertek
This document supersedes all previous Authorizations to Mark for the noted Report Number.
Thia MNarimdon b Mork la for No oaddai.....of Inbrtoks Cllantantl la provided p....nt biho CONBdetlan agma-1 bofw.on Inbrbk and Its Clam Intortak,na,;,—IC ky and liability..
Ilmlbd b No1 and wntlltl.np f agroamenL Inbdekaac.apn no bblily to any pedy,sN.r Nan t.N.Chant In accoMonm wIN Noag"_L fat arty loan...p.n.or a.—II orsoalonod
II,No—of Inia A.thod.atlonf.Mork OMyN.Qlenl I!ouNedmdbp.rmlt rnpylnoor dintrib.V ofihi.AuNodmfion b wA.nd Nan.M In ib entlr.ry.U..of Inbrbk•.C.Nlladg.n markL
roaM4otl b the eondiflana lald out In Na ogre.....nd in OIL A.Nodradon to Mark My fu.ar..of-Inbdnh name for No solo arativadlaamontoi N.bolod malad.l,p dd,cl or a-1,,a mual
tint bo appmvctl in-dng by Intodak.Initlai Facbry AsoosamonL and Follow up 5arvl...ore for No puryoao of oasurin0 appmpdalc u.aBo of No Cadipragsn mats in ocmrdbnco vAN No
agro.men4 Nay aro not for No pu@osoa oI nad.dita audlty canaal and donot ndl elh.Ghent of lhoirobllgafbna In Nis r ,,.,L
Intertek Testing Services NA Inc.
545 East Algonquin Road,Arlington Heights,IL 60005
Telephone 800-345-3851 or847-439-560 Fax 312-283-1672
UL 1741 S)andard:for Safety for Inverters,Converters,Controllers and interconnection System
Equipment for Use With Distributed Energy Resources,Second Edition Dated:January 28,2010
CSA C22.2 107.1 Issue:2001/09/01 Ed:3 General Use Power Supplies-(R2011)
Standard(s): UL SUBJECT 1699B,Outline of Investigation for Photovoltaic(PV)DC Arc-Fault Circuit Protection-Issue
No.2,2013/01/14
CSA TIL M-07,Interim Certification Requirements for Photovoltaic(PV)DC Arc-Fault Protection-Issue
No.1,2013/03/11
ATM for Report 31888027CRT-001a Page 1 of 8 ATM Issued:13-Nov-2014 ATM for Report 3188027CRT-001a Page 2 of 8 ATM Issued:13-Nov-2014
` ED M3.15(1J -13)Mandatory ED 16.3.15(14an-13)Mandatory
3933 US Route 11
Cortland,NY 13045
Em Telephone:(607J 753-6711
Facsimile (607J 156-9891
www.moltek.com SolarEdge Technologies Ltd Letter Report 101703554CRT-001
June 20,2014 Letter Report No.101703554CRT-001 June 20',2014
Project Ng'.G101703554
• 3-ph Inverters:
Mr.Meir Adest Ph:+g72.9,957.6620 o SE9KUS/SElOKUS/SE20KUS when the.SolarEdge rapid shutdown cable labeled"MCI-CB-xxxx(-
SolarEdgeTes nologies Ltd email:meir.a@Ipolaredge.com
6 Ha'Harash St, x"which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is
HOD HASHAt/RO/N,ISRAEL any number,;inverter part number maylbe followed by a suffix
Subject: ETLZ'luation of SolarEdge Products to NEC Rapid Shutdown Requirements
This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554.
Dear Mr.Meir Adest,
If there are any questions regarding the results contained in this report,or any of the other services offered by
This letter represents the testing results of the below listed products to the requirements captained in the following Intertek,please do not hesitate to contact the undersigned.
standards: Please note,this Letter Report does not represent authorization for the use of any Intertek certification marks.
National Electric Code,2014,Section 690.f2 requirement for rapid shutdown. Completed by: Radhe Patel Reviewed by: Howard Liu
This investigation was authorized by signed Quote 500534459 dated 06/10/2014.Rapid shutdown test were Title: Engineering Team Lead Title: Staff Engineer
perform at SolarEdge Technologies Ltd,6 Ha'Harash St HOD HASHARON,ISRAEL and witness by Intertek � 2 /!14-- ')
personal on 06/17/�014.
Signature: _-------�J Signature
The evaluation covers installations consisting of optimizers and inverters with part numbers)listed below.
Date June 20 ,2014 Date: June 20 ,2014
The testing done has verified that controlled conductors are limited to not more than 30 volts and 210 volt-
amperes within 10 secondstof rapid shutdown initiation.
Applicable products:
• Power optimizers:
o PBxxx-yyy-zzzz;where xxx is any number,0-9,up to a maximum value whqre xxx=350;yyy
could be AOB or TFI;and zzzz is any combination of four letters and numbers.
o OP-XXX-LV,OP XXX-MV,OP-XXX-IV,OP-XXX-EV.;where xxx is any number,0-9.
o Papa,Pbbb,Pcec,Pddd,Peee;where aaa,bbb,ccc,ddd,eee is any number,0-9 to a maximum
upto aaa=300,bbb=350 ccc=500,ddd=600,eee=700.
o PW,Pyyy,Pzzz,Pmmm,Pnnn and P000;where xxx,yyy,zzz is any number,0-9 to a maximum
up to xxx=300,yyy=350,zzz=500;where mmm,nnn,000 is any number,0-9 to a maximum up to
mmm=405,nnn=300,000=350
• 1-ph Inverters:
o SE3000A-US/SE3800A-US/SE5000A-WS/SE6POOA-US/SE7600A-US/SE10000A-US/
SE11400A-YS when the SolarEdge rapid shutdown cable labeled"MCI-CB-xxxxx-x"which is part
of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-Kx is any,number;
inverter part number may be followed Iby a suffix
Pogo 1 of2
Tbis mPon la for In.cxclwlve una or tnledvl{s Cllvnt and Is provided pumuont b the agmamont bat—Inlortok and ila Cgont,Inontol.rosponciblliry and Iloblily on Ilmibd to the to—
and coodill—of tho agro—C Inbrtok aooumuo no nobility b any party,other Nan to the Cllanl in eomkanrn with gw agroomon4 branylaos,oxpariso or tlamago accoalanad by bo uae
of Chic ropom Only lion Client la oulh,r,d to p nr t copying ar dbbibWon of this roport,and than on�y,In im ooumty.My use of tho Intorbk main or no of Ito marks for iha solo or
atruoNsomo 11of lno Iwlatl rtwtadai,product br aoMro moat pmt bo oppm—In wddng by Inn 1 1,o boonmdono and toot roswm in bic mport ore rolavant only bo oompla taobd Tnls
mpott by Ibelftlooa not imply Not be malarial,pmtluctaraervice b or has ever boon untlaran Inbdok mNliwOon pmgmm
71/ l'`\
Page 2 oF2
Intartok Testing 5ervices NA,ine, so 121 2(11/1 t/1 n)inbrmativo
Intortok Tcsbng Sarvicas NA,Inc, So 12.1.2(11111f10)Inlormativo
g
So'a r ® SQ a r=I,' @ SolarEdge Power Optimizer
Module Add-On for North A(r)erica
P300 / P400 / P405
SolarEdge Power Optimizer __-- --- -_-_ ___ _----------------___-__ --- ------__ __ __
P300 P400 P405
Ifar 60-cell modules) (for 72&96-cell modules) (forthln film modules)
Module Add-On For North America NPDT - — --- ---- ---- -
RatedlnputDCPower 300 400 405 W
f� [�t f� Absolu�e Maximum Input Voltage qg ED 125 Vdc
P30Q / P400 / t 405 (Voc at lowest temperature)
MPPT Operating Range 8-48 8-90 12.5-205 Vdc
Maximum Short Circuit Current(isc) 10 Adc
Maximum DC Input Current 12.5 Adc
I Maximum Efficiency 99.5 ;
`- Weighted Efficiency 98.8 {
-Overvoltage Category___.___- '. --Al _.. _______-__.__..______ •-._
_-_ .__-_ - -- ____ -_-__ - -.' -
,(,t" I __ ( P.OPTIMIZER CONNECTED TO OPERATING INVERTER)
` Maximum Output Current
OUTP T DURING OPERATION POWER _
--- - 15 - Adc
_ 60 RS Vdc Max mum Output Voltage __ ' _._ _ _ _._-. ___ _._
IJ PTIMIZER DISCONNECTED FROM INVER'�ER OR INVERTER OFF{
r _.__ _.__ _ __.-__
Safely O tput)Voltag�er Power OP bmlzelr O 1 Vdc
p g
___ V P___ _.
STANDARD COMPLIANCE
EMC FCC Part15 Class B,IEC61000-6-2,IEC610DO-6-3
' '` •�°�0r - s Safety IEC62109-1(class II safety),UL1741
RoHS _ _ _ Yes
__ -- __..._—
Maxim um Allowed System Voltage 1000 Vdc
Pxxx-2 series 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in
Dimensions(Wx Lx H) 128 x 152 x 27.5/ 128x 152 x 3S 128x 152 x48/
'Pxxx-5 series 5x 5.97 x 1.08 5x 5.97x 1.37 Sx5.97x 1.89 , mm/in
- Weight(Including cables) Pxxx-2 series '. 950/2.1 gr/lb
Pxxx-5 series 770/1.7 930/2.05 93012.05 gr%lb
Input Connettar MC4 Compatible '
- Output Wire Type/Connector _ Double insulated;Amphenol
Output Wire Length 0.9513.0 1.2/3.9 m%ft
/' i•. I - Operating7emperature Range 40-+85/-40-+185 'C%-F
Protection Rating Pxxx-2 series IP65/NEMh,4 gr%Ib
Pxxx-5 series IP68/NEMA ff '�. gr%to
- Relative Humidity 0-100 °(
Pafetl STCpower afthe motlule Mptluic o(up 1p�sY.Dower roicrunrcallowM
PV SYSTEM DESIGN USING
ASOLAREDGE INVERTERI') SINGLE PHASE THREE PHASE 208V THREE PHASE 460V
Mini um String length -�_---_------_-- ---
8 10 18
(Power Optimizers)
PV power optimization at the module-level Maximum String Length zs zs so
(Power Optimizers)
Up f0 25%more energy Maximum Power per String 5250 6000 12750 1N
Superior efficiency(99.5%) Parallel Strings of Different Lengths Yes
- Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading or 0rientafions .
m i-ror onowotl u mm cans w m D�oo/e�sof eeoyesoowvoo m o tie:mew
- Flexible system design for maximum space utilization
- Fast installation with a single bolt
- Nest generation maintenance with module-level monitoring -
- Module-level voltage shutdown for installei and firefighter safety -
USA - CEe,vInNY - ITAL! - FRANCE 6},iAhl - CHINA - IS'BAEL - r.USTI-Jn U5
IRQNRIDGE ROOF Mouth System - AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s)shown below to the models described in the Product(s)
Covered section when jnade in accordance with the conditions set forth in the Certification Agreement and Listing
Report.This authorization also applies to multiple listee modgl(s)identified on the correlation page'of the Listing
Report.
This document is the property of Intertek Testing Services and is not transferable.The certification mark(s)may be
applied only at the location of the Party Authorized To Apply Mark
Applicant: IronRidge,Inc. Manufacturer: IronRidge,Inc.
' 1.495 Zephyr Ave 1435 Baechtel Road
Address: Address:
_.. Hayward,CA 94544 Willits,CA 95490
Country: USA Country: USA
Contact: Yann Schwarz Contact: Jim Norsworthy
Phone: (i300)227-9523 Phone: (800)227-9523
(t510)225-0973
FAX: (707)459-1833 FAY: (707)459-1833
Email: yschwarzoo ironridge.com Email: jnorsworthy@ironridge.com
Party Authorized To Apply Mark: Same as Manufacturer
Y Report Issuing Office: Lake Forest,CA
Control Number: 4007559 Authorized by:
for Thomas J.Patterson,Certification-Manager
E71.CLASSIFIED
QP US
Intertek
This document supersedes all previous Authorizations to Mark for the noted Repot Number.
IronRidge builds the strongest roof mounting system in solar.Every component has been tested to the limit Thka Nmhatlonm Mukkfor op tl Wv vatlnk tl oCgontontlk yhyaod pumuantm PM CoM0.*lbnopmo rob—P1—Inand lm Cponk lnmlmk's-Por My.nd RoWityam
.t WMMIk Nvkrmcandmndl-,or PM ogrvomant InkMk vsumoa no IW4 m Rl dy.odmr ,m In,Clknl inpccvd—n h Nvatlmomnnk for onyl—ary brd.-V.ocrosloned
and Proven in extreme environments. bylhv use arNk Nulbodmllon to Mmk Ohly..ClkMP,..ortrad m P.Mnf-tying or PIPWP dW Aft-.nm MOMmld.....VIP lk-f�y.Usavnnkdok'a Co.—
in.—no—far pw cam orvdwrllasmontsfms Nil.—n.,pmauclpraorvko must
Our ri 9 PP unique } g orous approach has led to ue structural features,such as curved rails and ,aria reinforced flashins wl tlppm etl lnwdlkp by lnm klni lFovmryA umon aM Fogow up Smv av artl tar vpuryovo of..-.opp n—usopo pr NO CmPq Pmurk In—damnwNNo oproomonl
0vy am nol kr PM cumppon of Pmdud6dgwbb anw and do not mf vo Pa Guenter lnalroblipallvnn amppacb
is also why our products are fully certified,code compliant and backed by a 20-year warranty. Intertek resting Services NA Inc.
545 East Algonquin Road,Arlington Heights,IL 60005
Telephone 800-345.3851 or 847-4395667 Fax 312-283-1672
Streggth Tested PE Certified UL Subject 2703 Outline of Investi gati on for Rack Mounting Systems and Clamping Devices for Flat-Plate
All components evaluated for superior Pre-stampedl engineering letters Standard(s); Photovoltaic Modules and Panels,Issue Number:1,October 4,2010
structural performance. available in most states. Product: xR Rails with Integrated Grounding.
Brand Name: N/A "
Models: - 51-61 GD-005,51-61 GD-005B,.51-5000-001,and 51-65401 '
Class A Fire Rating Design Software
Certified to maintain the fire resistance Online tool generates a complete bill of
rating Af the existing roof. materials in minutes.
IntegratedGrounding 20 Year Warranty
UL 2703 system eliminates separate Twice the protection offered by
module grounding components. w competitors.
ATM for Report 101541132LAX-002 Page 1 of 3 ATM Issued:10-Nov-2014
- - co teats twpn.r67 kmndpmy
I l �
IRON RIDOE Integrated Ground ing.System Installation Overview
Install Roof Attachments "
1` _ Install appropriate roof Bashing and/or standoff for roof type.
v - - Attach L-Feet to flashing or standoff.
Traditionally,solar modules are grounded by attaching -,
lugs,bolts or clips to the module frame,then connecting Prepare Rail Connections
these to a copper conductor that runs throughout the
array.This process adds time and cost to the installation, Insert splice into first rail,then secure with Grounding Strap and
and often results in improper grounding,creating self-drilling screw.
significant long-term safety risks.
Slide second rail over splice,then secure with opposite end of
The IronRidge Integrated Grounding System solves these Grounding Strap and self-drilling screw.
challenges by bonding modules,directly to the mounting
rails.This approach eliminates separate module
grounding hardware,and it creates many parallel Mount&Ground Rails
grounding paths throughout the array,providing
���= -` .Attach rails to L-Feet and level rails. -
greater safety for system owners.
Grounding Mid Clamp •Install one Grounding Lyig per row of modules.
Each Grounding Mid Clamp pierces through the -Connect Grounding Lug t0 grounding conductor
anodized coatings of both the module frame and g g g g '..,__.____,__-_-__
tha mounting tall to form gears electrical bonds,
which are repeated throughout the array.
Install Modules&Clamps —-- — ---
Install first module using End Clamps and Grounding Mid Clamps.
Install additional modules using Grounding Mid Clamps.
Finish row with a second pair of End Clamps.
Testing&Certification
y Cal Module Frame Compatibility
4 -r The IronRidge Integrated Grounding
/ F W System has been tested and ce ified to
Dimensionj Range
- UL 2703 by Intertek Group plc. - - -
4 t. A 310mm 510mm
' UL 2703 is a proposed UL standard
B 5 08mm(minimum)
� ', ti P p a
,:." for evaluating solar module mougtmg Any module frames whose parameters are not listed in the
or and Clamping devices.It ensures these provided table have not been tested for compatibility.
3 devices will maintain strong electrical and
mechanical connections over an extended
The Grounding Clamp has proven robust in grounding
60-cell and
44
period of time in extreme outdoor 72-cell solar module frames with box construction an a range of
environments. anodizafion thicknesses. g
2 The testing process closely mirrors that
4 All solar modules listed to UL 1703 and with frame construction
Grounding Strap �c • of UL 1703,the solar module testing within the parameters stated above are compatible with the
Grounding Straps are used to / --^" p p i
bond ralWo-call connections. / standard,including temperature and IronRidge Integrated Grounding System.
Thbyare onlyrequired onthe Grounding Lug humidity cycling,electrical and mechanical
rail with the grounding lug. A single Grounding Lug load testing,and manufacturing 'quality
_
connects an entire row 9 g W, r/
of PV modules to the reviews.
` -� grounding conductor
I
8431 Murphy Drive
Middleton,WI 53562 USA
V
Telephone:608.836.4400 S 608.831.9279
Starling Madison Lofquist, Inc.
1"'.—II,"�4 �r"'.,,itn d I I.......r,
L-
-.lhtertekxorri 5324 South 39'Street,Phoenix,Arizona 85040
tel:(602)438-2500 fax:(602)438-2505 www.smieng.com
IronRidge June 16,2014
In the basis of the tests undertaken,the sample(s)of the below product have been found to comply with the requirements of 1495 Zephyr Ave Page I of 11
the referenced specifications at the time the tests were carried out.
Hayward,CA 94544
Applicant Name&Address: IronRidge,Inc. Attn:Mr.David F.Taggart,Vice President Products
1495 Zephyr Ave. r
Hayward,CA 94544 Subject: IronRidge XR100 Rail,Roof Flush Mounting System—Structural Analysis
USA
Product Description: XR Rails with Integrated Grounding. Dear Sir:
Ratings&Principle Fire Class Resistance Rating:
Characteristics: -Flush Mount(Symmetrical).l Class A Fire Rated for Low Slope applications when using Type 1,2 We have analyzed the
e IronRidge XR100 Rail for toe subject solar module support system and
'and 3,listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Typei, determined that, for the configurations and criteria described below,it is in compliance with the
2 and 3,listed photovoltaic modules.Tested with a 5"gap(distance between the bottom the applicable sections of the following Reference Documents:
module frame and the roof covering),per the standard this system can be installed at any gap
allowed by the manufacturers installation instructions. No perimeter guarding is required. Codes:ASCE/SEI 7-10 Min.Design Loads for Buildings&Other Structures
International Building Code 2012 Edition
Models: 51-61GD-005,51-61GD-0058,51-5000-001 and 51-65-001 California Building Code 2013 Edition
Brand Name: IronRidge Roof Mount Other: AC428,Acceptance Criteria for Modular Framing Systems Used to Support PV
Relevant Standards: UL 2703(Section 15.2 and 15.3)Standard for Safety mounting Systems,Mounting Devices, Modules,dated.Effective November 1,2012 by TCC-ES
Clamping/Retentloh Devices,and Ground Lugs for Use with Flat-Plate Photovoltaic modules Aluminum Design Manual,2010 Edition
and Panels,First Edition dated Jan.28,,2015 Referencing UL1703 Third Edition dated Nov.18,
2014,(Section 31.2)Standard for Safety for Flat-Plate Photovoltaic Modules and Panels, The IronRidge XR100 Rail is an extruded aluminum section with an overall depth of 2.438 in.and a
Verification Issuing Office: Intertek Testing Services NA,Inc.
8431 Murphy Drive net area of 0.583 sq.iP- The rails are used to suppqrt solar modules,typically,on the roof of a
Middleton,WI 53562 building. See Exhibit A—attached. The rails are clamped to aluminum angle brackets that are either
Date of Tests: 08/27/2014 to 03/17/2015 attached directly to the TOOf framing or attached to a stand that is screwed to the roof framing. The
Test Report Number(s): 101769343MID-O0Irl,101769343MID-001a,101915978MID-001,&101999492MID-Oolarl-crl. rails are mounted acro.ss the slope with a small clearance(flush mounting)to the underlying roof
This verification is part of the full test reports)and should be read in conjunction with them.This report does not automatically structure. The installed solar modules ate at the same slope as the underlying roof structure.
imply product certification.
All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of
Completed by: Chad Naggs Reviewed by: Gregory Allen
Title: Technician 11,Fire Resistance Ti t I e: Engineering Team Lead,Fire Resistance the rails. The xnax=4m span of the rails is governed by either the mid-span flexural s)resscs or the
deflection requirement that the rail not come into contact with the roof.
Signature:
Signature:
Date: 03/30/2015 Date: 03/30/2015 The effect of seismic loads(for all design categories A-F)have been determined to be less than the
effect due to wind loads in all load conditions and combinations. Therefore,themaxinum allowable
spans for common load cases are shown in Tables 1,2&3 below for 0-6 degree slopes,Tables 4,5,
&6 below for 7-27 degree slopes,and Tables 7,;8&9 below for 28-45 degree slopes.
Th;sVellflcotion is for the exclusive use ofintenrel,'c client and is provided pursuant to rhc cy,--mentboavoon lotertek and its client lotarreks rcsponsibilay and liability ore
limited to the terms and conditions of the agreement.lrtenck assumes no liability to o,y vony,other thon to the Client ir.accordance with the --se
or detnege Mosloned by the use of this Verificopon.Only the Client is authorized to pennit rcpj,�,no or distribution ofthis Verfication.Any use of.(he Intencknarre or me ofirs
marks for thc5olc credvord—cot of the tested materiel,product arsemice must first be cppruimdin lylitilli byWert1k.The.be-1f.n,and r,
crlinspectidn results Staling Madison Lof`4-i-;Inc. Consulting Structural and Forensic Engineers
GFT-OP-1 I a(24-MAR-2014)
IronRidge June 16,2014 IronRidge Tune 16,2014
Mr.David F.Taggart Page 8 of 11 Mr.David F.Taggart Page 9 of 11
IronRidge XR100 Rail,Roof Flush Mounting System-Structural Analysis IronRidge XR100 Rail,Roof Flush Mounting System—Structural Analysis
Table 7-MPJ,tIMUM SPANS(inches)-Roof Slope 28 to 45 Degrees-Wind Zo�e 1 'fable 8-MA}C MUM SPANS('inches)-Roof Slope 2S to 4S Degrees-Wind Zone Z
XR101) Wind Ground Snow Load XR100 Wind Ground Snow Load
Pail Speed Rail Speed
Exposure mph P psf 10 20 3.0 io 50 60 70 8q 90 Exposure mph q psf 10 20 30 4P 50 60 70' 80 90
psf psf psf sf sf sf psf psf psf psf psf psf psf psf psf psf sf psf
100 '107 98 84 75 67 61 56 52" 49 46 1'00 107 98 84 75 67 61 56 52 49' 46
105 107 98 84 75 67 61 56 52 4 46 105 107 98 84 75 67 61 56 52 49 46
110 106 97 84 75 67 61 56 52 49 46 1.40 106 97 84 75 67 61 56 52 49' 46
120 101 94 82 74 67 61 56 52 49 46 120 101 94 82 74 67 61 56 52 49' 46
CateBgory 130 96 91 80 72 66 61 56 52 4 46 Cate6gory 130 94 91 80 72 66 61 56 52' 49' 46
140 91 88 78 7.0 65 60 56 52 49 46 140 88 88 78 70 65 60 56 52 49 46
150 87 85 76 69 64 59 56 52 49 46 150 83 83 76 69 64 59 56 52 49 46
160 '83 82 74 67 62 58 55 52 4 46 160 '78 78 74 67 62 58 55 52 49 46
170 '79 79 72 66 61 57 54 51 49 46 170 74 74 72 66 61 57 54 51 49 46
100 101 94 82 74 67 61 56 52 49 46 100 101 94 82 74 67 61 56 52' 49- 46
105 98 93 81 73 67 61 56 52 4 46 105 98 93 81 73 67 61 56 52 49 46
110 95 91 80 72 66 61 56 52 49 46 110 94 91 80 72 66 61 56 52 49' 46
120 '90 87 77 70 65 60 56 52 4 46 120 87 87 77 70 65 60 56 52 49- 46
Category 130 -85 84 75 6.8 63 59 56 52 4 46 CateCgory 130 81 81 75 68 63 59 56 52 49' 46
140 81 80 72 66 62 58 55 52 4 46 140 '76 76 72 66 62 58 55 52 49 46
150 '76 76 70 6.5 60 57 53 51 4 46 150 71 71 70 65 6 57 53 51 49' 46
160 '73 73 68 63 59 55 52 50 48 46 160 '67 67 67 63 59 55 52 50 48' 46
170 '69 69 66 61 57 54 51 49 47• 45 1;70 "64 64 64 61 57 54 51 49 47' 45
100 96 91 80 72 66 61 56 52 4$ 46 100 95 91 80 72 6 61 56 52 49' 46
105 93 89 79 71 65 61 56 52 49 46 105 91 89 79 71 65 61 56 52 49' 46
110 -90 87 77 70 65 60 56 52 49 46 110 87 87 77 70 65 60 56 52 49' 46
120 85 83 75 68 63 59 55 52 49 46 120 '81 81 75 68 63 59 55 52 49 46
CateDgory 130 80 80 72 6,6 61 58 54 52 4 46 CateDgory 130 75 166
5 72 66 61 58 54 52 49' 46
140 75 75 70 64 60 56 53 51 48 46 140 '70 0 70 64 6 56 53 51 48' 46
150 71 71 67 62 58 55 52 50 48 46 150 '66 66 62 58 55 52 50 48- 46
160 68 68 65 60 57 54 51 49 47 45 160 62 2 62 60 57 54 51 49 47' 45170 64 64 62 58 55 52 50 48 46 44 170 59 9 59 58 55 52 50 48 46' 44
Notes—see page I 1 Notes—see page 111
Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers
g_ -9-
IronRidge Tune 16,2014 IronRidge ,tune 16.2014
Mr.David F.Taggart )age 10 of 11 Mr.David F.Taggart Page 11 of l l
IronRidge XR100 Rail,Roof Flush Mounting System-Structural Analysis IronRidge XR100 Rail,Roof Plush Mounting System—Structural Analysis
Notes—Tabulated values arc based on the following criteria:
Table 9-MAX P�IUM'SPAIVS(inches)-Roof Slope 28 to 45 Degrees-Wind ion• 3 ,.
XR100 Wind -
Rail Speed Grour}d Snow Load 1. Building mean roof height=30 ft
2. Risk Category I
Exposure 10 20 30 4P 50 60 70' 80, 90
p ph psf 3. Solar module long dimension=67.5 in
n} 4 sf sf sf sf sf sf sf sf sf 4. Provide 2 in.clear between roof and rail
100 107 98 84 75 67 61 56 52' 49' 46 5. End cantilever span(max),=0.40 x maximum span tfrom above tables
105 107 98 84 75 67 61 56 52' 49 46 6_ No rail splices in end spas
110 106 97 84 75 67 61 56 52 49 46
120 101 94 82 74 67 61 56 52 49 46 7. No rail splices in middle 113 of interior spans
Category 130 94 91 80 72 66 61 56 52 49' 46 3. Single simple spanl(s). Spans listed in the tables above may be multiplied by 1.09 for
B 140 88 88 78 70 65 60 56 52 49 46 continuous rails of 3 or more spans.
150 83 83 76 69 64 59 56 52 49' 46
160 78 78 74 67 62 58 55 52 49' 46
Our analysis assumes that the rails,including the connections and associated hardware,arc installed
170 74 74 72 66 61 57 54 51 49' 46 ,. _
100 101 94 82 74 67 61 56 52 49' 46 in a workmanlike mariner in accordance with the"honR.idgc Roof Mount Installation Manual"by
105 '98 93 81 73 67 61 56 52 49' 46 [ronRidge and generally accepted standards of construction piactice. Additional information'is
110 94 91 80 72 65 61 56 52 49' 46 available at the IronRidge web site,h�onRidge.com. Verification of PV Module capacity to support
120 87 87 77 70 65 60 56 52 49 46 fhe loads associated with¢he given array shall be the responsibility of the Contractor or Owner and
Category 130 81 81 75 68 63 59 56 52 49- 46 Pot IronRidge or Starling Madison Lofquist.
C
140 76 76 72 66 62 58 55 52 49 46
ISO -71 71 70 65 6 57 53 51 . 49 46
160 67 67 67 63 59 55 52 50 48 46 The adequacy of the supporting roof framing is to be determined by others.
1;70 '64 64 64 61 57 54 51 49 47" 45
100 95 91 1 80 72 66 61 56 52 49' 46
105 91 89 79 71 65 61 56 52 49' 46 f 1case feel free to contact me at your convenience if you have any duestions.
110 87 87 77 1 70 65 60 56 52 49' 46 .
120 81 81 75 68 63 59 55 52 49 46
CateDgory 130 75 75 72 66 61 58 54 52 49' 46 Respectfully yours, `trS
140 70 70 70 64 60 56 53 51 #47
' 46 it
150 66 66 66 62 58 55 52 50 ' 46 o TRES
160 '62 62 62 60 57 54 51 49 ' 45 o WAFNEF
.�-
CIVI
1,70 '59 59 59 58 55 52 50 48 46 44 Tres Warner,P.E. No.4D 32
Design Division Manager 1• e �•.
Notes—see page�31 �srlONAt
Starling Madison Lofquist,Inc. Ponsulting Structural and Forensic Engineers Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers
-10- -11-
8431 Murphy Drive
Middleton,WI 53562 USA
Telephone:60B.836.4400 Starling Madison Lofquist, Inc.
Facsimile: 608.831.9279 «Ili S r r c r.r.r,i. .r n d ! „ n.i r (rt
www.Ihtertekxom 5224 South 39'Street Phoenix,Arizono 85040
z tel:(602)438-2500 fox:(602)438-2505 www.smieng.com
IronRidge June 16,2014
In the basis of the tests undertaken,the sample(s)of the below product have been found to comply with the requirements of 1495 Zephyr Ave Page 1 of l l
the referenced specifications at the time the tests were carried out. Hayward,CA 94544
Applicant Name&Address: IronRidge,Inc. Attn:Mr.David F.Taggart,Vice President Products
1495 Zephyr Ave.
Hayward,CA 94544 Subject: IronRidge X$100 Rail,Roof Flush Mounting System—Structural Analysis
USA
Product Description: XR Rails with Integrated Grounding. Dear Sir:
Ratings&Principle Fire Class Resistance Rating:
Characteristics: -Flush Mount(Symmetrical).)Class A Fire Rated for Low Slope applications when using Type 1,2 We have analyzed the IronRidge XR100 Rail for the subject solar module support system and
and 3,listed photovoltaic modules.Class A Fire Rated for Steep Slope applications with Typel, determined that, for the configurations and criteria described below, it is in compliance with the
2 and 3,listed photovoltaic modules.Tested with a 5"gap(distar)ce between the bottom the applicable sections of the following Reference Documents:
module frame and the roof covering),per the standard this system can be installed at any gap
allowed by the manufacturers installation instructions. No perimeter guarding is required. Codes:ASCE/SEI 7-10 Min.Design Loads for Buildings&Other Structures
International Building Code 2012 Edition
Models: 51-61GD-005,51-61GD-005B,51-5000.001 and 51-65-001 California Building Code 2013 Edition
Brand Name: IronRidge Roof Mount Other: AC428,Acceptance Criteria for Modular Framing Systems Used to Support PV
Relevant Standards: UL 2703(Section 15.2 and 15.3)Standard for Safety Mounting Systems,Mounting Devices, Modules,dated Effective November 1,2012 by ICC-ES
Clamping/Retentioh Devices,and Ground Lugs for Use with Flat-Plate Photovoltaic Modules Aluminum Design Manual,2010 Edition
and Panels,First Edition dated Jan.28,2015 Referencing UL1703 Third Edition dated Nov.18,
2014,(Section 31.2)Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. The IrouRidge'XRI00 Rail is an extruded aluminum section with an overall depth of 2.438 in.and a
Verification Issuing office: Inter8431 Murphy
rive cesNA,Inc. net area of 0.583 sq.ip. The rails are used to support solar modules,typically, on the roof of a
Middleton,
Murphy Drive building. See Exhibit A—attached. The rails are clamped to aluminum angle brackets that are either
Middleton,WI 53562
Date of Tests: 08/27/2014 to 03/17/2015 attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The
Test Report Number(s): 101769343MID-001rl,101769343MID-OOla,101915978MID-001,&101999492MID-001arl-crl. rails are mounted across the slope with a small clearance(flush mounting)to the underlying roof
This verification is part of the full test report(s)and should be read in conjunction with them.This report does not automatically structure. The installed solar modules are at the same slope as the underlying roof structure.
imply product certification.
All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of
Completed by: Chad Naggs Reviewed by: Gregory Allen the rails. The maximum span of the rails is governed by either the mid-span flexural stresses or the
Title: Technician II,Fire Resistance Ttie: Engineering Team Lead,Fire Resistance deflection requirement that the rail not come into contact with the roof.
Signature: Signature:
Date: 03/30/2015 Date: 03130/2015' The effect of seismic loads(for all design categories A-F)have been determined to be less than the
effect due to wind loads in all load conditions and combinations. Therefore,the maximum allowable
spans for common load cases are shown in Tables 1,2&3 below for 0-6 degree slopes,Tables 4,5,
&6 below for 7-27 degree slopes,and Tables 7,:8&9 below for 28-45 degree slopes.
This Verification is for the exclusive use of lntertek',client and is providedpursuant to the agreement benvren lntertek and its Client.kuenck's resp—hullry and liability arc•
limited to the terms and conditions of the ogreement lntertek ossumes no liability to ony pely,other thou to the Clienr in accordance with the agreement.forany loss,expense
or damageoccosioned by the use of;his Verification.Only the Client is authorized to permit ca m or distributions thes Vesication.An use •the mterteknome or one s its - --- - _ - ---
f Y A PY 9 f f Y I f - ..
marks for the sale or advertisement of the tested material,product crscruice must first be approved in writing by lntertek.The ObsCNotions and test/hs'Pettion resins Starling Madison Lofquist,Inc. Comuhing Structural and Forensic Engineers
referenced in this Venfcation are reRvont only rb the sample tested/inspected.This Verifcath,r?y¢self does not imply thor the material,product orsemn,is or hos ever been
under an lntertek crrtificarion prog—r. '
GFT-OP-11a(24-MAR-2014)
IronRidge June 16,2014 IronRidge June16,2014
Mr.David F.Taggart Page 5 of 11 Mr.David F.Taggart Page 6 of 11
IronRidge XR100 Rail,Roof Flush Mounting System-Structural Analysis IronRidge XR100 Rail,Roof Flush Mounting System-Structural Analysis
Table 4-MAXIM SPANS(inches)-Roof Slope 7 to 27 Degrees-Wind Zon'-= Table 'UUM SPACES('inches)-Roof Slope 7 to 27 Degrees-Wind Zone 2
XP.100 Wind XR100 Wind
Rail Speed Ground Snow Load Raii Speed Ground Snow Load
10 20 30 {0 50 60 70 8q 90 Exposure ph psf 10 20 30 4P 50 60 70 80" 90
Exposure mph 0 psf
psf psf psf sf psf psf psf psf psf q psf psf psf psf psf psf psf psf psf
100 -112 97 83 72 64 58 53 49 46' 43 100 106 97 83 72 64 58 1 53 49 46 43
105 112 97 83 72 64 58 53 49 46 43 105 102 97 83 72 64 58 53 49 46 43
110 112 97 83 72 64 58 53 49 46 43 110 97 97 83 72 64 58 53 49 46' 43
120 112 97 83 72 64 58 53 49 46 43 120 90 90 83 72 64 58 53 49 46' 43
CateBgory 130 112 97 83 72 64 58 53 49 46 43 Cate go 130 '83 83 83 72 64 58 53 49 46' 43
140 '105 97 83 72 64 58 53 49 46 43 140 77 77 77 72 64 58 53 49' 46 43
150 98 96 82 72 64 58 53 49 46 43 150 73 73 73 72 64 58 53 49 46 43
160 92 92 81 72 64 58 53 49 46 43 160 68 68 68 68 64 58 53 49 46 43
170 '87 87 79 71 64 58 53 49 46 43 170 64 64 64 64 64 58 53 49 46 43
100 '112 97 83 72 64 58 53 49 46 43 100 '91 91 83 72 64 58 53 49 46" 43
105 112 97 83 72 64 58 53 49 46 43 105 '87 87 83 72 64 58 53 49 46' 43
110 112 97 83 72 64 58 53 49' 46 43 110 '83 83 83 72 64 58 53 49 46' 43
120 103 97 83 72 64 58 53 49 46 43 120 76 76 76 72 64 58 53 49 46 43
Category 130 96 95 82 72 64 58 53 49 46 43 Category 130 71 71 71 71 64 58 53 49 46 43
C 140 89 89 80 71 64 58 53 49 46 43 C 140 66 66 66 66 64 58 53 49 46' 43
150 '84 84 78 70 64 58 53 49 46 43 150 '62 62 62 62 62 58 53 49 46' 43
160 79 79 76 69 63 58 53 49 46 43 160 58 58 58 58 58 58 53 49 46' 43
170 74 74 74 67 62 57 53 49 46 43 1;70 '55 55 55 55 55 55 53 49 46' 43
100 '112 97 83 72 64 58 53 49 46' 43 100 84 84 83 72 64 58 53 49 46" 43
105 108 97 83 72 64 58 53 49 46 43 105 80 80 80 72 64 58 53 49 46' 43
110 103 97 83 72 64 58 53 49 46 43 110 '77 77 77 72 64 58 53 49 46 43
120 '95 95 82 72 64 58 53 49 46 43 120 70 70 70 70 64 58 53 49 46' 43
Cato 130 88 88 80 71 64 58 53 M443
CatDory 130 65 65 65 65 64 58 53 49 46 43
140 82 82 78 70 53 58 53 140 61 61 61 61 61 58 53 49 46 43
150 '77 77 76 6.8 62 58 53 150 57 57 57 57 57 57 53 49 46' 43
160 73 73 73 67 61 57 53 160 53 53 53 53 53 53 53 49 46' 43
170 "68 68 68 65 60 56 53 170 50 50 50 50 F 50 F 50 50 1 49 46' 43
Notes—see page 11 Notes—see page11
Sl
Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers Starling Madison Lo�quist,Inc. Consulting Structural and Forensic Engineers
-5- -G-
IronRidge dune 16,2014 IronRidgc .tune 16,2014
Mr.David F.Taggart age 7 of 11 Mr.David F.Taggart Page I 1 of 1 I
IronRidge XR100 Rail,Roof Flush Mounting System-Structural Analysis h•onRidge XRl00 Rail,Roof Plush Mounting System—Structural Analysis
Table 6-MAFIMUM SPANS(inches)-hoof Slope 7 to 27 Degrees-Wind Zone;3 Notes—Tabulated values arc based on the following criteria:
XR100 Wind Grou d Snow Load 1. Building mean roof heir h =30 ft
Rail Speed R 2. Risk Category I � }
p nip p 10 20 30 4 50 60 70' 80 90 3. Solar module bong dimension=67.5 in
Exposure h Q sf sf sf sf sf sf sf sf sf sf 4. Provide 2 in.clear between roof and tail
105 '83 87 83 72 64 58 53 49 46" 43 5. End cantilever span(mas),=0.40 s maximum span from above tables
105 '83 83 83 72 54 58 53 49 46 43 6. No rail splices in end spans
110 80 80 80 72 64 58 53 49 46 43
120 '73 73 73 72 64 58 53 49 46 43 7. No rail splices in middle 1/3 of interior spates
Category 130 68 68 68 68 64 58 53 49 46 43 8. Single simple span(s). Spans listed in the tables above may,be multiplied by 1.08 for
B 140 63 63 63 63 63 58 53 49 46 43 continuous rails of 3 or more spans.
150 59 59 55 59 59 58 53 49 46' 43
160 '56 56 M66
56 56 56 53 49 46' 43
1T052 52 52 52 52 52 49 46` 43 Our analysis assumes that the tails,including tite connections and associated hardware,arc installed
100 '74 74 72 64 58 53 49 46' 43 lit a worknianlikc inalmer in accordance With the"IronRidge Roof Mount Installation Manual' by
105 71 71 71 64 58 53 49 46 43 fronItidge and generally accepted standards of construction pl:aelice, Additional information is
110 68 68 68 64 58 53 49 46' 43 available at the IronRidge web site,lronRidge.com. Verification of PV Module capacity to support
120 '62 62 62 62 58 53 49 46' 43 the loads associated with ithe giv{n array shall be the responsibility of the Contractor or Owncr acid
Category 130 58 58 58 1 58 58 53 49 46 43 }lot hronRidge or Starling Madisou Lofquist.
C 140 54 54 54 54 54 54 53 49 46' 43
150 '50 50 50 50 5P 50 50 49 46 43
160 47 47 47 47 47 47 47 47 46' 43 The adequacy of the supporting roof framing is to be determined by others.
1,70 44 44 44 44 44 44 44 44 44' 43
100 68 68 68 68 64 58 53 49 46' 43
105 65 65 65 65 64 58 53 49 46 43 Please feel free to contact me it ypur convenience if you have any questions.
1.10 '62 62 62 62 62 58 53 49 46 43
a
120 '57 57 57 57 57 57 53 49 46' 43 - J
Category 130 53 53 53 53 53 53 53 49 46' 43 Respectfully yours, " a
D 140 '49 49 49 49 49 49 49 49 46 43 y i�t jr z1s c
150 46 46 46 46 46 46 46 46 46 43 y o TRES
160 '43 43 43 43 43 43 43 43 43 43 WASHER
1,70 41 41 41 41 Al Al Al Al 41 41 Tres Warner,P.E. A No.4a432 "�1
Design Division Manager s• SF �.9 t, P
Notes—see page;ll pF�sS Al
t"� s
'rrnmw,.,v
Starling Madison Lo€quist,Inc. Consulting Structural and Forensic Engineers Starling Madison Lofquist,Inc. Consulting Structural and Forensic Engineers
-7- -1i-
E-Mount Lag I QMSE - LAG E-Mount Lag Installation Instructions
InstallationTools Required:tape measure,roofing bar,chalk line,stud finder,caulking gun,sealant compatible with roofing materials,
THIS EDGE TOWARDS ROOF RIDGE INo DESCRIPTION OTYJBOX drill with 7/32"long-style bit,drill or impact gun with 1/2"socket
I FLASHING,9"X 72''X.040",5052,MILL I • • •
2 OBLOCK,CLASSIC,A36Q.1 CAST Al.MILL 1
3 PLUG,SEAUNG,5/16'X 718',EPDM/18-B SS 1 `-
4 LAG SCREW,HEX HEAD,Stlex 5A/2",18-8SS 1
5 WASHER,FENDER,5/I6"IDXI-1/4"OD,IMSSI )
RACKING COMPONENTS ?'?
NOTINCLUDED �:ss ; � ":�/ t �
5
-- --- �
w
- -
II ate,choose,and mark centers of('afters to�e Carefully lift composition roofshingiewith roofing Insert flashing between 1st and�2nd course:Slide
mounted.Select the courses of shingles where bar,just above placement of mount Remove nails up so top edge of flashing Is at least 3/4"higher
t mounts will be placed, as required.See"Proper Flashing Placement'on than the drip edge of the 3rd course and lower
next page. flashing edge is above the drip edge of 1st course.
Mark center for drilling.
i
4
9.00--._.—__._..,.
a
OT
'
1.29 oulckMountn•.i`
QMSE-LAG:QMPV E-MOUNT ( ' £
AVAILABLE IN MILL,AND {
WITH LAG BOLT �r £"1" *8 "Tv
BRONZE ANODIZED FINISHES
4,/9 uuus nes"vnsesreahen: q e
own.mowuawwcwa SIZE ORAWNBY: 0FM REV �} ., j �+f.
„e„o.,...o�. w rn o uc A orate 6 m mta 1f f
r=w ) T£ rSa
4 3 2 Using
Lag pull-out(withdrawal)capacities(Ibs)In typical lumber.
drill with 7/32 bit,drill pilot hole Into roof Clean off any sawdust,and fill hole with sealant Slide the flashing Into position.11lnsert the rubber
Lag Bolt Specifications ` and rafter,taking care to drill square.to the roof. compatible with roofing materials. plug into the QBIock cavity.
Do not use mount as a drill gulde.Drill should be
spad6.cm.Ily 5116-.h.dp.r"..dd.pm S/IV,hve per V lhread d.p6• 'long style bit,aka'aircrxft extension bit'to drill s
qo.e.Fr.L.,xh s6 1 - 798 26. 1�"deep hole Into rafter.
qavelm F1c Soule As - 70s vs
F hwnn Spruc.,Lod,,I.Pin.(MSR 1650 to hl,.,) AS 7.5 135
s PI As 6a6 212
S.- Pln. .56
�3 e
921 aa7 .,. �3`: a t"^ e3 ^' ° r it
$pram,Pule.Pr .42 615 205
Spruw.Pln.,Ph(E.f2milllon pal and ni0hor grad..of MSRand MEL) .6a 796 266
Sourtor.Amedcan Wood Cetmell,NDS.2005,Tabl.112 A,1132A
Notes: ;
1)Thread must be embedded Ina mfterar othe—cluml roofinember.
7J5<e NDS Table 115.1C forrequlred edge dismnms. t „" :r 3 if)
, Slide the washerand the L--foot(not induded)on>� Using a 1/2 inch socket on an impact gun doe �
R E<,P E c T -H< <, _,_ thg lag screw. the lag screw until the QBlock stops mtafing easily.
DO NOT over-torque.
BI 7.2.3-31 Sep•2014,Rev 1 BI 723-31 Sep-2014,Rev 1
DIAGRAM-TYPICAL CONFIGURATION
Product Datasheet
ENERGY
,;,scaoZIe ,'_ :r Shielded eats
INTERNET
7'
s ,kj --........
� • • •• 0 • e s¢t � £h ' .;ate® ,ism
MEN
6"A j locus k1 ` ® "MMUM
Oil inuml
R ynciolms
CE
ELECT ICAL
e o tf I Y` S ET
ems L
INVERTER(S) FGATE 720
PV ARRAY
DIMENSIONS
t
SOCKET METER
' METER BASE LOCUS ENERGY COMM MODULE METER MODULE
of
The L6ate 120 combines arevenue-grade,solid-state power meter with an advanced communications gateway. a 6951n 6.31 in
These components work in cojljunction to remotely monitor the performance of residential solar energy installation o
regardless of panel or,inverter type.The LGate 120 is a one-piece completely under glass meter which installs _
easily using a standard socket base.Performance data is uploaded in near real-time to the Locus Energy So1ar0S
monitoring platform which provides a suite of tools and analytics for asset managers. 5.46 in
+- 6.001n
Z30 in —
DATA COLLECTION
AC energy data is collected by,the meter and passed to the communications module.Additional system performance
data can be collected directly from meteorological sensors and supported inverters via availagle RS-485 or Zigbee
connections.All data is stored in non-volatile memory and then attomatically uploaded to the SolarOS and SPECIFICATIONS
SolarNOC platforms.
Processor ARMS etnbedded Cop Accuracy ANSI 1220(Class 02%)
Os Custom wrslon or tanux 2.6,OTA tirmwere updates Voltage Inputs 120-480 VAC
NETWORK CONNECTIVITY Memory 128MeRAM Max.Current input 200A
Display LCD screen Service Tyoe Single chase,60 He
The communications gateway inside the LGate 120 supports plug a9d play connectivity through a cellular or available Socket Type 2s
Ethernet network connection.Once the unit is installed and powered on,it will immediately begin transmitting data
without any configuration.For maximum reliability,the communications gateway will automatically route uploads Enclosure NEMA3R Type
between the wireless and wired connections if either of themetworks are unavailable. weight See ANSI 1220 class 02%
Dimensions 6.95'x 6.5'x 7.3" FCC Part 158
Environment -20 to 60C,all-weather PTCRB
FEATURES warranty 5 year ilmited warranty AT&T Carrier Compliance
ANSI C12.20 power meter Easy,low cost installation
Leate120-3Gx Uiato120-SGi
RS-485 and Zigbee inputs Doesn't req{ire entrance into the building Model W..., LGata120-SGyCellular-3,a 6sM ✓ ✓ ✓
GSM cellular or Ethernet connectivity Plug and play activation RS-485 2 and 4 wire ✓
• Over the air firmware updates LCD,display Medbue ✓
Zigbee J
Ethernet RJ-4510/100,DHCP/Static ✓
Single Meter Sockets -Without Bypass Single Meter Sockets -Without Bypass
` 125&200 Asap 125&200 Amp
Application
• Single meter position
Receive ANSI C12.10 watthour meters
" Surface or flush mount(see chard
X` Construction 011 F Flush Mount I=Ya
�. Rippg type lU)204 MS68-2"Conduit Hub to=+h'
- NEMAType 3R ® fU)207 MS68A-MS73+MS68 4F-2"-t/a
e�f +f •ANSI 61 gray E-coat finish "L 927 MS73-ALScrew Type Ring 4F=2 -th"-1Va'-1'
• , 9 y 6 4G®2+h•_2„_i,fi•_1y•
a •AI)iminum snap ring included SF-Semi Flush Mo nt Top Provision=See Chart
SS-Stainless Steels
Standards Accessories
`. UL 414 Listed 511h Jaw Kit-50365
•ANSI C12.7 200ATriplex Ground-ETR200 Knockout Layouts
011(closed) U204(open) AW Hub
Pmr/uPC Coming -Amp Service Conoecliens Fig.1 Fig-2
Number Number Fmialt Jaws Type Accasz Una Land Nmarul
Top,Provision Top Provision
70205142000 Oil 125 -4 10/3W OH%gG #14-2/0 #14-2/0 #14-2/0 ""
75205142040 Oil 125 4 10/3W OH/UG #14-2/0 #14-2/0 #14-2/0
7B205142045 Oil MS73 Us 4 10/3W OH/UG #14-2/0 #14-2/0 #14-2/0
7B205142050 Oil SF 125 4 10/3W OH/UG #14.2/0 #14-2/0 #14-2/0
78205144030 927 100 7 30AW OH/UG #14.1/0 914-1/0 #14-2/0
720515600 204 200 4 103W ON #6-250MCM 4-250MCM #6.350MCM Q
7862051560220 204F 200 4 70/3W ON #6.250MCM #6.250MCM #6-350MCM
79205156030 204FMS73 200 4 10/3W OH #6-250MCM #6-250MCM 46-350MCM
76205156040 204 MS88 2DO 4 10/3W OH #6-250MCM 46.250MCM A-,35UMCM 0
78205156035 204 MS68A 200 4 10/3W OH 06-250MCM 46-250MCM #6-350MCM �1
78205108490 2D4 MS73 200 4 1013W OH #6-250MCM #6-250MCM #6-350MCM 4F '
79205156005 U204 200 4 10/3W us #6.250MCM 06-250MCM #6-350MCM 4F 4F - 4F
70205156045 U204F 200 4 10/3W UG #6.250MCM #6-250MCM #-35MCM aa: 4F
78205156060 U2DQFMS73 200 4 10/3W UG #6-250MCM #6-250MCM #6.35OMCM to .bin;:
78205156070 U204MS73 200 4 10/3W UG #6-250MCM 46-250MCM #6-350MCM
7 820515 6 7 40 U207 200 7 30/4W OH/UG #6-250MCM 46-250MGM #6-250MCM
1A
70ZO5155170 U207F 200 7 3014W UG #6-250MCM 45-250MCM #6.250MCM
78205156180 U207 MS73 200 7 30/4W OH/UG #6-250MCM #6.250M¢M #6-250MCM
ParWPC cam", -Overall Dinummimm- ToP Knockout
Number Number Height Width Depth Provision Layout Fig.3 Fig.4
7820514200 gi7 12' 8" 0 Hub Fig,1 Top Provision
78205142040 077 F 12' 8' 4t/t"e" 2""m max KO flg.1 Top Provision
78205142045 Oil MS73 12' 8' 4'/e- AW Hub Fig.1
7B205142050 Oil SF 12' 8' 4/e' 2-max KO Fig.1
78205144030 927 17' 8" 41/,' AW ljub Fig.1
78205156000 204 15" 8" 41/s" AW Hub Fig.2
78205156020 204 F 15' B' 6" 2"max KO Fig.2
78205156020 204 F MS73 is, 8" 6" 2"max KO Fig,2
78205156040 204MSSO 15' 8" 41/e- AW/24Hub Fig.2 O 4F 0 4G
78205156035 204WIS68A 15" 8' 41/a" AW/2"Hub Fig.2
782051OB490 204 MS73 15' B' 4t/a' None Fig.2 1.
78ZO5156005 U204 15, 12" 41/e" None Pig.3
78205156045 11204 F 15' 12" 5" (2)2"max KO Fig.3 4G
N 4F 4G
7820515600 U204 15 12" 6" None Fig.3 4F :eu T�.'� 4G bam
4G
7820515607 MS73 0 U204 MS73 15'' 12' 41/e' None fig.3 O 'a°•
78205156140 U207 18' 12" 5" AW Hub Fig.4 AIC Now:
78205156 7 7 0 U207F 78' 12" 5" 2�7a"max KO Fig.4 Far shortcimuitcurrent 4G 1W 4G 2A
7B205156180 U207,MS73 18" 12" 5' AW Hub Fig.4 wrings see page 131.
Dam subject 10 change without notica.Consult local utility for area accopmnco.All dimension;are in inches. Data subject to change without notice,Consult local utility for area accaptanco,All dimensions are in inches.
B-Line 5 Meter Mounting Equipment Mato Mounting Equipment B-Line
EOERGY
October 22nd,2013
This letter is to certify that the LGate 120 and LGate 320 are communication boards built into the Vision
Meter 2S CL200 and 16S CL320 socket meters,xespectively. Each of these meters was certified to the
ANSI C12.20(class 9.2%)standard by Underwriters Laboratory on June 7,2013 as part of the Vision
Meter Family(Project Number 12CA71134,Job Number 1001541515,and Report Number R12CA71134-
ANSI).
ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility
and PV monitoring applications.These tests cover both meter accuracy as well asseveral safety
standards including electrical and environmental safety,as well as resistance to various types of
mechanical shock.As electrical socket meters are generally installed and maintained by trained and
certified professionals,ratherthan consumers,they do not fit the typical criteria for additional types of
UL or IEC certification.
If you have any further questions regardingthe product certification of any Locus Energy LGate-branded
device,please contact us at supportPocusenergv.com.
The Locus Energy Team
Locus Energy,LLC
www.locusenergy.com