Loading...
HomeMy WebLinkAboutContract #: 2020 - From: 09-28-2026 To: 09-30-2028 - Woodard and Curran - DPW CONTRACT NO. VENDOR NO, _.......4779 CONTRACT FOR ENGINEERING SERVICES WITH THE TOWN OF NORTH ANDOVER This CONTRACT made and entered into on,_day of October 2026, by and between Woodard & Curran, Inc a Massachusetts corporation with a usual place of business at 12 Mountfort Street, Portland, ME, 04101, "ENGINEER" and the Town of North Andover (the "TOWN") a municipal TOWN duly established by law and located at 120 Main Street, North Andover, Essex County, in the Commonwealth of Massachusetts. WHEREAS,the TOWN sought a proposal for professional Engineering services for "SCADA Server Upgrade, Remote Access,and Equipment." WHEREAS, the ENGINEER represents that it is duly qualified in this field, and has agreed to perform such services for the TOWN. NOW,THEREFORE, IT IS AGREED by and between the parties as follows. -1- The ENGINEER will provide "SCADA Server Upgrade, Remote Access, and Equipment" as requested by the TOWN. T h i s assignment is subject to the written scope of work and budget (see AttadvTient A)on a Purchase Order basis,with fees to be paid in accordance with Woodard& Curran,Inc. billing rates (See Attachment B). This Contract will commence upon execution and terminate on September 30, 2028. Time is of the essence for this Contract. Any extensions of time must be in writing and are at the sole discretion of the TOWN. -2- The Priced Proposal,all required Certifications,and all Insurance Binders are incorporated herein and made part of this Contract. -3- Total payment under this Contract shall not exceed the Purchase Order issued for the requested individual assignments. This Contract is expressly subject to and contingent upon an appropriation of funds. -4- The TOWN agrees to use best efforts to pay for services within thirty (30) days of receiving an invoice,so long as all services provided are sufficiently detailed in the invoice,and that the invoice has filed with the contracting department.Any payment under this Contract shall not constitute or be deemed a waiver, relinquishment, release, or abandonment of any claim which the TOWN may have against the ENGINEER for breach of this Contract. -5- The ENGINEER agrees that no obligation shall be considered to have incurred under this CONTRACT"unless and until a purchase order shall have been duly issued and approved. And further, that the obligation incurred shall be limited to the amount set forth in purchase order or purchase orders duly issued and approved. -6- Such services under this Contract will be performed as expeditiously as possible consistent with the industry standard of care. The ENGINEER states that it is qualified, and is in all relevant aspects, in good standing. The ENGINEER certifies that performance under this Contract will meet ethical business standards and good stewardship of taxpayer and public funding to prevent waste or abuse. The ENGINEER shall commence work promptly upon execution of this Agreement and shall prosecute and complete the work regularly, diligently, and uninterruptedly at such a rate as will ensure completion in a timely manner. The ENGINEER shall use their best reasonable skills and attention, which shall not be less than such state of skill and attention generally rendered by the ENGINEER/design professional for projects similar to this Project in scope, difficulty and location. Consistent with the referenced standard of care, the ENGINEER shall be responsible for the professional and technical accuracy for all work or services furnished by him or his consultants and subcontractors. The ENGINEER shall perform his work under this Agreement in such a competent and professional manner that detail checking and reviewing by the TOWN shall not be necessary. All consultants must be registered and licensed in their respective disciplines if registration and licensor are required under the applicable provisions of Massachusetts law. The ENGINEER and all consultants and subcontractors shall conform their work and services to any guidelines, standards and regulations of any governmental authority applicable to the type of work or services covered by this Agreement. Neither the TOWN's review, approval or acceptance of any of the work or services performed shall be construed to operate as a waiver of any rights under the Agreement or any cause of action arising out of the performance of the Agreement. 2 -7- The ENGINEER shall produce One (1) reproducible copy of all drawings, plans, specifications and other documents prepared bythe ENGINEER which shall become the property of the TOWN upon payment in full therefor to the ENGINEER. Ownership of stamped drawings and specifications shall not include the ENGINEER's certification or stamp. Any re-use of such documents without the ENGINEER's written verification of suitability for the specific purpose intended shall be without liability or legal exposure to the ENGINEER or to the ENGINEER's independent professional associates,subcontractors or consultants. Distribution or submission to meet official regulatory requirements or for other purposes in connection with the Project is not to be construed as an act in derogation of the ENGINEER's rights under this Agreement. -8- The TOWN shall furnish to the ENGINEER available surveys, data and documents relating to the area which is the subject of the Scope of Work. All such information, including that relating to subsurface and other conditions, natural phenomena,existing pipes,and other structures is from the best sources at present available to the TOWN. All such information is furnished only for the information and convenience of the ENGINEER and is not guaranteed. It is agreed and understood that the TOWN does not warrant or guarantee that the subsurface or other conditions, natural phenomena, existing pipes, or other structures will be the same as those indicated in the information furnished, and the ENGINEER must satisfy himself as to the correctness of such information. If, in the opinion of the ENGINEER, such information is inadequate,the ENGINEER may request the TOWN's approval to verify such information through the use of consultants or additional exploration. In no case shall the ENGINEER commence such work'without the TOWN's prior written consent. Such work shall be compensated as agreed upon by TOWN and ENGINEER. -9- The ENGINEERshall give its personal attention constantly to the faithful performance ofthework and shall keep the same under its personal control and shall not assign nor sublet the work or any part thereof without the previous written consent of the TOWN and shall not, either legally or equitably, assign any of the monies payable under this Agreement or its claim thereto unless by and with the written consent of the TOWN. The ENGINEER shall not assign or delegate, in whole or in part or otherwise transfer any liability, responsibility,obligation,duty or interest under this Contract without the written approval of the TOWN. Any authorized subcontract entered into by the ENGINEER for the purposes of fulfilling the obligations under this Contract must be consistent with and subject to the provisions of this Contract. Subcontracts will not relieve or discharge the ENGINEER from any duty, obligation, responsibility or liability arising under this Contract. The TOWN is entitled to copies of all 3 subcontracts and shall not be bound by any provisions contained in a subcontract to which it is not a party. -10- The undersigned certifies under penalties of perjury that this bid or proposal has been made and submitted in good faith and without collusion or fraud with any other person, and in full conformity with MGL c.268A. As used in this certification, the word "person" shall mean any natural person,business, partnership,corporation, union,committee,club or other organization, entity, or group of individuals. -il- It is further agreed by the ENGINEER that, in the event the TOWN is sued in a court of law or equity, or demand is made upon the TOWN for payment of any damages arising out of the ENGINEER'S performance or non-performance of this Contract, then the ENGINEER, without reservation, shall indemnify and hold harmless the TOWN against any and all claims arising out of the ENGINEER'S negligent performance or non-performance of the Agreement. To the full extent permitted by law, no official, employee, agent or representative of the TOWN of North Andover shall be individually or personally liable on any obligation of the TOWN under this Contract. -12- It is further agreed that the TOWN may terminate this Agreement without cause, upon fourteen (14) days'written notice to the other party,sent by certified mail, to the usual place of business of the other party. The TOWN may also terminate this Agreement at any time for cause.To the full extent permitted by law, no official, employee, agent, or representative of the TOWN shall be individually or personally liable on any obligation of the TOWN under this contract. -13- It is understood and agreed by the TOWN and the ENGINEER that a Contract Performance Record Form must be completed on this contract by the Department Head or his designee who is supervising this contract,and such Contract Performance Record Form must be submitted to the TOWN Manager, TOWN Accountant, and Purchasing Agent prior to release of final payment under this contract. If requested by the ENGINEER a copy of the Contract Performance Record Form shall be furnished to the ENGINEER. -14- The ENGINEER certifies that any and all taxes and municipal fees due and owing to the TOWN of North Andover have been paid in full. 4 -15- This Contract is subject to all laws of the Commonwealth of Massachusetts, federal, state, and local, which are applicable to this contract, and services provided to a public entity; and it is presumed that the ENGINEER is cognizant thereof. Any and all proceedings or actions.relating to the subject matter herein shall be brought and maintained in the courts of the Commonwealth, which shall have exclusive jurisdiction thereof.This paragraph shall not be construed to limit any other legal rights of the parties. -16- The ENGINEER shall at all times during the Contract maintain in full force and effect Employer's Liability,Worker's Compensation (MGL c.152), Public Liability, and Property Damage Insurance, including contractual liability under the Commercial General Liability coverage pursuant to standard ISO policy form CG 00 01 language coverage. All insurance shall be for policy limits acceptable to the TOWN; all required insurance shall be certified by a duly authorized representative of the insurers on the "M1IA" or "ACORD" Certificate of Insurance form (incorporated into and made a part of this agreement); and before commencement of work hereunder the ENGINEER agrees to furnish the TOWN with certificate(s) of insurance or other evidence satisfactory to the TOWN. The certificates shall contain the following express obligations: "In the event of cancellation of a policy affecting the certificate holder, thirty (30) days prior written notice will be given the certificate holder. Where notice is not provided by ENGINEER's insurer, the notice will be provided by the ENGINEER." The TOWN shall be named as an additional insured under each policy or policies, except Workers' Compensation. For the purpose of the Contract, the ENGINEER shall carry the following types of insurance in at least the limits specified below. • Workers' Compensation--the required statutory amount • Employer's Liability—$500,000 • Bodily Injury& Property Damage Liability Except Automobile—$500,000 0 Automobile Bodily Injury&Property Damage Liability—$1,000,000 combined single limit for each accident. Excess Umbrella Liability—$1,000,000 for each occurrence The coverage shall be in force from the time of the agreement to the date when all the construction work for the Project is completed and accepted by the TOWN. If, however,the policy is a claims made policy, it shall remain in force for a period of three (3)years after completion. -17- She ENGINEER will carry out the obligations of this Contract in full compliance with all of the requirements imposed by or pursuant to General Laws c.15113 (Law Against Discrimination) and 5 any executive orders, rules, regulations, and requirements of the Commonwealth of Massachusetts as they may from time to time be amended. The ENGINEER shall comply with all federal and state laws, rules and regulations promoting fair employment practices or prohibiting employment discrimination and unfair labor practices and shall not discriminate in the hiring of any applicant for employment nor shall any qualified employee be demoted,discharged or otherwise subject to discrimination in the tenure, position, promotional opportunities, wages, benefits or terms and conditions of their employment, because of race, color, national origin, ancestry, age, sex, religion, disability, handicap, sexual orientation or for exercising any rights afforded by law. • -18- The ENGINEER will carry out the obligations of this Contract in full compliance with all of the requirements imposed by or pursuant to General Laws c.151, §1, et seq. (Minimum Wage Law) and any executive orders, rules, regulations, and requirements of the Commonwealth of Massachusetts as they may from time to time be amended. If applicable, the ENGINEER will at all times comply with the wage rates as determined by the Commissioner of the Department of Labor and Industries, under the provisions of General Laws c149, §§26 to 27D (Prevailing Wage Law), as shall be in force and as amended. The ENGINEER will, in addition to any other submissions required by the Prevailing Wage Law,submit certified weekly payrolls to the TOWN with the information described in General Laws c149, §2713. -19- At any time during normal business hours, and as often as the TOWN may deem it reasonably necessary, there shall be available in the office of the ENGINEER for the purpose of audit, examination, and/or to make excerpts or transcript all records, contracts, invoices, materials, payrolls, records of personnel, conditions of employment and other data relating to all matters covered by this Agreement. -20- This instrument, together with its endorsed supplements, and the other components of the contract documents, constitutes the entire contract between the parties, with no agreements otherthan those incorporated herein.AnyAmendments to this Contract must be made in writing and executed by all signatories to the original Contract, prior to the effective date of the amendment. -21- Any notice permitted or required under the provisions of this Contract to be given or served by either of the parties hereto upon the other party hereto shall be in writing and signed in the name or on the behalf of the party-giving or serving the same. Notice shall be deemed to have been 6 received at the time of actual service or three (3) business days after the date of a certified or registered mailing properly addressed. Notice to the ENGINEER shall be deemed sufficient if sent to the address set forth in the Contract and to the TOWN of North Andover by being sent to the TOWN Manager,TOWN Hall, 120 Main Street, North Andover, Massachusetts 01845. 22 Neither party shall be responsible or liable to the other for special, indirect, or consequential damages. The total aggregate liability of the ENGINEER to the TOWN of North Andover or anyone claiming through the TOWN of North Andover for any and all claims whatsoever arising out of this Agreement shall not exceed the total applicable insurance proceeds paid to Consultant by its insurers up to the amount of the minimum specified insurance policy limits set forth in this Agreement. IN 0TNES5 WHEREOF the parties have hereto and to one other identical instrument set forth their hands the day and year first above written, THE TOWN THE ENGINEER Department Head Woodard & Curran, Inc. Date: Date: 10/01/2026 Kenneth Carlson, Vice President Melissa Murphy-Rodrigues by: Print Name &Title TOWN Manager Date: Date: 10/01/2026 Federal Identification No.:. 0 1-0363222 7 APPROVED AS TO FORM: Christine P.O'Connor,TOWN Counsel Date CERTIFICATION AS TO AVAILABILITY OF FUNDS: TOWN Accountant Date ex 8 CERTIFICATIONS CERTIFICATE OF NON-COLLUSION The undersigned certifies under penalties of perjury that our bid or proposal has been made and submitted in good faith and without collusion or fraud with any other person. As used in this certification, the word "person" shall mean natural person, business, partnership, corporation, committee, union, club or other organization, entity, or group of individuals. Signature Date 10/ 1/2026 Kenneth Carlson, Vice President Woodard & Curran, Inc. Print Name &Title Company Name CERTIFICATE OF TAX COMPLIANCE Pursuant to Chapter 62C of the Massachusetts General Laws, Section 49A (b), I Kenneth Carlson authorized signatory for Woodard &Curran Inc. Name of individual Name of ENGINEER do hereby certify under the pains and penalties of perjury that said ENGINEER has complied with all laws of the Commonwealth of Massachusetts, and the TOWN of North Andover, relating to taxes, permit or other fees, reporting of employees and ENGINEERS, and withholding and remitting child support. IR���� � .. 10/01/2026 Signature Date 9 CERTIFICATE OF VOTE At a duly authorized meeting the Board of Directors of the Woodard &Curran, Inc. held on May 10, 2023 it was VOTED,THAT Kenneth Carlson Vice President (Name) (Officer) of Woodard & Curran, Inc. be and hereby is authorized to execute contracts and bens in the name and on behalf of said Woodard &Curran, Inc.,and affix its reFpeFatesea.heFer; and such execution of any contract or obligation in the name of Woodard & Curran, Inc._on its behalf by such officer under seal of Woodard & Curran, Inc., shall be valid and binding upon Woodard & Curran, Inc. I hereby certify that I am the clerk of the above named Woodard &Curran, Inc.and that. Kenneth Carlson is the duly elected officer as above of said Woodard &Curran, Inc., and that the above vote has not been amended or rescinded and remains in full force and effect as the date of this contract. (Date) (Clerk) 10 ATTACHMENT A-SCOPE OF WORK AND BUDGET 11 Attachment A Town of North Andover, Massachusetts Water and Wastewater Engineering Support Services Woodard & Curran October 1, 2026 Scope of Work and Budget SCADA Engineering Services For SCADA Server Upgrade, Remote Access, and Equipment PROJECT DESCRIPTION The Town of North Andover would like to include new SCADA iFIX servers as part of the Phase 1 SCADA System Upgrades.This proposal includes configuration and startup support for the implementation of two new iFIX servers for the North Andover Water Treatment Plant to support the WW SCADA Upgrade work. Additionally, this task order amendment includes additional equipment costs and scope needed for installation for the Radio Master at the Water Treatment Plant and the Radio Repeater at the Bear Hill site including a security fence around the radio tower. The scope of this effort includes procurement and configuration of the SCADA server hardware, licensing for existing iFIX software with SCADASync redundancy, replacement of the legacy alarm dialing system, and implementation of a secure remote access solution.The services described herein are intended to improve system reliability, maintainability, and cybersecurity posture. SCOPE OF SERVICES Task 1 -Wastewater SCADA iFIX Servers Task 1.1 Project Administration and Procurement Services Woodard 0 Participate in one project coordination meeting. & Curran 0 Specify, procure, and deliver two (2) new Workstation class PCs to function as the new SCADA Servers. PCs will include new keyboards, monitors, and UPS. 0 Specify and procure SMS And Voice alarm dialer hardware. * Procure license upgrades for existing iFIX software for one (1) Primary SCADA server, and one (1) Backup SCADA Server, with SCADASync. 0 Procure license for Topview alarm dialer software. 0 Procure one (1) license for Microsoft Office, to be installed on the Primary SCADA server. Task 1.2 - Programming • PC Configuration • Set up Windows on new PCs, configuring auto login. • Installation of MS Office on the Primary PC • iFIX Configuration * Installation of iFIX software on both PCs; Primary PC will be the development node, Backup PC will be the runtime node. * Retrieve a backup of the existing iFIX server configuration and alarm dialer configuration, migrate to new system. * Configure and test iFIX SCADA Sync redundancy and server failover. * Configure Proficy Historian on both PCs, import all tags from legacy Historian. * Configure I drivers on both PCs for connection to all PLCs * Apply licenses to all iFIX Software. • Alarm Software Configuration o Installation of Topview software on the Primary PC. .......... Town of North Andover (10000134_01) 2 Woodard&Curran, hc. SCADA PC Upgrade October 1, 2026 o Installation of the Topview Alarm viewer software on both PCs. o Configure all existing dialout alarms in Topview. o Configure SMS modem and test connection with Topview Woodard o Configure Voice modem and test connection with Topview & Curran o Provide recommendations to WTP to help them procure a SIM card for the SMS Modem. o Apply Licenses to all Topview software. Task 1.3 —Startup • Delivery of new SCADA PCs and associated hardware to the WTP. • Connect new PCs to the SCADA existing SCADA network. • Connect Voice dialer to Client's phone system, coordinate connection with Client's IT department. Send test calls to confirm functionality. • Connect new SMS modem to Client's network. Install SIM card procured by Client, Send test SMS to confirm functionality. • Test communications between PI-Cs and new SCADA PCs. • Migrate one (1)year of historical data from old iFIX system to new. This assumes that the old RX system was using Proficy Historian. If the old system was not using Proficy Historian, this is not in scope. • Test SCADASync failover from Primary to Backup Server and back. • Configure all Client's Operators/Supervisors in Topview Software • Conduct an end-to-end test of the alarm dialer system: * Initiate a test alarm from a PLC tag. * Demonstrate delay before dialout, and alarm escalation. * Demonstrate successful Voice alert and alarm acknowledgement from voice through to RX * Demonstrate successful SMS alert and alarm acknowledgement from SMS through to RX .......... Town of North Andover(10000134,01) 3 Woodard &Curran, hic SCADA P('Upgrade October 1.2026 Task 1.4—Documentation and Training • Provide final backup iFIX and Topview configurations in electronic format. • Provide up to four(4) hours training to the Town's operations and maintenance staff. Woodard &Curran Task 2— Remote Access Implementation Woodard &Curran has developed a remote access solution that aligns with the latest cybersecurity practices and standards set by leading authorities and experts, such as Instrument Society of America (ISA) IEC-62443, National Institute of Standards and Technology (NIST) MIST 800-82, and the Cybersecurity& Infrastructure Security Agency(CISA). At a high level the architecture improves the security posture of a utilities' SCADA system in these key areas (see typical remote access illustration provided): • The system will be implemented utilizing next-generation firewalls (NGFW). NGFWs offer advanced threat detection and inspection features allowing the firewall to both block unwanted data while also scanning and inspecting the data that is allowed to pass through the firewall. NGFWs also implement subscription services that allow the firewall to constantly update its threat and virus definitions against the latest tactics being utilized by bad actors. • Access to the system will be facilitated through a zero trust network access (ZTNA) architecture, implementing centralized user accounts with multifactor authentication (MFA) that are individual to each user accessing the system. A ZTNA solution offers additional security features when compared to a virtual private network (VPN) tunnel. These advantages include more granular access control for individual users, user session recording as well as the ability to restrict individual users or vendor access to a specific schedule or require an approval process before they are granted access. • A demilitarized zone (DMZ) will be implemented. The DMZ will act as a buffer between the untrusted public network and the internal critical SCADA system network. Traffic leaving the SCADA system will terminate in the DMZ. Traffic entering the system will also terminate in the DMZ. This architecture ensures that the public network is never directly communicating with the internal SCADA network and vice versa the internal SCADA network is never directly communicating with the external public network. • The system incorporates network segmentation. Network segmentation is the process of grouping equipment into smaller networks that are logically isolated from other networks. Equipment or processes that are required to communicate with a device in a different network segment will pass through Town of North Andover(10000134 01) 4 Woodard&Curran,Inc. SCADA PC Upgrade October 1,2026 an enforcement boundary (a firewall). The enforcement boundary is programmed with a set of rules only allowing specific devices to pass specific data across network segments. If a breach were to occur, network 19� segmentation greatly increases the chances that the intrusion will be contained within a single network segment and avoid having the attacker gain access to Woodard the entire system. &Curran Typical Remote Access Illustration OuNde Untrusted Network DMZ w. � L DMZ Proxy SCADALAN �261`A PLC SCADA Switch Access SCADA 1 SCADA 2 Contioller, Town of North Andover(10000134_01) 5 Woodarci&Curran, Mc, SCADA PC Upgrade October 1,2026 Woodard & Curran's work will include investigating the existing network, specifying and procuring materials, configuring and installing the security equipment, as well as providing network drawings and training. Woodard The following will be included for remote access implementation: &Curran Firewall • Qty: 1 — Next Generation Firewall (NGFW)Appliance • Qty: 1 —One Year Firewall Threat Protection License • Qty: 1 --One Year Firewall Support License NOTE: This scope includes one-year subscription licenses for firewalls. Future subscriptions are the responsibility of the client. Network Switch • Qty: 2— DMZ Switch—Cisco Catalyst Network Rack • 6U Wall Mount Network Rack with power strip DMZ Qty: 1 —DMZ PC: Proxy Virtual Machine & Device Access Virtual Machine • Qty: 2 -VNC server software • 1 year Okta subscription for up to 5 users • 1 year Cyolo ZTNA subscription for up to 5 users Training • Up to two (2) hours of training with staff to download required applications on their smart devices and basic training on how to remote into the facility and verify that their new credentials are working properly. Task 3 —Additional Equipment Costs and Planning Board Coordination Equipment costs for the Radio Repeater Tower have increased since the original task order. This task includes budget to cover the additional equipment costs and add security fencing and anti-climb panels around the Bear Hill radio repeater tower. Woodard & Curran will work with a subcontractor to install a 6 ft black vinyl-coated Town of North Andover(10000134_01) 6 Woodard&Curran, Inc. SCADA PC Upgrade October 1,2026 chain link security fence with a three barbed wire top extension. The fence will have one locking pedestrian entrance gate. The fence will be installed in 16' X16' square configuration. The anti-climb panels are 10 feet tall and bolt into the tower at the base. Woodard Woodard&Curran will work with the Town of North Andover Planning Board to obtain an exemption for the Wireless Facility under Part 8 of the North Andover City Zoning & Curran Code. Task 4—Allowance for Site Restoration at Bear Hill This task includes an allowance for Woodard & Curran to work with a landscape contractor to restore any land at the Bear hill site that was disturbed due to the construction of the radio repeater tower. If the land is disturbed due to the concrete truck or any other heavy equipment used, the Town may direct Woodard &Curran to coordinate with a landscaping subcontractor to restore the area, This task will only be used if requested by the Town. DELIVERABLES • Programming, hardware, and integration services as outlined above. • Final backup iFIX and Topview configurations in electronic format. • Network drawings for Remote Access. • Training for OX and Remote Access; up to six (6) hours total. • Inclusion of a fence around the Bear Hill Radio Repeater tower. SCHEDULE This work is expected to take two months and extend the schedule of the Phase 1 WW SCADA Upgrade by up to one month, or end of August 2026. ............ ....... 'Town of North Andover(10000134 01) 7 Woodard&CLIMan, IrIC, SCADA PC,Upgrade October 1,2026 COMPENSATION Compensation for the Engineering Services described herein will be based upon the following budgets that are not to be exceeded without prior written authorization. Woodard & Curran Description Fee Wastewater SCADA i>FIX Server $66,500 Remote Access $23,000 Additional Equipment Costs, Fence,and $40,500 Planning Board Coordination Site Restoration Allowance $5,000 Total Project $135,000 Services will be invoiced monthly on a time and material basis in accordance with the attached terms and conditions. ASSUMPTIONS AND UNDERSTANDINGS The following assumptions and understandings apply to the scope of work and budget described herein, in addition to those assumptions and understandings described above: • Client will provide a SIM card with Unlimited SMS messages. Client will inform W&C of the carrier, carrier selection will affect the SMS modem hardware procurement. • Client will provide either an analog phone line (POTS) or assistance in connecting the Grandstream modem to a client provided VOIP phone system. • Client will provide access to the necessary facilities for W&C to perform upgrade services. Client will also provide timely access to staff to coordinate training, and assist in testing of alarm notification via voice and SMS. • All software provided by W&C will be perpetually licensed, and provided with 1 year of support from the software provider. Ongoing Software subscription costs for support beyond 1 year will be provided by the Client. Town of North Andover(10000134_01) 8 Woodard&Curran,Inc. SCADA PC Upgrade October 1,2026 • No Reporting software installation or configuration is included in this scope as it appears that the Town does not use this software currently. If the Town would like to include reporting software, installation, and configuration, W&C can provide for an additional fee. Woodard • The existing Win911 alarm dialing software will be replaced by Topview as part of this effort. Support or parallel operation of Win911 on the new system is &Curran not included. • No changes to PLC logic are included. • Operations & Maintenance Manual development is not included in this scope. If the Town would like us to include an Operations and Maintenance Manual, W&C can provide for an additional fee. • This proposal does not include software and/or subscriptions associated with new devices beyond the first year. Town of North Andover(10000134 01) 9 Woodard&Curran, Inc. SCADA PC Upgrade October 1,2026 ATTACEN ENT B-RATE TABLE 12 Woodard &Cur,ran Rate Schedule Public 20,26 Administrative $125 Drafter/Project Assistant/Technician 1 $140 Graphic Artist/Project Specialist $150 Graphics Manager/Senior Project Assistant $160 Designer 1 /Geologist 1 /GIS Analyst 1 /Planner 1/Scientist 1 /Technician 2 $165 Designer 2/Engineer 1/Geologist 2/GIS Analyst 2/Scientist 2/Specifications Manager $170 Planner 2/Technical Specialist 1 /Technician 3 $175 Contract Document Specialist/Geologist 3/GIS Analyst 3/Scientist 3 $180 Designer 3/Engineer 2/Plant Manager/Procurement Specialist/Programmer 1 $190 Project Geologist 1 /Project Scientist 1 /Technical Specialist 2 Engineer 3/GLS Solutions Analyst/Planner 3/Programmer 2/Technical Specialist 3 $205 Programmer 3/Project Geologist 2 1 Project Scientist 2/Project Tech Specialist 1 $210 Senior Designer Project Electrical Engineer I/Project Engineer 1 /Project Planner 1 $215 Project Engineer 2/Project Planner 2/Project Tech Specialist 2/Senior Project Geologist $225 Senior Project Scientist/Senior Resident Project Representative Senior Cost Estimator/Senior Planner $230 GlS Manager/Project Manager I /Technical Manager 1 $240 Construction Manager/Project Manager 2/Technical Manager 2 $260 Program Manager $265 Senior Project Manager/Senior Technical Manager $270 Senior Consultant/Senior Delivery Leader/Senior Program Leader Senior Technical Leader $275 Principal in Charge/Senior Technical Consultant $280 National Technical Leader/Senior Practice Leader $290 Travel $030 mile Other Direct Costs At Cost Plus 15% SubcorisLiltants/Subcoiitractors At Cost Plus 15% NOTES Mileage rate will change as the federal allowable rate is modified. 11%is rate schedWe is confidenlial and for rustornor lnternA use only, Woodard&Cuirran reveive,s tho right to adjust b0fisrg rates annuMly, Page I Vf I