Loading...
HomeMy WebLinkAbout08/08/2019 - James DeVellis (DEVELLIS ZREIN INC.) Comment - 481 Sutton Street DeVellis Zrein Inc. PO Box 307 Foxboro, MA 02035 Tel. (508) 473-4114 Fax. 774-215-0631 www.develliszrein.com August 8, 2019 Lt Michael Beirne North Andover FD 795 Chickering Rd. North Andover Ma. 01845 Jean Enright, Planning Director Town of North Andover 120 Main Street North Andover, MA 01845 Re: North Andover Senior Center Response to Fire Department Review Comments Dear Lt. Michael Beirne and Ms. Jean Enright, This letter has been prepared in specific response to the fire department comments received to date from the initial filing and the subsequent submission of the above referenced project with the Planning Board. The initial response letter was a compilation of all of the department and consultant review comments received. This letter addresses just the fire department comments. I apologize that the initial response mistakenly omitted some comments related to items within the building. Accompanying these comments is a revised swept path analysis diagram (Drawing Al rev 8-8-19) showing the North Andover fire truck with the specification provided by the town. The drawing indicates that the truck can either enter past the main lot or enter into the main lot and leave without the wheels touching the curbs or the parked cars. There are areas where the bumper overhang crosses over the 6-inch curb; however the wheels do not come in contact with the curbing. The wheel path is shown on the diagram within the colored path staying within the pavement. There are no poles or trees to obstruct this should the bumper extend over the curb. In addition, I added a 50 foot and 100 foot radius from the building for your reference. The following are the numbered comments and the responses in bold type: 1. Project must meet requirements of MGL148,527CMR,NFPA 1 and NFPA 101. Response: Acknowledged and agreed to 2. Project-specific site safety plan be implemented upon commencement of construction activities in accordance with 527CMR Ch.16 and NFPA241 Response: Acknowledged and agreed to 3. Bi-directional amplifier/emergency responder cormnunications system installed in accordance North Andover Senior Center DeVellis Zrein,Inc. August 8,2019 with 780CMR 916. Response: Acknowledged and agreed to 4. Fire protection systems be installed in accordance with 780 CMR Ch9, MGL 148 26G and NFPA 13. Response: Acknowledged and agreed to 5. Radio master box connected to North Andover Public Safety [NAPS] dispatch center via the North Andover FD radio box system be installed and connected to fire protection systems. The NAPS dispatch center will only monitor alarms. Any supervisory and/or trouble alarms will need to be monitored by an approved monitoring company in addition to the radio box connection in accordance with 527CMR and NFPA72. Response: Acknowledged and agreed to 6. A secured key access box will need to be installed in accordance with North Andover By-Law 69-8.1 7. Response: Acknowledged and agreed to 7. An elevator which is large enough to accommodate an EMSstretcher be installed in accordance with 780CMR. 8.A swept path analysis be performed of the site and parking areas to ensure FD apparatus has adequate access to the building in accordance with 527CMR Chl8 8. A swept path analysis be performed of the site and parking areas to ensure FD apparatus has adequate access to the building in accordance with 527 CMR Ch 18 Response: Swept path analysis plan attached to this response as described above. 9. Because the Senior Center will be a town building, we will monitor the supervisor and trouble alarms through dispatch. Response: Acknowledged and agreed to Thank you for your continued assistance. If there are any outstanding items upon review of my letter, please email me or call me at 781 771 8104 to discuss. Sincerely, DEVELLIS ZREIN INC. Q ,30/4&� s J eVellis, P.E. (/a'n al Copy: Project Team 2 100 FT FROM BUILDIN _ T -r-r = -- —(PUBLIC-6PWIDfi) 1 _ _50-F-T--FRONT BUILD i i 40.17 \ % 2 S70RY 8.00 18.96 BLMW I � z North Andover Fire feet Width : 8.50 Track : 8.50 J Lock to Lock Time 6.0 Steering Angle : 40.3 r� c4 - i '� !� A `, .— 01 20 ao' so'i Job#: cMi �.�w�,.,,,.,,��., s�rcn No. A-1 Dm-by. JJD Checked by. TOG Date: 07.24.19 Rv.08.8.19 DeVellis Zrein Inc. Nunn n"eo�®� Scale: 1.=" Title: FIRE TRUCK TURNING TEMPLATES