Loading...
HomeMy WebLinkAboutPASS - Title V Inspection Report - 89 CHRISTIAN WAY 8/21/2026 Commonwealth of Massachusetts ,x .1 V Title 5 Official M Subsurface Sewage Disposal System Form - Not for Voluntary Assessments a 76 G RANVI LLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER . MA 01 845 SEPTEMBER 2 2026 required for every 1 page. City/Town State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:when A. Inspector Information filling out forms on the computer, Todd James Bateson use only the tab key to move your Name of Inspector cursor-do not Bateson Enterprises Inc. use the return key. Company Name 1 1 1 Argilla Road tab Company Address Andover MA 01810 p CitylTown State Zip Code ' re�r�n 978-475-4786 SI-16 Telephone Number License Number 13. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined that the system: . ® Passes 2. ❑ Conditionally Passes 3. El Needs Further Evaluation by the Local Approving Authority 4. El Fails SEPTEMBER 2, 2026 Ins ctor's Sign ture Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 101000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposai System-Page 1 of 18 Commonwealth of Massachusetts wTitle 5 Official Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments a N h 9 I 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2026 required for every page, City/Town State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: 2) System Conditionally Passes: ❑ one or more system components as described in the "Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass, Check the box for"yes", "no" or"not determined" (Y, N, ND) for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. * A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 18 Commonwealth of Massachusetts xc' I r ia Inspect"oForinvp Title 5 'Off i1� m Ir �y 10 Subsurface Sewage Disposal System Form Not for Voluntary Assessments jrr{ 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner .Owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2026 required for every page, City/Town State Zip Code Date of Inspection C. Inspection Summary (cunt.) 2) System Conditionally Passes (cant.): El Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. El Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced El Y ❑ N El ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N Ej ND (Explain below): [-1 distribution box is leveled or replaced ❑ Y El N 0 ND (Explain below): El The system required pumping more than 4 times a year due to broken or obstructed pipes). The system will pass inspection if(with approval of the Board of Health): Ej broken pipe(s) are replaced ❑ Y El N Ej ND (Explain below): El obstruction is removed OY FIN ❑ ND (Explain below): 3) Further Evaluation is Required by the Board of Health: El Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15,303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: t5insp.d6c-rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 18 , Commonwealth of Massachusetts f i i i ■ . pt, Form Ire a Subsurface Sewage Disposal System Form - Not for Voluntary Assessments JJr; Y r 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner Owner's Name information is NORTH AN DOVE R MA 01845 S E PTEM B E R 2, 2026 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) {❑ Cesspool or privy is within 50 feet of a surface water El Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Dater Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. [:1 The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well'". Method used to determine distance: * This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate "Yes" or"No" to each of the following for all inspections: Yes No Backup of sewage into facility or system component due to overloaded or ® clogged SAS or cesspool gg p F-❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc-rev.712612018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 4 of 18 Commonwealth of Massachusetts rTitle 5 Offici"al Inspection ors Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 76 GRANVILLE LANE Property Address JOANNE HENNINOSEN Owner owner's Name information is NORTH AN DOVE R MA 01845 S EPTE M B ER 2, 2026 required for every page. City/Town State Zip Code Date of Inspection C. inspection Summary (coat.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool El N Liquid depth in cesspool is less than 5" below invert or-available volume is less than %day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipes). Number of times pumped: El ® Any portion of the SAS, cesspool or privy is below high ground water elevation. 1:1 z Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. E] z Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. 1:1 z Any portion of a cesspool or privy is within 50 feet of a private water supply well. 1:1 z Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis, [This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of.ammonia nitrogen and nitrate nitrogen is equal_to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] El N The system is a cesspool serving a facility with a design flow of 2000 gpd- 101000 gpd. �❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems; To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no" to each of the following, in addition to the questions in Section C.4. Yes No ❑ [] the system is within 400 feet of a surface drinking water supply [❑ [❑ the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area— IWPA) or a mapped Zone 11 of a public water supply well t5insp.doc rev.7/26/2018 Title 5 Official Inspection Farm:Subsurface Sewage Disposal System-Page 5 of 18 Commonwealth of Massachusetts YTitle 5 Official Form t 4 Subsurface Sewage Disposal System Form - Not for Voluntary Assessments Lb ,�► 76 ORANVILLE LANE Property Address JOANNE HENNINOSEN Owner owner's Name information is required for every NORTH ANDOVER MA 01845 SEPTEMBER 2, 2026 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered "yes" to any question in Section C.5 the system is considered a significant threat, or answered "yes" to any question in Section C.4 above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate "yes" or"no" for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? E El Were as built plans of the system obtained and examined? (If they were not available note as NIA) Z ❑ Was the facility or dwelling inspected for signs of sewage back up? Z 1-1 Was the site inspected for signs of break out? E El Were all system components, excluding the SAS, located on site? E El Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? E ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health, ® El Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5) t5insp.doc-rev.7/26/2018 Title 5 Official inspection Form.Subsurface Sewage Disposal System-Page 6 of 18 Commonwealth of Massachusetts �t Title5 Official Inspect"ion rill IM ej Subsurface Sewage Disposal System Form Not for Voluntary Assessments g p Y rY 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner Owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2026 required for every page. City/Town State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms (design): 3 Number of bedrooms (actual): 3 � } DESIGN flow based on 310 CMR 15.203 for example: 110 d x#of bedrooms): 450 GPD � p gp } Description: Number of current residents. 2 Does residence have a garbage grinder? El Yes ® No Does residence have a water treatment unit? El Yes N No If yes, discharges to: Is laundry on a separate sewage system? (Include laundry system inspection El Yes ® No information in this report.) Laundry system inspected? ® Yes ❑ No Seasonal use? El Yes E No Water meter readings, if available last 2 ears usage d : ATTACHED g � Y g �gp }} Detail: Sump pump? El Yes N No Last date of occu anc : CURRENT y Date t5insp,doc-rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 18 Commonwealth of Massachusetts Title 5 Offic'ial For I,7 7 Subsurface Sewage Disposal System Form Not for Voluntary Assessments q 7r14tiy,4� 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER MA 01 845 SEPTEMBER 2, 2026 required for every page, City/Town State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/industrial Flow Conditions: Type of Establishment: Design flow (based on 310 CMR 5.203): Gallons per day(gpd) Basis of design flow (seatslpersonslsq.ft., etc.): Grease trap present? El Yes ❑ No Water treatment unit present? El Yes ❑ No If yes, discharges to: Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? El Yes [:1 No Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: BATESON ENTERPRISES INC SEPTEMBER 2024 Was system pumped as part of the inspection? El Yes E No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: t5insp.doc-rev.7/25/2018 Title 5 Official inspection Form:Subsurface Sewage Disposal System-Page 8 of 18 Commonwealth of Massachusetts r,,� Title Offic"ial ection w �R Y Subsurface Sewage Disposal System Form - Not for Voluntary Assessments h 75 GRANVI LLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2025 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: E Septic tank, distribution box, soil absorption system El Single cesspool ❑ overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract (to be obtained from system owner) and a copy of latest inspection of the IIA system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ other(describe): Approximate age of all components, date installed (if known) and source of information: 44 YEAR OLD SYSTEM, LEACH PITS 1982, TANK REPLACED 2006, D--BOX REPLACED 2011 Were sewage odors detected when arriving at the site? ❑] Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: 3' feet Material of construction: cast iron E 40 PVC CAST IRON THROUGH WALL El other explain}: PVC IN CELLAR Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): JOINTS AND VENTING OK NO EVIDENCE OF LEAFAGE t5insp,doc-rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 18 111`L,. Commonwealth of Massachusetts Forr�t �. luTitleOfficial T 4� Subsurface Sewage Disposal System Form w Not for Voluntary Assessments ~iersy��'b. 75 G RANVI LLE LANE Property Address JOANNE HENNINGSEN Owner Owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2026 required for every page. CitylTown State Zip Code Date of Inspection D. System Information (cont.) 5. Septic Tank (locate on site plan): Depth below grade: 21 feet Material of construction: El concrete El metal El fiberglass E polyethylene El other (explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) El Yes Ej No Dimensions: 0' x 5' X 4' Sludge depth: 4" Distance from top of sludge to bottom of outlet tee or baffle 34" 211 Scum thickness 511 Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle 12" How were dimensions determined? SLUDGE JUDGE TAPE MEASURE Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): RECOMMEND PUMPING OLDER SYSTEMS YEARLY PLASTIC INLET AND OUTLET TEES OK PLASTIC TANK OK a LIQUID LEVELS GOOD NO EVIDENCE OF LEAKAGE INLET AND OUTLET COVERS 8" DEEP SPIN OFF COVERS t5insp,doc►rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 18 Commonwealth of Massachusetts x 4Title 5, Official Forrn 'r Subsurface Sewage Disposal System Form Not for Voluntary Assessments n 75 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2025 required for every page, City/Town State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: El concrete n metal El fiberglass El polyethylene El other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: E-1 concrete El metal El fiberglass ❑ polyethylene El other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t5insp.doc rev.7/2012018 Title 5 official inspection Form:Subsurface Sewage Disposal System-Page 11 of 18 Commonwealth of Massachusetts Y ' uTitle 5 Off i cia Inspection ors F Subsurface Sewage Disposal System Form - Not for Voluntary Assessments N 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH AN DOVE R MA 01845 S E PTEM B E R 2, 2026 required for every page. City/Town State Zip code Date of Inspection D. System information (cont,) 8. Tight or Holding Tank (coat.) Alarm present: ❑ Yes El No Alarm level: Alarm in working order: El Yes El No Date of last pumping: Date Comments (condition of alarm and float switches, etc.); *Attach copy of current pumping contract (required). Is copy attached? El Yes [:1 No 9. Distribution Box (if present must be opened) (locate on site plan): q Depth of liquid level above outlet invert 0 p Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): D--BOX 1S LEVEL DISTRIBUTION IS EQUAL LIGHT EVIDENCE OF SOLIDS CARRYOVER NO EVIDENCE OF LEAKAGE 3 t5insp.doc rev,7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 18 Commonwealth of Massachusetts Title 5 Offic'ial Inspection Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments N 76 GRANVI LLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2026 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cant.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes El Noy` Alarms in working order: D Yes [-1 No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): ' If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: z leachingits number: 2 p El leaching chambers number: El leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: El overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp.doc•rev.7/26/2018 Tine 5 official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 18 Commonwealth of Massachusetts �Y p Title 5 isial Inspection Form �y Subsurface Sewage Disposal System Form - Not for Voluntary Assessments h r �n �INk 76 GRANVILLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDOVER MA 61845 SEPTEMBER 2, 2026 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): SOIL AND VEGETATION OK NO SIGN OF HYDRAULIC FAILURE OR PONDING RAN CAMERA FROM D-BOX TO PITS PITS WORKING PROPERLY 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth --top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow El Yes No Comments (note condition of soil, signs of hydraulic failures level of ponding, condition of vegetation, etc.): t5insp,doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 18 Commonwealth of Massachusetts x 1 Title 5 Offic"ial Form IleSubsurface Sewage Disposal System Form Not for Voluntary Assessments 7 � T f� 76 GRANVILLE LANE Property Address JOANNE HENNINOSEN Owner Owner's Name information is NORTH ANDOVER MA 0 845 SEPTEMBER 2, 2026 required for every page, City/Town State Zip Code Date of Inspection D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc•rev.7/26/2018 Title 5 official Inspection Form:subsurface Sewage Disposal System•Page 15 of 18 Commonwealth of Massachusetts FA � Form f S Subsurface Sewage Disposal Systems Forms Not for Voluntary Assessments 75 ORANVI LLE LANE Property Address JOANNE HENNINOSEN Owner owner's Name information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 2g25 required for every page, City/Town State Zip Code Date of Inspection D. System Information (cont,) 14, Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building, Check one of the boxes below: Z hand-sketch in the area below ❑ drawing attached separately n:. r Vf h- _a f r ; (I, W. c.r S+• (0 ek4 e. . r t OK 1,C4 10 60'] S t5insp.doc►rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System Page 16 of 18 Commonwealth of Massachusetts Title 5 Official Fors �> Subsurface Sewage Disposal System Form Not for Voluntary Assessments 75 GRANVI LLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name , information is NORTH ANDOVER MA 01845 SEPTEMBER 2, 202E required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont) 15. Site Exam: ® Check Slope ® Surface water ® Check cellar El Shallow wells Estimated depth to high ground water: feet Please indicate all methods used to determine the high ground water elevation: ® obtained from system design plans on record If checked date of design plan reviewed: J U N E 1982 ' p Date ❑ observed site (abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health - explain: PLANS ON FILE El Checked with local excavators, installers - (attach documentation) ❑ Accessed USGS database -explain: You must describe how you established the high ground water elevation: DESIGN PLAN Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5insp.doc-rev.7/26/2018 Title 5 official Inspection Farm:Subsurface Sewage Disposal System-Page 17 of 18 Commonwealth of Massachusetts �Yu Title 5 Offi iaInspect' nForm . W a in Subsurface Sewage Disposal System Form Not for Voluntary Assessments � p v v 76 G RANVI LLE LANE Property Address JOANNE HENNINGSEN Owner owner's Name information is NORTH ANDGVER MA 61 845 SEPTEMBER 2, 2626 required for every page City/Town State Zip Code Date of inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked C. Inspection Summary: 11 21 3, or 5 completed as appropriate 4 (Failure Criteria) and 6 (Checklist) completed ® D. System Information: For 8: Tight/Holding Tank— Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included t5insp.doc•rev.7/26/2018 Title 5 Official inspection Form.Subsurface Sewage Disposal System►Page 18 of 18 Summary Record Card generated on 8/31/2026 10:3611 AM by Nancy Viens Page 1 Town of North Andover Tax Map # 210-106.C-0070-0000x0 Parcel Id 17705 76 GRANVILLE LANE JQANNE HENNINGSEN 75 GRANVILLE LANE NORTH ANDOVER MA 01845 Class 101 Single Family Property Type 1 Residential Size Total 1.11 Acres FY 2026 UB Mailing Index i mrmnin rri.�r.nrw Name/Address Type Loan Number Activelinact, From Until JOANNE HENNINGSEN Owner Active 76 GRANVILLE LANE NORTH ANDOVER MA 01845 MELAKU,MAKONNEN Previous Customer Inactive 5/21/2015 103 BLUE MEADOW LANE S ICKLERVILLE,NJ 08081 TOM NCLETTE Previous Customer I1)actiVe 9/7/2018 76 GRANVILLE LANE NORTH ANDOVER MA 01845 UB Account Taint. Account No Cycle Occupant Name Act!vellnactive Bldg Id.17395,0-76 GRANVILLE LANE Last Billing Date 7/1/2026 3170065 03 Cycle 03 Active UB Services Maint, Account No,3170065 Service Cade Rate Charge Multiplier/Users MISCFEE ADMIN FEE 0.63 518 7.82 11 wTR WATER 01 ALL METER SIZE 72.20 11 UB Meter Maintenance Account No.3170065 Serial No Status Location Brand Type Sine YTD Cons 36433711 a Active ERT HH b Badger w dilater 0.625 0.625 416 Date Reading Code Consumption Posted Date Variance 6/24/2026 1324 m Manual estimate 19 7/10/2026 M4% 3/10/2026 1305 a Actual 18 4/14/2026 W 19% 12/412025 1287 a Actual 20 1/12/2026 0% 9/9/2025 1267 a Actual 22 10/10/2025 17% 616/2025 1245 a Actual 18 7/9/2025 -10% 317/2025 1227 a Actual 20 4/16/2025 -9% 12/612024 1207 a Actual 22 1/14/2025 1% 9/6/2024 1185 a Actual 21 10/812024 13% 6/10/2024 1164 a Actual 20 7/22/2024 37% 317/2024 1144 a Actual 14 4/16/2024 -1% 12/7/2023 1130 a Actual 13 1/15/2024 2% 9/14/2023 1117 a Actual 15 10/13/2023 1 aka 617i2023 1102 a Actual 14 7/14/2023 23% 3/6/2023 1088 a Actual 11 4/12/2023 9% 12/6/2022 1077 a Actual 10 1/16/2023 -30% 9/812022 1067 a Actual 15 10/18/2022 -10% 6/7/2022 1052 a Actual 17 7/18/2022 4% 3/412022 1035 a Actual 15 4/13/2022 -17% 12l712021 1020 a Actual 19 1/17/2022 -24% 9/712021 1001 a Actual 26 10/15/2021 9% 6/4/2021 975 a Actual 23 7/27/2021 -1% 3/412021 952 a Actual 22 4/21/2021 8%