Loading...
HomeMy WebLinkAbout260512_1st_HW_SWPeerReview_520GreatPondRoad - - 500 GREAT POND ROAD Horsley W*itten Grou Sustainable V i� ;,l ,� i ' V Vn li a Solutions 112 # r Street,® 'Floor Boston,MA 02109 ' -263- 1 3 horsleyWitten,mimm May 12, 2026 Ms. Jean Enright, Planning Director Planning Department Town of North Andover 120 Main Street North Andover, Massachusetts 01845 Re: Initial Stormwater Peer Review 520 Great Pond Road North Andover, Massachusetts Dear Ms. Enright and Board Members: The Horsley Witten Group, Inc. (HW) is pleased to provide the North Andover Planning Board with this report summarizing our initial review of the Watershed Special Permit Application for the proposed improvements at 520 Great Pond Road in North Andover, MA. The plans were prepared by Merrimack Engineering Services on behalf of the North Andover Country Club (Applicant). The Applicant has noted on the site plan a parcel size of 18.88 acres. The project proposes tree removal within the high-water limits of the lake onsite and parking lot reclamation and rehabilitation within the same footprint of the existing lot. The proposed actions will not change or increase the total impervious area onsite. The stormwater management for the proposed improvements includes installation of permeable pavers at the downhill side of the parking area and cleaning and clearing of an existing catch basin and an existing French drain of debris. It appears that the total land disturbance is approximately 15,551 sf including erosion controls around the site. The lot is located within the Watershed Protection Overlay District and was incorporated in 1897, before October 24,1994. The lot is located within a rural area, and the area of disturbance is less than 1 acre. A portion of the proposed work is within the 25-foot No Disturb Zone and the 50-foot No Build Zone from the edge of a bordering vegetated wetland (BVW) located to the south and west of the existing building. Most of the project area is within the 100-foot Wetland Buffer Zone and the 100-foot Non-Disturbance Buffer Zone. The proposed parking improvements at the rear of the building are approximately 17.5 feet from the BVW. The closest point of any construction activity to the BVW is the erosion control barrier placed approximately 15 feet from wetland flag 6A. The proposed limit of disturbance is less than 25 feet from the wetland resource area. In accordance with §195-4.19 B.(2)(a) of the North Andover Zoning Bylaws, any surface or subsurface discharge of stormwater within the Non-Discharge Buffer Zone is allowed by special permit granted by the North Andover Planning Board. The proposed project is also within the jurisdiction of the North Andover Conservation Commission. Town of North Andover May 12, 2026 Page 2of3 The following documents and plans were reviewed by HW: • Watershed Special Permit Application, 520 Great Pond Road, North Andover, MA, prepared by Merrimack Engineering Services, dated April 29, 2026 (10 pages); • Plan of Land to accompany a Notice of Intent for Tree Removal, 500 Great Pond Road, North Andover, MA, prepared by Merrimack Engineering Services, dated March 12, 2025; and • Site Development Plan, Site Improvements in North Andover, MA, prepared by Merrimack Engineering Services, dated April 29, 2026 (Sheets 1 and 2 of 2). Stormwater Management Design Peer Review In accordance with §195-4.19.B.(4)All construction in the Watershed Protection District shall comply with best management practices for erosion, siltation, and stormwater control in order to preserve the purity of the groundwater and the lake; to maintain the groundwater table; and to maintain the filtration and purification functions of the land. HW has the following comments and recommendations regarding the proposed stormwater management design. 1. The Applicant has submitted Plans and an Application. It does not appear that the application is complete. The Applicant has not provided all the documentation listed under§195-4.20.0 of the Zoning Bylaw. HW recommends that the Applicant review the Watershed Application instructions and provide the supporting memorandum addressing the individual points. 2. The Applicant has included erosion controls on the site details sheet including a 12-inch mulch sock and silt fence. The site plan calls for an erosion control barrier on the south side of the parking area. It is unclear if these are the same item. HW recommends that the Applicant review the plans and revise callouts or details as needed for clarity. 3. The Applicant has provided a Site Plan with erosion controls and a Tree Removal Plan. It is unclear the extent of the disturbed area and where they are in relation to each other on the property. HW recommends that the Applicant provides a limit of work line on the site plan confirming the total area of disturbance and includes erosion controls around the stockpile. 4. The Applicant has proposed tree removal onsite. It is unclear how the tree removal area will be accessed or what the limit of disturbance will be. Furthermore, a temporary construction access for the parking lot area is not shown for the improvements including the proposed stone walls or the permeable pavers. HW recommends that the Applicant provides a detail of the construction access and location where it will be used. HW suggests that the Applicant considers construction matting or other measures to Town of North Andover May 12, 2026 Page 3of3 minimize the tracking of sediment onto the driveway and offsite per§250-25.E. (13) of the North Andover Code. 5. The Applicant has proposed permeable pavers for the rehabilitation of the parking lot area. HW recommends that the Applicant revise the detail shown on the plans to include washed crushed stone for the bedding, intermediate, and base layers of the pavers. 6. The Applicant has noted the existing soil conditions as Hydrologic Soil Group (HSG) C per the test pit completed onsite. HW recommends that the Applicant provide runoff calculations to justify the size of the proposed permeable pavers and the runoff reduction achieved onsite. HW further recommends that the Applicant include the Natural Resources Conservation Service (NRCS) soil maps for the site. 7. HW notes that the Deep Test Results indicate 52 inches of fill material. HW recommends that the Applicant call out removal of the fill beneath the permeable pavers as well as the appropriate soil type to be placed under the permeable pavers to replace any fill removed. 8. The Applicant has provided Erosion and Sedimentation Control elements on the Site Plan. It does not appear there are any notes for stabilization on the plans or in the supplementary information. HW recommends that the Applicant revise the plans as needed to clarify how the site will be stabilized. HW further recommends that the Applicant indicates how the landscaping will be restored at the end of construction. 9. HW notes that the Applicant has proposed a stone wall along the driveway. HW recommends that the Applicant includes the top and bottom wall elevations. HW notes that if the wall is greater than three feet in height it will require a structural engineer stamp. HW recommends providing additional grades on the plans regarding the stone walls. Furthermore, there is an adjacent power pole near the proposed walls. HW recommends that the Applicant call out support of the pole during construction of the proposed walls. Conclusions HW recommends that the Board requires the Applicant to provide a written response to address these comments. We appreciate the opportunity to assist the Town of North Andover with this project review. Please contact Janet Bernardo at 508-833-6600 or at ibernardo(cD-horsleywitten.com if you have any questions regarding these comments. Sincerely, HORSLEY WITTEN GROUP, INC. ^ f n q Irani i Janet Carter Bernardo, PE Principal