Loading...
HomeMy WebLinkAboutFire Station 3_Intro Letter & Checklist - Correspondence - 0 BERRY STREET SACCOCC10 & ASSOCIATL-S ARCHITECTS August 19, 2026 Town of North Andover Zoning Board of Appeals Attn; Scott Vandewalle Building Commissioner& Zoning Enforcement Officer 120 Main Street North Andover,MA 01845 RE: Town of North Andover-North Andover Fire Station 3 Special Permit Application Assessor Map 108,Parcel 10 Berry Street/Turnpike Street North Andover,MA 01845 Mr.Vandewalle and Board Members, On behalf of the Town of North Andover, we would like to present the proposed Fire Station 3 to the Zoning Board of Appeals, for approval of a special permit for building use. The proposed site is identified by the Assessor's map Plat 108, Parcel 10. The parcel is approximately 21,300 acres and situated primarily in an Industrial district(13)zone except for the western most end of the property which is identified as Residential district (R2). The site, which is owned by the town, is currently a combination of wetland,vegetation and open space with recreational fields located to the North/East part of the site(Sharpners Pond Fields), These fields will not be disturbed and the path that connects to the field from Berry Street will be addressed by the Town under a separate project. The proposed Fire Station will be situated within this R2 zone at the corner of Berry Street and Turnpike Street(Route 114),which will give emergency response teams the ability to provide better coverage and quicker response times to the southern end of North Andover. The proposed building is a one-story, 10,000 sf building(including a mezzanine at the apparatus bay),type V13 construction.The highest roof ridge of the building is 34'-0"A.F.F.The 5 bay Apparatus building will be a pre-engineered steel structure(6300so and the remaining portion of the building which will provide support space for the firefighters will be wood framed construction and designed to meet the 2025 Massachusetts energy stretch code (225 CMR 23.00). The building will be fit out with full mechanical,electrical,plumbing, fire protection and fire alarm systems.The Station will have a communications tower and antenna mounted to the building which will not exceed the 65' height allowance per Zoning Bylaw Chapter 195; Article 7.4.13 &D. Per Zoning Bylaw Chapter 195; Article 4.2.J; Public/Service buildings may be allowed in the R2 zone by special permit. This proposed development meets all other zoning requirements.The only relief that we are requesting is for Special Permit for Building Use. Included with this application is the narrative for site design by Level Design Group(LDG) (07/22/26)and Wetlands report by Pare Engineering(11/07/25),which further explains the site conditions,wetlands and support for the request of zoning approval. This project is also currently under review with the Planning Review Board and Conservation Commission, 1005 Park Avenue, Cranston, R1 02910 w "r 401.942.7970 r 401.942.7975 - www.sa-at-chitects.com Enclosed,please find the following: 1. Checklist for application 2. (12) 11x17 copies of permit application package 3.Full size copy of site plans 4. Certified Abutter List and required abutter notification mailing envelopes 5.USB Drive with PDF Copies of all submission material. Municipal Charges form and associated Special Permit filing fees have not been included with this package, as this is a Town-owner and funded project. Saccoccio&Associates has also been instructed not to include postage for the abutter notifications, as the Town will provide required postage for notifications. If there are any questions about the permit application or if additional copies of the submission are needed,please do not hesitate to ask. Best Rgards, 101 Katie iNanager, Hamel Project Saccoccio&Associate Architects 1085 Park AvenUe, Cranston, RI 02910 w T 401.942,7970 F 401.941.79'75 www.sa•archltects,conn