HomeMy WebLinkAboutSite Plans - - PREPARED FOR:
verizon%/
118 FLANDERS ROAD
• rTO WESTBOROUGH,MA01581
veri7v.. n
HUDSON
Design -_ --
45 BEECHWOOD DRIVE TEL:(978)557-5553
N.ANDOVER,MA 01845 FAX:(978)336-5586
NORTHANDOV R5MA (ROG RS C NT R)
315 TURNPIKE STREET
NORTH ANDOVER, MA 01845 _v
CD
PROJECT SUMMARY PROJECT SUMMARY SHEET INDEX
SITE NAME NORTH ANDOVER 5 MA SNEOET DESCRIPTION
PROJECT ENGINEER SITE ADDRESS: 315 TURNPIKE STREET
NORTH ANDOVER, MA 01845 T-1 TITLE SHEET CHECKED BY: JX
HUDSON DESIGN GROUP, LLC C-1 PLOT PLAN
45 BEECHWOOD DRIVE APPUCANT: VERIZON WIRELESS A-1 SITE PLAN
NORTH ANDOVER, MA 01845 118 FLANDERS ROAD APPROVED BY: DPH
TEL: 1-(978)-557-5553 WESTBOROUGH, MA 01581 A-2 ELEVATION
FAX: 1-(978)-336-5586 A-3 EQUIPMENT PLAN SUBMITTALS
ZONING DISTRICT: RESIDENTIAL 3 REV. DATE DESCRIPTION BY
MEP ENGINEER ZONING JURISDICTION: TOWN OF NORTH ANDOVER, MA
HUDSON DESIGN GROUP, LLC
45 BEECHWOOD DRIVE LATRUDE: N42° 40' 05.99"
NORTH ANDOVER, MA 01845
TEL:1-(978)-557-5553
FAX:1-(978)-336-5586 LONGITUDE: 1 TUDE: W71° 07' 18.99" 0 JM
1 O8/14/19/ REVISED PER COMMENTS
/19 REVISED PER COMMENTS OS
PARCEL ID: 025.0-001 3-0000.0 0 04/11/19 IFOR ZONING OS
PROPERTY OWNER: MERRIMACK COLLEGE SITE NAME:
315 TURNPIKE STREET NORTH ANDOVER 5
NORTH ANDOVER, MA 01845
MA
® � (ROGERS CENTER)
VICINITY MAP SCALE:N.T.S.
SITE ADDRESS:
DIRECTIONS TO SITE: 315 TURNPIKE STREET
NORTH ANDOVER, MA 01845
HEAD SOUTHWEST TOWARD FLANDERS RD.
TURN RIGHT ONTO FLANDERS RD.CONTINUE ONTO CONNECTOR RD.
TURN RIGHT ONTO RESEARCH DR.TURN LEFT TO MERGE SHEET TITLE
ONTO MA-9 E. MERGE ONTO 1-495 N VIA THE RAMP TO LOWELL.
TAKE EXIT 42A TO MERGE ONTO MA-114 E/SALEM TITLE SHEET
TURNPIKE/WINTHROP AVE TOWARD MIDDLETON. MERGE ONTO MA-114
E/SALEM TURNPIKE/WINTHROP AVE. CONTINUE ONTO MA-114
E/MA-125 S.TURN RIGHT ONTO WALSH WAY.
SHEET NUMBER
T-i
PREPARED FOR:
V-
PARCEL ID: ~ / ~
024.0-0028 /�r ` PARCEL ID: O verizon
PARCEL ID: �O ♦ 1 024.0-0051 N
024.0-0031 PARCEL ID:
O 118 FLANDFRS ROAD
PARCEL ID:
�, 024.0-0054 wesTBOROUTsoRoucH,MA o15s1
D
024.0-0030 ✓ PARCEL I : ♦��O \ PARCEL ID:
PARCEL ID:
' %'� 024.0-0045 ��Q �� /. 047.0-0031 �+
024.0-0029 PARCEL ID: �i 'QQ i, PARCEL ID: PARCEL ID:
024.0 0008 024.0-0073 025.0-0066
v' PARCEL ID:
✓ 047.0-0014
\/ PARCEL ID: H U D S O N
/ ` ♦ 047.0-0015 Design
PARCEL ID: 45/ /
♦ 047.0-001 6 /' \/ / N.AND0 ER,MA 01845 FAX:(978)336
PARCEL ID: 5586
` ♦ \
2.0.51 /
SOURCE:
TOWN OF NORTH ANDOVER, MA&TOWN OF ANDOVER, MA ZONING MAPS
AND GIS ONLINE MAPS (ACCESSED 03-29-2019)
SITE SPECIFIC NOTES:
�� //� ♦�� 1. SITE SURVEY HAS NOT BEEN CONDUCTED BY HUDSON DESIGN GROUP,
•yh ` �\1 � \ LLC FOR THIS PROJECT.ALL SETBACKS SHOWN ON THIS PLAN ARE �
PARCEL ID:
025.0-0035 TAKEN FROM TIP OF PROPOSED ANTENNAS TO PROPERTY LINES AND l
ARE APPROXIMATE. _
2. VERIFY AZIMUTHS W/ RF ENGINEER.
3. PROPERTY LINE INFORMATION IS COMPILED FROM ASSESSORS PLAN ' - U
be PROPOSED �O,L AND RECORD DOCUMENTS AND IS NOT TO BE CONSTRUED AS HAVING =,
I VERIZON 20\� BEEN OBTAINED AS THE RESULT OF A FIELD BOUNDARY SURVEY,AND °
J' WIDE ACCESS \�i� �? IS SUBJECT TO CHANGE AS AN ACCURATE FIELD SURVEY MAY
J — EASEMENT ' 6 DISCLOSE.A FULL BOUNDARY SURVEY WAS NOT PERFORMED. 1 � i
PROPOSED VERIZON
2.0.51A ��'
l PARCEL ID: Q ` 11'-0"X18•-8"LEASE
/ QZ 2� ♦ AREA(205 SQ Fr)WITH ZONES: CHECKED BY: JX
♦ BRICK SCREEN WALL TO
cP cry MATCH EXISTING R-3 RESIDENTIAL 3 APPROVED BY: DPH
`♦ PARCEL ID: R-4 RESIDENTIAL 4
♦ 025.0-0067 R-5 RESIDENTIAL 5 SUBMITTALS
B-2 BUSINESS 2 REV. DATE DESCRIPTION BY
♦ B-4 BUSINESS 4
/ —
SRB SINGLE RESIDENCE B
PARCEL ID:025.0 0013 1
MERRIMACKF COLLEGE C' PARCEL ID: LEGEND:
315 TURNPIKE STREET 025.0-0012
SUBJECT PROPERTY LINE 2 09/25/19 REVISED PER COMMENTS dM
® NORTH ANDOVER,MA 01845
AREA=56.95 ACRES 1 08/14/19 REVISED PER COMMENTS OS
PARCEL ID: J � __ .>�Q —— ABUTTING PROPERTY LINE o 04/11/19 FOR ZONING os
ACCESS DRIVE/EASEMENT SITE NAME:
� PARCEL ID:
I ZONING DISTRICT BOUNDARY LINE NORTH ANDOVER 5
025.0-0021 PARCEL ID. I I MA
\ ` 025.0-0014 El EXISTING BUILDING (ROGERS CENTER)
� �I
\ I?'-3XXX—XXX—XXX PARCEL ID
I SITE ADDRESS:
Z�N PARCEL ID: STREET315 TURNPIKE NORTH ANDOVER, MAO 845
R"5 1 I 025.0-0079 ZONING INFORMATION:
►� I JURISDICTION: TOWN OF NORTH ANDOVER, MA
SHEET TITLE
PARCEL ID: I���
ZONING DISTRICT TYPE: RESIDENTIAL 3
�\ �\ 025.0-0016 �_- ' DIMENSION REQUIREMENTS: REQUIRED PROPOSED PLOT PLAN
1` FRONT YARD SETBACK: 35' 359't
'�\ I? SIDE YARD SETBACK: 30' 124'f& 1731'f
z GRAPHIC SCALE REAR YARD SETBACK: 20' 471'f SHEET NUMBER
N PLOT PLAN 1 0 100 200 400 600 FEET MAXIMUM BUILDING HEIGHT: 30' N/A
22x34 SCALE: 1"=200' C-1
1 1 x17 SCALE: 1"=400'
I c-
(ALL MEASUREMENTS ARE IN FEET t UNLESS OTHERWISE NOTED)
NOTE: APPROXIMATE LATITUDE: N42° 40' 05.99" PROPOSED VERIZON 13'-0"X13'-O" PREPARED FOR:
AN ANALYSIS OF THE CAPACITY OF THE COORDINATES: LONGITUDE: W71° 07' 18.99" NON-PENETRATING BALLAST MOUNT
EXISTING STRUCTURE TO SUPPORT THE ON ROOF(TYP.OF 1 PER SECTOR, I-1
PROPOSED LOADING HAS NOT BEEN COMPLETED TOTAL OF 4)
BY HUDSON DESIGN GROUP, LLC. DRAWINGS
ARE SUBJECT TO CHANGE PENDING OUTCOME " 0 verizon
OF A STRUCTURAL ANALYSIS. PROPOSED 30 O.D.FIBERGLASS STACK N
(PAINT TO MATCH EXISTING STACK ON THE
ADJACENT BUILDING) 118 O TANDERS ROAD
WE
WESTBOROUGH,MA 01581
PROPOSED VERIZON JUNCTION BOX ON FBI
PROPOSED MOUNT
SIDEWALK (TYP.OF 1 PER SECTOR,TOTAL OF 4)
PROPOSED VERIZON PANEL ANTENNA
INSIDE PROPOSED FIBERGLASS STACK
MP.OF 4 PER SECTOR,TOTAL OF 16) H U D S O N
PROPOSED VERIZON RRH ON PROPOSED MOUNT Design Group LLC
DELTA (TYP,OF 4 PER SECTOR,TOTAL OF 16)
SECTOR 45 BEECHWOOD DRIVE TEL(978)557-5553
330"
PARKING LOT N.ANDOVER,MA 01845 FAX:(978)336-5586
EXISTING ROOF
ACCESS HATCH
+I
� 48'-6"t 1
=I A-2
CD ff EXISTING BUILDING
ALPHA
N SECTOR
GAMMA 18'-6"� 50" PROPOSED VERIZON GPS UNIT
SECTOR EXISTING HATCH ON PROPOSED CABLE HOOD
2350 (TYP.) EXISTING ELECTRICAL&TELCO
ROOM OF FIRST FLOOR
EXISTING HVAC UNIT INSIDE
❑ BRICK SCREEN WALL ON GRADE t l
/
EXISTING BRICK SCREEN WALL
-H PROPOSED VERIZON
A PROPOSED VERIZON "
" CABLE TRAY ALONG 11-0"X18-8 LEASE AREA `J
42-6 f o ROOF 1 (205 SQ FT)WITH BRICK L
L J SCREEN WALL TO MATCH EXISTING
\ \ CHECKED BY: JX
BETA ----L --_1 Li \
SECTOR \X APPROVED BY: DPH
1450 PROPOSED UTILITIES FROM f ---- \ �� SUBMITTALS
EXISTING ELECTRICAL ROOM TO ,
PROPOSED EQUIPMENT AREA PROPOSED VERIZON EQUIPMENT ON 1 REV. DATE DESCRIPTION BY
PROPOSED VERIZON CABLE PROPOSED 4'X11'CONCRETE PAD A-3
INSIDE EMT TO RUN INSIDE I I
BUILDING FROM EQUIPMENT I I
AREA TO PROPOSED CABLE I I
HOOD ON ROOF PROPOSED NEW LOCATION FOR
EXISTING WATER GATE RECESSED
EXISTING WALL VENTILATION IN BUILDING FACADE I 2 09/25/19 REVISED PER COMMENTS JM
I 1 08/14/19 REVISED PER COMMENTS 0S
EXISTING DRAIN (TYP.) SIDEWALK I I 0 04/11/19 FOR ZONING OS
I I
SITE NAME:
NORTH ANDOVER 5
MA
\� (ROGERS CENTER)
\ SITE ADDRESS:
WALSH WAY
PROPOSED VERIZON 20' \� 315 TURNPIKE STREET
WIDE ACCESS EASEMENT NORTH ANDOVER, MA 01845
SHEET TITLE
SITE PLAN
o� GRAPHIC SCALE
,z_:J�� SITE PLAN 1 0 8 16 32 48 FEET SHEEP NUMBER
+ �� 22x34 SCALE: 1/16"=1 A-1 A-i
11x17 SCALE: 1/32"=1'-0"
NOTE: PREPARED FOR:
AN ANALYSIS OF THE CAPACITY OF THE PROPOSED ANTENNA INFORMATION
EXISTING STRUCTURE TO SUPPORT THE I�1
PROPOSED LOADING HAS NOT BEEN COMPLETED
BY HUDSON DESIGN GROUP, LLC. DRAWINGS SECTOR STATUS AZIMUTH CABLE LENGTH •
ARE SUBJECT TO CHANGE PENDING OUTCOME c verizon
OF A STRUCTURAL ANALYSIS. ALPHA PROPOSED 50` 230' �Nyy
BETA PROPOSED 145° 270' 04 118 FLANDERS ROAD
O GAMMA PROPOSED 235' 330' WESTBOROUGH,MA01581
DELTA PROPOSED 330° 300,
NOTE:CABLE LENGTH=EXACT LENGTH PLUS 25'.
CONTRACTOR TO VERIFY CABLE LENGTH PRIOR TO ORDERING.
HUDSON
Design Group--
45 BEECHWOOD DRIVE TEL:(978)557-5553
N.ANDOVER,MA 01845 FAX:(978(336-5586
PROPOSED 30"O.D.FIBERGLASS STACK
(PAINT TO MATCH EXISTING STACK ON THE
ADJACENT BUILDING) PROPOSED VERIZON RRH ON PROPOSED MOUNT
PROPOSED VERIZON PANEL ANTENNA (TYP.OF 4 PER SECTOR,TOTAL OF 16)
INSIDE PROPOSED FIBERGLASS STACK PROPOSED VERIZON 13'-0"X13'-0"
(TYP.OF 4 PER SECTOR,TOTAL OF 16) NON-PENETRATING BALLAST MOUNT ON ROOF
PROPOSED VERIZON JUNCTION BOX ON (TYP.OF 1 PER SECTOR,TOTAL OF 4)
PROPOSED MOUNT
TOP OF PROPOSED VERIZON FIBERGLASS (TYP.OF 1 PER SECTOR,TOTAL OF 4)
STACK HIGHEST APPURTENANCEiF
ELEV.= 58'-0"f (AGL) g`
300'-0"f(AMSL) PROPOSED VERIZON GPS UNIT
ON PROPOSED CABLE HOOD _ D
PROPOSED VERIZON CABLE INSIDE IIII III I I I III /lin
-H
OF PROPOSED_VERIZON ANTENNAS _ II II II EXISTING BUILDING
EMT TO RUN INSIDE BUILDINGoELEV.= 54'-0"f (AGL) FROM EQUIPMENT AREA TO IIII IIII I IIII296'-0"f(AMSL) PROPOSED CABLE HOOD ON ROOF II L Llf� o
TOP OF EXISTING ROOF
ELEV. = 48'-0"± (AGL)
290'-O"± (AMSL)
t
CHECKED BY: JX
-H EXISTING WALL VENTILATION I APPROVED BY: DPH
c
o
I
00 -H TOP OF EXISTING LOWER ROOF SUBMITTALS
ELEV. = 27'-8"± (AGL)
0 269'-8"± (AMSL) I REV. DATE DESCRIPTION BY
co
I
r —— 2 09/25/19 REVISED PER COMMENTS JM
1
1 08/14/19 REVISED PER COMMENTS OS
0 04/11/19 FOR ZONING OS
SITE NAME:
NORTH ANDOVER 5
0 GRADE MA
ELEV. = 0'-O"± (AGL) (ROGERS CENTER)
242'-0"± (AMSL)
PROPOSED NEW LOCATION PROPOSED VERIZON 11'-0"X18'-8" EXISTING BRICK
FOR EXISTING WATER LEASE AREA(205 SQ FT)WITH SCREEN WALL SITE ADDRESS:
GATE RECESSED IN BRICK SCREEN WALL TO MATCH 315 TURNPIKE STREET
BUILDING FACADE EXISTING NORTH ANDOVER, MA 01845
GRAPHIC SCALE SHEET TITLE
ELEVATION 1 0 4 8 16 24 FEET
22x34 SCALE: 1/8"=1'-0" A-2 ELEVATION
11x17 SCALE: 1/16"=V-0"
SHEET NUMBER
A-2
PREPARED FOR:
verizon
-vl
118 FLANDERS ROAD
OWESTBOROUGH,MA01581
I �
I 11'-0"f
f " I f " f "
2-8 f 5-0 t 3-4 t
PROPOSED 5'WIDE H U D S O N
ACCESS GATE -   =
W/COMBO LOCK 45 BEECHWOOD DRIVE TEL:(978)557-5553
PAINTED BROWN TO N.ANDOVER,MA 01845 FAX:(978(336-5586
MATCH BRICK
COLOR
_-__________
I
PROPOSED VERIZON
UTILITIES FROM
EXISTING ELECTRICAL
ROOM TO PROPOSED EXISTING PARKING SIGN
EQUIPMENT AREA O TO BE RELOCATED -H
3"CRUSHEDao
STONE OVER I
FOUNDATION NOTES&CONCRETE SPECIFICATIONS:
MIRAFI FILTER 04 1. FOUNDATION AREA SHALL BE EXCAVATED TO THE DEPTH AND DIMENSIONS SHOWN ON
a FABRIC THE PLANS. EXISTING LEDGE AND ALL OTHER EXISTING UNSUITABLE MATERIAL SHALL
a BE REMOVED AND LEGALLY DISPOSED OF OFF-SITE.THE SUBGRADE SHALL BE
PROPOSED(2)4"DIA. ROLLED WITH A 1-TON,VIBRATORY,WALK-BEHIND ROLLER AT A SPEED OF LESS1 L t
----- PVC CONDUITS THROUGH CONCRETE PAD THAN 2 FPS, 6 PASSES MINIMUM,TO PROVIDE UNYIELDING SURFACE.
PROPOSED PPC I I I I 2. UNDERCUT SOFT OR "WEAVING"AREAS A MINIMUM OF 12 INCHES DEEP. BACKFILL �
WITH CAM-LOK I I PROPOSED TRANSFORMER UNDERCUT AREA WITH FILL MEETING THE SPECIFICATIONS OF STRUCTURAL FILL.
MOUNTED ON
EXISTING WALL I 3. CONCRETE TO HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH (f'c)=4000 psi.
CONCRETE TO BE AIR ENTRAINED, DESIRED AIR CONTENT TO BE 6% (PLUS OR MINUS
+I
I I I PROPOSED 4'X11'CONCRETE'06 \
I I I I I PAD 2%) 4J f 1
EXISTING WATER I 4. REINFORCING BAR TO BE ASTM A615 GRADE 60.
GATE RECESSED I ILr.L
IN BUILDING 5. WELDED WIRE FABRIC TO CONFORM TO THE REQUIREMENTS OF ASTM A185.WIRES
FACADE TO RELOCATED BE I I ` FOR FABRIC TO CONFORM TO THE REQUIREMENTS OF ASTM A82.
L I I EQUIPMENT PROPOSED LED CHECKED BY: JX
- CABINET FLOODLIGHT ON 60 6. COORDINATE WITH MANUFACTURER OF PREFABRICATED SHELTER FOR LOCATION OF
I MIN TIMER SWITCH ATTACHMENTS TO BASE SLAB.
(TYP.OF 2) APPROVED BY: DPH
Lo1 7. ALL REINFORCING TO HAVE MINIMUM CONCRETE COVER PER ACI SPECIFICATIONS.
EXISTING BUILDING
1 I 8. ALL CONCRETE MATERIALS AND WORKMANSHIP SHALL CONFORM TO LATEST EDITION SUBMITTALS
I OF ACI 318 AND APPLICABLE STATE BUILDING CODE.
PROPOSED VERIZON REV. DATE DESCRIPTION er
CABLE TO RUN INSIDE I CABINET PROPOSED VERIZON 20' SEE PLAN
BUILDING FROM WIDE ACCESS EASEMENT (2)4"DIA.PVC CONDUITS
EQUIPMENT AREA TO 1
PROPOSED CABLE I THROUGH CONCRETE PAD
HOOD ON ROOF I I I I I #4 BARS® 10"O.C./E.W. 1"CHAMFER
PROPOSED VERIZON
CABINETS CENTERED I .=. = 2 09/25/19 REVISED PER COMMENTS JM
BETWEEN POSTS o �: ;= a a—
1 08/14/19 REVISED PER COMMENTS OS
I . � �
114
=III=III=11I—II.. e a a< a Tfi= 0 04/11/19 FOR ZONING OS
—I
SITE NAME:
I 2"DOW STYROFOAM HIGHLOAD NORTH ANDOVER 5
I PROPOSED NEW LOCATION PROPOSED VERIZON 60 EXTRUDED POLYSTYRENE MA
FOR EXISTING WATER 11'-0"X18'-8"LEASE AREA 12"MIN.COMPACTED (ROGERS CENTER)
I GATE RECESSED IN (205 SQ FT)WITH BRICK SCREEN FROST-FREE GRAVEL FILL
I BUILDING FACADE WALL TO MATCH EXISTING
I CONCRETE PAD DETAIL 2 SITE ADDRESS:
'I 22x34 SCALE: N.T.S A-3 315 TURNPIKE STREET
NORTH ANDOVER, MA 01845
SHEET TITLE
EQUIPMENT PLAN
70,
GRAPHIC SCALE
EQUIPMENT PLAN 1 0 1 2 4 6 FEET
/�J�� 22x34 SCALE: 1/2"=V-0" A-3 SHEET NUMBER
*// �p 1 1 x 17 SCALE: 1/4"=1'-0"
A-3