HomeMy WebLinkAboutApplication - - 364 JOHNSON STREET tut
PLANNING DEPARTMENT u `
Community&Economic Development Division
Special Permit—Watershed Permit Application
Please type or punt clearly.
1.Petitioner:Gregory&Melissa Buitkus
Petitioner's Address:364 Johnson Street North Andover,01845
Telephone number&email
2.Owners of the Land:Gregory&Melissa Buitkus
Address:364 Johnson Street North Andover,01845
Number of years of ownership:5(purchased 8/30/2019)
3.Year lot was created: 1964
4. Is the lot currently on septic or sewer?sewer
If on sewer,please provide date the sewer connection was
completed:
5. Description of Proposed Project:The proposed project consists of a 376 square foot addition to
the rear of our existing residence,extending over a basement and two stories for a total of 1,128
square feet of additional living space.The addition will include a new entrance on the Abbott Street
side of the lot.As part of the project, the existing rear deck will be extended to connect with the
new structure.The expanded space will include a kitchen, mudroom, and primary suite.Although
we are already permitted for geothermal heating and cooling,we are unable to fully convert from
fossil fuels until this addition is approved and constructed to accommodate the necessary systems
and layout changes.
6.Description of Premises:residential,single family
7.Address of Property Being Affected:364 Johnson Street
Zoning District: R3 Parcel ID:038.0-0015-0000.0
Assessors Map: r Lot#:AS
Registry of Deeds: Hook#: 15979 Page :2
8.Existing Lot:
Lot Area(Sq.Ft): 26,571 (0,61 AC) Building Height:27.9 ft
Street Frontage:240 ft Side Setbacks:35 ft
Front Setback:37 ft Rear Setback:33 ft
Floor Area Ratio:0,087 Lot Coverage:
9.Proposed Lot(if applicable):NIA
Lot Area(Sq.Ft): Building Height:
Page 1 of 2
120 Main Street,Planning Dept,, North Andover, Massachusetts 01845
Phone 978,688,9535 Fax 978,688.9542 Web m northandoverma gov
Street Frontage: Side Setbacks:
Front Setback: Rear Setback:
Floor Area Ratio: Lot Coverage:
10,Required Lot(as required by Zoning Bylaw):
Lot Area(Sq.Ft):25,000 Building Height:35ft(max)
Street Frontage: 125 ft Side Setbacks:20 ft
Front Setback:30 ft Rear Setback:30 ft
Floor Area Ratio:NIA Lot Coverage:NIA
11.Existing Building(if applicable):
Ground Floor(Sq.Ft.):890 of Floors:2+basement
Total Sq.Ft.:2300 Height:27.9 ft
Use:single family, residential Type of Construction:addition
12.Proposed Building:
Ground Floor(Sq.Ft.): 1266 #of Floors:2+basement(same)
Total Sq.Ft,3428 Height:27.9 ft(same)
Use:single family, residential(same) Type of Construction:addition
13.Has there been a previous application for a Special Permit from the Planning Board on these
premises?No If so,when and for what type of construction?NIA
14.Section of Zoning law that S eciai Permit Is Bein t_
Requested � � � Y i g
15.Petitioner and Landowner signature(s):
Every application for a Special Permit shall be made on this form, which is the official form of the
Planning Board. Every application shall be filed with the Town Clerk's office. it shall be the
responsibility of the petitioner to furnish all supporting documentation with this application. The
dated copy of this application received by the Town Clerk or Planning Office does not absolve the
applicant from this responsibility. The petitioner shall be responsible for all expenses for filing and
legal notification. Failure to comply with application requirements, as cited herein and in the
Planning Board Rules and Regulations may result in a dismissal by the Pianning Board of this
application as incomplete.
Petitioner's Signature:
Print or type name here: eMS��
Owner's Signature:
Print or type name here:Melissa uitkus -P Greong ta,
16.Please list title of plans and documents you will be attaching to this application.
A. General Requirements to Be Met for Obtaining a Watershed Special Permit I Zoning Bylaw Section
10.31
B. Certification of No Significant Degradation to Water Quality or Quantity
C. Statement of No Reasonable Alternative Location Outside Buffer Zones
D. Re: Wastewater TreatmentiDisposai System
E. Certification Regarding Nitrogen Loading and Groundwater Protection
F Letter from Homeowners
G. Stormwater Management Report
H. Plot Plan of Land for 364 Johnson Street
Page 2 of 2
120 Main Street, Planning Dept., North Andover, Massachusetts 01845
Phone 978,688,9535 Fax 978,688.9542 Web www.northandoverma Gov
GENERAL REQUIREMENTS TO BE MET FOR OBTAINING A WATERSHED SPECIAL
PERMIT
In accordance with the North Andover Zoning Bylaw—Watershed Protection District
Project Address: 364 Johnson Street North Andover, MA
Applicant: Gregory& Melissa Buitkus
Date: May 25, 2025
General Requirements
1. Encouraging the Most Appropriate Use of Land
This project supports the continued residential use of the property and enhances the livability
and sustainability of the home without altering the neighborhood character. The addition is
designed in proportion to the existing home and surrounding properties, preserving the most
appropriate and consistent use of the land as single-family residential.
2. Preventing Overcrowding of Land
The project maintains compliance with zoning setback and lot coverage requirements. By
building upward instead of expanding extensively outward, the design preserves more open
space and limits disturbance to the land. The proposed development respects the scale of the
site and avoids any appearance or function of overcrowding.
3. Conserving the Value of Land and Buildings
The addition will enhance the functionality and energy efficiency of the residence while
increasing the home's value. This investment contributes positively to surrounding property
values and maintains the overall desirability of the neighborhood. Improvements such as
modernized space and geothermal heating/cooling increase long-term value and resilience.
4. Lessening Congestion of Traffic
There is no change in the number of residents or dwelling units.All construction traffic will be
confined to the site and will not impact public ways. Once complete, the project will not
contribute to increased traffic generation, parking demand, or congestion.
5. Preventing Undue Concentration of Population
This is a single-family home improvement with no additional dwelling units being created.
Household occupancy remains unchanged, ensuring no impact on residential population density
in the neighborhood or surrounding watershed area.
6. Providing Adequate Light and Air
The proposed addition Complies with zoning requirements for height and setbacks, preserving
light and airflow for both the subject property and neighboring homes. The design minimizes any
shadowing effects and maintains the character of the existing built environment.
7. Reducing the Hazards from Fire and Other Dangers
The construction will meet all applicable building and fire codes. Integrating geothermal heating
and cooling helps eliminate reliance on combustible fuels, reducing fire hazards. The project
also preserves significant vegetation and avoids unnecessary clearing, reducing risk of
environmental degradation.
8.Assisting in the Economical Provision of Transportation, Water, Sewerage, Schools,
Parks, and Other Public Facilities
As there is no increase in population or dwelling units, the addition places no added burden on
town services or infrastructure. The home remains on existing utility connections and will not
affect school enrollment or public service usage. The sustainable design aligns with long-term
resource management goals.
9. Controlling the Use of Bodies of Water Including Watercourses
We have intentionally sited the addition to be as far as possible from the wetland boundary,
respecting all applicable setback requirements.To control runoff and protect the nearby
watercourse, roof runoff will be directed into an underground groundwater recharge system.
Erosion controls such as mulch socks will be employed during construction to prevent sediment
transport into sensitive areas.
10. Reducing the Probability of Losses Resulting from Floods
The property is not located within a floodplain. The project's compact vertical design reduces
impervious surface expansion and avoids redirecting stormwater in a way that could cause
flooding. The water recharge system and careful site grading will mitigate any additional
stormwater impact.
11. Preserving and Increasing the Amenities of the Town
The addition is designed to complement the home and neighborhood while enhancing livability
and sustainability. By increasing the functionality and energy performance of the residence, the
project contributes to the long-term aesthetic and environmental quality of the community.
Transitioning the home to geothermal systems further aligns with the town's goals of
environmental stewardship and resilience.
Zoning Bylaw Section 10 31
1. The specific site is an appropriate location for such a use, structure, or condition.
The proposed addition is to a single-family home, which is a by-right use in the R3 zoning
district. The location is within a well-established residential neighborhood with similarly scaled
homes. The addition is sited at the rear of the property and is fully compliant with zoning
setback and dimensional regulations. It is designed to integrate with the existing residence in a
manner that preserves the lot's open space and minimizes land disturbance, particularly given
its proximity to the watershed protection area. No new structures or uses incompatible with the
zoning district are proposed.
2. The use as developed will not adversely affect the neighborhood.
The proposed addition will not change the use of the property or increase residential density. it
is architecturally consistent with surrounding homes and is designed to blend into the
neighborhood. There will be no increase in traffic, noise, or visual disruption. The home will
retain the same number of occupants.Additionally, the project will likely improve the overall
aesthetics and value of the home, thereby positively contributing to the neighborhood character.
3. There will be no nuisance or serious hazard to vehicles or pedestrians.
The proposed construction will not alter any existing driveways, curb cuts, or pedestrian paths.
All construction vehicles will remain on the property and will not obstruct public roads or rights of
way.The new entrance on the Abbott Street side is designed for residential use and will not
increase pedestrian or vehicle traffic. Once completed, the addition will not generate any new
vehicle trips or increase risk to traffic or pedestrian safety.
4.Adequate and appropriate facilities will be provided for the proper operation of the
proposed use.
The addition is being constructed to current building code standards and will be into the home's
existing utilities, including water, sewer, and electric.A geothermal system, already permitted,
will be fully integrated into the homes HVAC system as part of the addition, reducing fossil fuel
use and enhancing efficiency. Stormwater from the addition will be managed on-site via a
ground recharge system, and erosion will be controlled with mulch socks and other best
management practices during construction.
5. The Special Permit Granting Authority shall not grant any special permit unless they
matte a specific finding that the use is in harmony with the general purpose and intent of
this bylaw.
The proposed addition is fully in harmony with the general purpose and intent of the North
Andover Zoning Bylaw. It upholds the R3 district's goal of maintaining low-density, single-family
residential development, while improving the function, safety, and energy efficiency of an
existing home. The design minimizes environmental impact through compact vertical
construction, runoff mitigation, and erosion control.The project demonstrates responsible
stewardship of the land and promotes public health, safety, and welfare, consistent with the
objectives of the Zoning Bylaw and the protections required in the Watershed Protection District.
Statement of No Reasonable Alternative Location Outside Buffer Zones
Project Address: 364 Johnson Street North Andover, MA
Applicant: Gregory & Melissa Buitkus
Zoning District: R-3 Residential/Watershed Protection District
Date: May 25, 2025
In accordance with the requirements of the North Andover zoning Bylaw governing the
Watershed Protection District, the applicant hereby submits the following justification
demonstrating that there is no reasonable alternative location outside the applicable non-
disturbance and/or non-discharge buffer zones for the proposed structure and associated
activities.
Project Summary
The project consists of a 376-square-foot addition to the rear of an existing single-family
residence, totaling approximately 1,128 square feet of additional living space across two stories
and a basement. The addition will contain a kitchen, mudroom, and primary suite, and will
facilitate the integration of a previously permitted geothermal heating and cooling system. The
project includes an extension of the existing rear deck and installation of stormwater recharge
measures.
Justification for Proposal Location Within Buffer Zone
1. Existing Site Configuration and Wetland Proximity
The existing residence is positioned on the right side of the property,while
wetlands are located on the left side. The proposed addition is to the rear of the
house, built away from the wetland area and as far from resource areas as possible
while maintaining required setbacks and efficient access to the existing structure.Any
attempt to relocate the addition elsewhere on the lot—such as to the left side—would
place it closer to the wetlands and within more sensitive buffer zones, increasing
potential environmental impact and contradicting the intent of the Watershed Protection
Bylaw.
2. Buildable Area Constraints&Zoning Compliance
The property is constrained by front, side, and rear yard setback requirements typical of
the R-3 zoning district. The proposed location is the only buildable area that
accommodates the addition without encroaching on required setbacks or requiring
zoning relief. Building in another location would either be infeasible due to a lack of
space or require greater land disturbance in previously undisturbed areas.
3. Integration with Existing Nome Layout and Utilities
The proposed addition aligns directly with the functional layout of the home and existing
utility infrastructure. Relocating the structure would necessitate reconfiguration of living
spaces, additional grading, and potentially significant rerouting of mechanical systems.
This would increase construction impacts and disrupt the current permitted geothermal
system layout.
4. Minimized Disturbance and Improved Environmental Outcomes
The addition is compact and designed vertically to limit impervious surface expansion
and land disturbance. Stormwater from the roof will be managed through on-site
infiltration, and all construction will take place in previously disturbed or maintained
areas. Temporary erosion controls, including mulch socks, will be installed during
construction.
5. Topography and Drainage
The proposed addition is located at a lower elevation than the adjacent wetlands,
which serve as feeders to Lake Cochichewick.As a result, runoff from the proposed
structure cannot physically flow toward the wetlands due to the natural slope of
the land. Relocating the structure upslope,would likely increase runoff exposure to the
resource area.
Given the site's layout, the location of the wetlands on the opposite side of the lot from the
proposed work, the constraints of zoning setbacks, and the need to minimize environmental
impact, there is no reasonable alternative location for the proposed structure and related
activities outside the applicable buffer zones.The current location maximizes protection of
wetland resources, preserves open space, and supports responsible stormwater management
in accordance with the Watershed Protection District regulations.
Respectfully submitted,
Gregory& Melissa Buitkus
(617)-538-9726 1 (978)-766-16 11
C buitkus09fa7amail.com EL-C-0-M
May 25, 2025
CERTIFICATION REGARDING NITROGEN LOADING AND GROUNDWATER
PROTECTION
In accordance with the North Andover Zoning Bylaw®Watershed Protection
District
Project Address: 364 Johnson Street North Andover, MA
Parcel ID: 038.0-0015-0000.0
Applicant: Gregory & Melissa Buitkus
Prepared by: John J. McDonnell, MSCE, PE, PLS
Massachusetts Registration No.: 33601
Date: May 20, 2025
I, John J. McDonnell, a Registered Professional Engineer in the Commonwealth of
Massachusetts, have reviewed the proposed site development for the property located at 364
Johnson Street, North Andover, MA, located within the Watershed Protection District. The
project entails a 376-square-foot building footprint addition (totaling approximately 1,128
square feet over a basement and two stories), which includes a new bedroom and one new
bathroom, but and may increase the number of residents living in the home.
In accordance with the nitrogen-loading requirements under the North Andover Zoning Bylaw
and Watershed Protection District performance standards, I hereby certify the following:
STATEMENT OF NITROGEN LOAD COMPLIANCE
1. No Increase in Occupancy or Septic Flow Load
This Section does not apply the Project site is serviced by the Town of North Andover's
Municipal sewerage system, thus there will be additional Septic Flow.
Although there will be an increase in occupancy resulting from an additional bedroom
which will be part of the addition, No Introduction of New Nitrogen Sources
The project does not involve any commercial, agricultural, or industrial use that would
generate elevated nitrogen loads. There will be no fertilizer-dependent landscaping,
no animal waste storage, and no surface discharge of septic or graywater. The project is
entirely residential in nature, with no change in use or occupancy density.
2. Stormwater Recharge and Erosion Control
All roof runoff from the proposed addition will be conveyed by piping to a subsurface
infiltration/recharge system, which will ensure that on-site recharge with natural
filtration. No stormwater will be directed toward resource areas or neighboring
properties. Mulch socks and erosion controls will be used during construction to
prevent sediment transport and preserve soil stability.
3. Topography and Groundwater Flow Direction
The addition is located on the right side and rear of the property. Wetlands are
located on the left side of the property, uphill from the proposed construction.
Because the elevation of the addition is lower than the adjacent wetlands, any
groundwater recharge from the construction site will not flow toward the wetlands or
Lake Cochichewick, but rather away from them, following the natural slope of the land
and hydraulic gradient.
4. Concentration of Nitrate-Nitrogen Within EPA Limits
Given the elimination of fertilizer inputs, and infiltration-based stormwater handling, the
project will not result in nitrate-nitrogen concentrations in groundwater at or beyond
the downgradient property boundary exceeding the U.S. EPA limit of 10 mg/L.
If modeled under MassDEP assumptions (e.g., 2 Ibs/person/day nitrogen load with
recharge rates typical for residential soil), the anticipated contribution from this project
remains well within permissible thresholds. Since no additional occupants are added,
nitrogen loading remains effectively unchanged from pre-construction conditions.
Conclusion
It is my professional opinion, based on standard engineering practices and current site design,
that the proposed addition will not contribute to nitrogen levels in groundwater in excess of
10 mg/L nitrate-nitrogen at the downgradient property boundary. The project complies with
the nitrogen-loading provisions of the North Andover Watershed Protection District and the
U.S. Environmental Protection Agency's groundwater quality standards.
OF r`
Res ectfull submitted,
g JOHNMcDON
v CIVIL 11
No.41157
John J cDonnell, MSCE, PE, PLS ��Q�sT
Professional Land Surveyor s�ON
MA License No. 33601
2 Cullen Circle Andover, MA 01810
(978)-569-7850
May 20, 2025
CERTIFICATION OF NO SIGNIFICANT DEGRADATION TO WATER QUALITY OR
QUANTITY
In accordance with the North Andover Zoning Bylaw—Watershed protection District
Project Address: 364 Johnson Street North Andover, MA
Parcel ID: 038.0-0015-0000.0
Applicant: Gregory & Melissa Buitkus
Prepared by: John J. McDonnell, PE, PLS
Massachusetts Registration No.: 33601
Date: May 20, 2025
I, John J. McDonnell, a Registered Professional Engineer in the Commonwealth of
Massachusetts, hereby certify that I have reviewed the plans and supporting documents for the
proposed addition at the above-referenced property. The project includes the construction of a
376-square-foot footprint addition (1,128 square feet of living space over two stories plus
basement) to the rear of the existing single-family residence, within the Watershed Protection
District for Lake Cochichewick.
Based on my professional judgment, and subject to the design measures incorporated
into this project, I hereby certify that:
® The proposed Project has been designed to minimize site disturbance and impervious
surface expansion by utilizing vertical construction and maintaining required setbacks
from resource areas.
® The proposed addition is located on a portion of the site that is lower in elevation than
the adjacent wetlands, which act as feeders to Lake Cochichewick. As such, surface
runoff from the addition to the building will not flow toward the wetlands or Lake
Cochichewick due to natural topography—runoff cannot defy gravity.
® Roof runoff from the new addition will be directed into a subsurface infiltration/recharge
system to promote on-site infiltration and prevent direct discharge into any wetland or
water body. The subsurface infiltration/recharge system has been adequately sized for
the current addition.
• Temporary erosion control measures, including mulch socks, will be installed and
maintained during construction to prevent sediment transport from reaching adjacent
wetland areas.
• The project will not alter existing stormwater flow patterns in a way that increases runoff
or flood potential to downstream areas, including Lake Cochichewick.
® No subsurface wastewater disposal systems are proposed or altered as part of this
project.
® The use of geothermal HVAC systems will reduce reliance on fossil fuels and minimize
environmental impacts associated with heating and cooling operations.
Therefore, it is my professional opinion that the proposed project will not result in any
significant degradation of the quality or quantity of water in or entering Lake
Cochichewick.
Respectfully submitted,
or 44
JOHM
WDONNELL
CIVIL Cn
No.41W
John J. McDonnell, MSCE, PE, PLS (?tSTS
Professional Land Surveyor ONAL LNG
MA License No. 33601
2 Cullen Circle Andover, MA 01810
(978)-569-7850
May 20, 2025
RE: WASTEWATER TREATMENT/DISPOSAL SYSTEM
In accordance with the North Andover Zoning Bylaw—Watershed Protection District
Project Address: 364 Johnson Street North Andover, MA
Parcel ID: 038.0-0015-0000.0
Applicant: Gregory &Melissa Buitkus
Date: May 26, 2025
No industrial wastewater treatment or disposal system or any wastewater treatment system of
15,000 gallons per day capacity will be utilized. No DEP file applicable.