Loading...
HomeMy WebLinkAboutAs-Built Site Plan Sheet - As-Built Plan / Installation Certificate Form - 0 Riverview Street A B C D E F G H REMOVE AND DISPOSE _-- #% OF TREE AND STUMP a 3'X6'CONC.LANDING PAD -4 =, 4 t{ ;` (TYP.OF 3) hk REMOVE AND DISPOSE OF EXISTING 6 (TYP.OF 2) _ 00 ;__ 8 FENCE WITH FOOTINGS TO ALLOW FOR -3 - -- ms 4 m C-3 18"GRAVEL MOW STRIP CONSTRUCTION OF ELEC.DUCTBANK. - s ��- A� s 4 4 _ Fm APPROX.LOCATION FOR 40'x8'TEMPORARY BACKUP GENERATOR- - sssE �- sssm E t` PROVIDE APPROX.178 LF NEW 7 FT. ON TRAILER.FINAL LOCATION SHALL BE STAKED IN FIELD FOR - = HIGH CHAIN LINK FENCE WITH 4 FT. �€ � mmmmmm mE � REVIEW AND APPROVAL AND ENGINEER REV VAL BY OWNER / OF CLEARANCE TO TRANSFORMER _ � � I�t1 = � _ ■ �� SECONDARY TERMINAL BOX =1 a s aaaa---- ,H 200-FT RIVERFRONT AREA - `. --' `� ♦ 32 - P ,_ - �Vc4iV��„4 -Vi-- - - - - - - - - -- 6 PROTECT EXISTING SUBSURFACE z - ———— °. ♦ PIPES AND DRAINAGE STRUCTURES o -- ...... — b_ _ 1L= e --- 4 —— t� APPROX.162 LF A r FIBER ROLL a _ ' // °34 w 'b Via- /,/' - ° --° r •_�, - R m = - - /. C_3 TEMPORARY 6"LAYER CRUSHED _ ��� /•/ �_�_ �` `� STONE-REMOVE AND DISPOSE / 1 35 =AT END OF CONSTRUCTION _ t m [ 6 / . o _ •�__ - RONT FROM _ —/_ 8 g 10'WIDE DOUBLE LEAF C_3 O i { ;.-LOCKABLE SWING GATESq- C) O w (TYP.OF 2) ( Q Q OU + a ---- W _ +- r __ __ _ __ - - 3a=55_ a o �__ - ----- --- `- _ -- -- -- _--------- - ---- - - - _------- - - - 2 i{ OS 9.81 - Cif # N:30 343. ♦♦ o I, # 7546 .64 LU PROTECT EXISTING TREE t_ 3 c Z I LIMIT OF REMOVAL AND c EXISTING EQUIPMENT AND CONC.PAD I I -=% REINSTALLATION OF SLOPED to U) SHALL BE REMOVED AND DISPOSED, LnI _'- - _ GRANITE CURB w SEE SHEET E-3 o LIMIT OF REMOVAL AND REINSTALLATION } - ♦ Y STABILIZED CONSTRUCTION ♦♦ �Qa e se � 3 z OF SLOPED GRANITE CURB __ i�\ ENTRANCE �0016. PROTECT EXISTING GATE a - - `�♦ '' — — SAWCUT AND MATCH _ g EXISTING PAVEMENT CATCH BASIN FILTERS c23 ♦e `` _ _ '' 1 w ♦_ m o APPROX.5 LF e == FIBER ROLL - -e SWITCHGEAR CONC.PAD w �, e _, ELEV.=36.67 RIVERSIDE ._ - 3 o SEE STRU.DRAWINGS Of PUMP STATION = _ LEGEND PROTECT EXISTING 84"RCP CULVERT Q NOTES: E ` r-j CATCH BASIN FILTER.SEE z 1. CONTRACTOR SHALL VERIFY ALL PROPERTY AND SURVEY INFORMATION. _ - ♦ _ - - _ L__I DETAIL 2 ON SHEET C-3 CONTRACTOR IS RESPONSIBLE FOR CONFIRMING GRADES AND LOCATION 4 REMOVE AND REINSTALL APPROX = OF UTILITIES. MAJOR DISCREPANCIES ARE TO BE BROUGHT TO THE - / ♦ C . 3 FIBER ROLL o ATTENTION OF THE ENGINEER. Ln1 ♦♦ - 220-LF SLOPED GRANITE CURB 2. CONTRACTOR SHALL BE RESPONSIBLE TO IDENTIFY AND PROTECT ALL - _ i REMOVE AND DISPOSE o ON-SITE STRUCTURES AND VEGETATION TO BE RETAINED ON THE SITE OF EXISTING FENCE o o THROUGHOUT THE CONSTRUCTION PROJECT. I - A• e= COLD PLANE TOP 2-IN BIT.CONC.PAVEMENT AND LAY NEW 2-IN TOP COURSE BIT.CONC.PAVEMENT(TYP.) ? 3. LOCATIONS OF BURIED UTILITIES,VAULTS AND CONCRETE PADS ARE _ REMOVE AND DISPOSE O' o APPROXIMATE ONLY.FINAL LOCATIONS SHALL BE DETERMINED IN THE - --- --_ - OF EXISTING TREE �0 FIELD AFTER STAKING BY THE CONTRACTOR BASED ON ACTUAL SITE 100-FT WETLAND BUFFER ZONE o w CONDITIONS AS APPROVED BY THE ENGINEER. - r a ♦ 9 LIMIT OF STRUCTURE 0 0 4. ALL DISTURBED AREAS NOT COVERED WITH PAVEMENT,PADS,CURB, r C-3 TEMPORARY 6"LAYER CRUSHED Q 0 o MULCH,RIPRAP,PLANTINGS,CRUSHED STONE OR STRUCTURES SHALL ♦ / _ STONE-REMOVE AND DISPOSE REMOVAL AND DISPOSAL 3 i RECEIVE 6"LAYER OF LOAM AND SEED AS SPECIFIED,UNLESS NOTED -- L `_- AT END OF CONSTRUCTION OTHERWISE. LIMIT OF COLD PLANE 3 0 1 o a 5. ALL ITEMS TO BE REMOVED,UNLESS OTHERWISE INDICATED ON THE _ ♦ APPROX.80 LF TOP 2"BIT.CONC. 3 } DRAWINGS,SHALL BE DISPOSED OFF SITE IN A LEGAL MANNER. - C-3 FIBER ROLL PAVEMENT AND LAY wl o o ♦ NEW 2"TOP COURSE 6. CONTRACTOR SHALL NOTIFY THE ENGINEER OF OBSTRUCTIONS =I o ENCOUNTERED DURING THE CONSTRUCTION OF PAVEMENTS,UTILITIES ♦ 100-YR FLOOD PLAIN o z o FOUNDATIONS AND PADS. _ f WASHED STONE o �a ♦ � �- (ELEVATION=33) 4 vwi " 7. TO ESTABLISH PROPER GRADES,CONTRACTOR SHALL BE RESPONSIBLE m z FOR INSTALLATION AND MAINTENANCE OF GRADE STAKES. THE ♦ J 1 vS o v0 NUMBER AND LOCATION SHALL BE DETERMINED IN THE FIELD AND I- �� C-3 APPROX.16 LF 0 0 21 LOU APPROVED BY THE ENGINEER. _ -I '.♦♦ FIBER ROLL CRUSHED STONE N o za 8. ALL AREAS OUTSIDE THE LIMITS OF WORK DISTURBED BY _ _ t�♦ _= ,_-' _9- _ PROTECT EXISTING 12 RCP us�� CONTRACTOR'S OPERATIONS SHALL BE REPAIRED AT THE CONTRACTOR'S _ e / SEE _-#�.t/ AND DRAINAGE STRUCTURES Moo.z EXPENSE IN A MANNER APPROVED BY THE ENGINEER. ------- I m 0 9. CONTRACTOR SHALL PROTECT EXISTING FENCES AND GATES UNLESS _ - 1"=10' o N o OTHERWISE SHOWN TO BE REMOVED OR AS APPROVED BY OWNER AND _ sa m 0.. ENGINEER. � 5 0 10 T Ew = 50-FT- UIL_-ZONE _®t 10.CONTRACTOR SHALL CLEAN ALL EXISTING CATCH BASINS WITHIN THE . � '/ a---_ _ °Ea - /� AREAS OF WORK AFTER CONSTRUCTION WORK IS COMPLETE3 Iv) . # _ t _ O R D D f AW I N G to of XX 6_°_?w DESIGNED BY: J.OLCOTT /� PROJECT NO. 0486-108910 fn J.HEIL VD� GREATER LAWRENCE SANITARY DISTRICT FILE NAME: GRPL002.dwg DRAWN BY: U Smith U a n p SHEET CHK'D BY: J.RCCO o wo CROSS CHK'D BY: B.HICKEY RIVERSIDE PUMP STATION IMPROVEMENTS GRAD NG AND DRA NAGE PLAN SHEET N0. 1 3/12 AE MK RECORD DRAWING BASED ON RED LINES BY GREEN INTERNATIONAL AFFILIATES,INC. 75 State Street,Suite 701 C-2 J.OLCOTT w APPROVED BY: Boston,MA 02109 x o D NO DATE DRWN CHKD REMARKS DATE: MAY 2016 Tel:(617)452-6000